HEADTOME: A Hybrid Emission Tomograph for Single Photon and Positron Emission Imaging of the Brain
The DOI matches its Crossref record.
Abstract
A hybrid emission tomograph, combining a single photon emission tomograph (SET) and a positron emission tomograph (PET) in one system, has been developed. The system was designed as a high speed, high accuracy neurological tomograph capable of measuring cerebral blood flow with 133Xe, cerebral glucose metabolism with 18F-fluorodeoxyglucose, etc. The detector array consists of 64 Nal crystals in a 42 cm diameter circle. Two collimator sets can slide axially on the inner face of the crystal ring to change from SET to PET imaging. The SET collimator consists of 64 units, each containing a 2 mm thick, 30 × 70 mm tungsten fin plus five sub-fins. All the fins are driven synchronously to swing back and forth over a 60° angle, covering an image field of 21 cm diameter. Linear sampling is selectable from 2.5 to 20 mm by changing the ring rotation increments. Slice thickness is also selectable with interchangeable slice collimators of 16, 20, and 24 mm gap. SET performance with 99mTc showed a resolution of 7.5 and 10 mm full width at half maximum (FWHM) at the periphery and at the center, respectively. System sensitivity with the 20 mm slice collimator is 10,000 counts/sec/μCi/ml for a 20 cm diameter uniform solution of 133Xe and 21,000 counts/sec/μCi/ml for 99mTc. The fastest scan time is 2 sec and provides a spatial resolution of 20 mm FWHM, which is sufficient for dynamic studies of 133Xe clearance. The PET collimator consists of two doughnut shaped lead plates that define the slice plane. The gap is selectable at 12, 20, and 28 mm. Linear sampling in PET is about 20 mm with a stationary ring, 10 mm employing the ring rotation, and 3 mm with the ring wobble. The wobble diameter is 7.3 mm. The PET resolution with a S8Ga line source and a nine point wobble is 11 mm FWHM at the center and 13 mm at a 10 cm radius. System sensitivities were 7,000, 20,000, and 30,000 true events per μCi/ml for 12, 20, and 28 mm slice gap, respectively. Presently, the system is under clinical use for cerebral blood flow studies using 133Xe inhalation or 8lmKr intracarotid continuous infusion, and for blood-brain barrier studies using 99mTeO4 or 68Ga-EDTA, and has yielded many fruitful results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Study of Cerebral Function with Positron Computed Tomography
Phelps, M. E., Mazziotta, J. C., & Huang, S.-C. (1982) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1982.14 · Cited by 378
The temporal variant of frontotemporal dementia
Edwards-Lee, T. (1997) · Brain · doi:10.1093/brain/120.6.1027 · Cited by 373
An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT
Daube-Witherspoon, M. E., & Muehllehner, G. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307748 · Cited by 237
Cerebral Blood Flow Correlates of Apathy in Alzheimer Disease
Craig, A. H., Cummings, J. L., Fairbanks, L., Itti, L., Miller, B. L., Li, J., & Mena, I. (1996) · Archives of Neurology · doi:10.1001/archneur.1996.00550110056012 · Cited by 223
Metadata
- Authors
- Kanno, I., Uemura, K., Miura, S., & Miura, Y.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1981-04
- Volume
- 5
- Issue
- 2
- Pages
- 216-226
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1973533028
- Cited by
- 75
- References
- 0
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HEADTOME: A Hybrid Emission Tomograph for Single Photon and Positron Emission Imaging of the Brain. https://app.cochat.ai/papers/10.1097/00004728-198104000-00013
- The paper
- Kanno, I., Uemura, K., Miura, S., & Miura, Y. (1981). HEADTOME: A Hybrid Emission Tomograph for Single Photon and Positron Emission Imaging of the Brain. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198104000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.