Abstract

We designed and built a positron emission transverse tomograph (PETT VI), designed specifically for fast dynamic studies in the human brain, and for cardiac studies in experimental animals. The scintillation detectors incorporated into this device are fitted with cesium fluoride crystals. Cesium fluoride was selected for this purpose because its short fluoresence decay allows the use of a short coincidence resolving time with a concomitant reduction of unwanted random coincidences. PETT VI utilizes four rings of 72 detectors simultaneously yielding seven tomographic sections. The system can be operated in either a low or high resolution mode with intrinsic geometrical resolutions in the plane of section of 7.1 to 11.7 mm full width at half maximum (FWHM), for a slice thickness with a resolution at the center of 13.9 mm FWHM. The maximum sensitivity of the system for seven slices in the low resolution mode is 322,000 cps/μCi/cc in a 20 cm diameter phantom. The contribution of random coincidences before subtraction in PETT VI was found to be approximately 14% of the counts in the phantom image with a source of approximately 3.5 mCi of a positron emitting radionuclide dispersed in a 20 cm diameter tissue equivalent phantom with a concentration of 1 μCi/cc. The short coincidence resolving time of the system permits rapid data acquisition for attenuation corrections and clinical dynamic studies with data acquisition times of less than a minute.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198202000-00021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 132

Metadata

Authors
Ter-Pogossian, M. M., Ficke, D. C., Hood, J. T., Yamamoto, M., & Mullani, N. A.
Venue
Journal of Computer Assisted Tomography
Published
1982-02
Volume
6
Issue
1
Pages
125-133
ISSN
0363-8715 (ISSN-L)
OpenAlex
W4293858637
Cited by
132
References
0
FWCI
16.19
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: PETT VI: A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors. https://app.cochat.ai/papers/10.1097/00004728-198202000-00021
The paper
Ter-Pogossian, M. M., Ficke, D. C., Hood, J. T., Yamamoto, M., & Mullani, N. A. (1982). PETT VI: A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198202000-00021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.