PETT VI: A Positron Emission Tomograph Utilizing Cesium Fluoride Scintillation Detectors
The DOI matches its Crossref record.
Abstract
We designed and built a positron emission transverse tomograph (PETT VI), designed specifically for fast dynamic studies in the human brain, and for cardiac studies in experimental animals. The scintillation detectors incorporated into this device are fitted with cesium fluoride crystals. Cesium fluoride was selected for this purpose because its short fluoresence decay allows the use of a short coincidence resolving time with a concomitant reduction of unwanted random coincidences. PETT VI utilizes four rings of 72 detectors simultaneously yielding seven tomographic sections. The system can be operated in either a low or high resolution mode with intrinsic geometrical resolutions in the plane of section of 7.1 to 11.7 mm full width at half maximum (FWHM), for a slice thickness with a resolution at the center of 13.9 mm FWHM. The maximum sensitivity of the system for seven slices in the low resolution mode is 322,000 cps/μCi/cc in a 20 cm diameter phantom. The contribution of random coincidences before subtraction in PETT VI was found to be approximately 14% of the counts in the phantom image with a source of approximately 3.5 mCi of a positron emitting radionuclide dispersed in a 20 cm diameter tissue equivalent phantom with a concentration of 1 μCi/cc. The short coincidence resolving time of the system permits rapid data acquisition for attenuation corrections and clinical dynamic studies with data acquisition times of less than a minute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
Mintun, M. A., Raichle, M. E., Kilbourn, M. R., Wooten, G. F., & Welch, M. J. (1984) · Annals of Neurology · doi:10.1002/ana.410150302 · Cited by 955
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Bergmann, S. R., Herrero, P., Markham, J., Weinheimer, C. J., & Walsh, M. N. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90105-8 · Cited by 439
Powers, W. J., Grubb, R. L., Darriet, D., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.89 · Cited by 425
Mapping Human Brain Monoamine Oxidase A and B with11C-Labeled Suicide Inactivators and PET
Fowler, J. S., MacGregor, R. R., Wolf, A. P., Arnett, C. D., Dewey, S. L., Schlyer, D., Christman, D., Logan, J., Smith, M., Sachs, H., et al. (1987) · Science · doi:10.1126/science.3099392 · Cited by 391
Fiez, J. A., Balota, D. A., Raichle, M. E., & Petersen, S. E. (1999) · Neuron · doi:10.1016/s0896-6273(00)80833-8 · Cited by 390
A focal brain abnormality in panic disorder, a severe form of anxiety
Reiman, E. M., Raichle, M. E., Butler, F. K., Herscovitch, P., & Robins, E. (1984) · Nature · doi:10.1038/310683a0 · Cited by 320
Positron emission tomography after MPTP: observations relating to the cause of Parkinson's disease
Calne, D. B., Langston, J. W., Martin, W. R. W., Stoessl, A. J., Ruth, T. J., Adam, M. J., Pate, B. D., & Schulzer, M. (1985) · Nature · doi:10.1038/317246a0 · Cited by 313
Fiez, J. A., Raichle, M. E., Miezin, F. M., Petersen, S. E., Tallal, P., & Katz, W. F. (1995) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1995.7.3.357 · Cited by 311
Update on time-of-flight PET imaging
Surti, S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.145029 · Cited by 303
The application of positron emission tomography to the study of panic disorder
(1986) · American Journal of Psychiatry · doi:10.1176/ajp.143.4.469 · Cited by 290
Tonotopic organization in human auditory cortex revealed by positron emission tomography
Lauter, J. L., Herscovitch, P., Formby, C., & Raichle, M. E. (1985) · Hearing Research · doi:10.1016/0378-5955(85)90024-3 · Cited by 272
Neuroanatomical Correlates of Anticipatory Anxiety
Reiman, E. M., Fusselman, M. J., Fox, P. T., & Raichle, M. E. (1989) · Science · doi:10.1126/science.2784226 · Cited by 261
Dopamine blockade and clinical response: evidence for two biological subgroups of schizophrenia
(1989) · American Journal of Psychiatry · doi:10.1176/ajp.146.7.905 · Cited by 258
Shulman, G. L., Corbetta, M., Buckner, R. L., Fiez, J. A., Miezin, F. M., Raichle, M. E., & Petersen, S. E. (1997) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1997.9.5.624 · Cited by 251
Fox, P. T., Mintun, M. A., Raichle, M. E., & Herscovitch, P. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.49 · Cited by 242
Evans, A. C., Beil, C., Marrett, S., Thompson, C. J., & Hakim, A. (1988) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1988.92 · Cited by 232
Herscovitch, P., Raichle, M. E., Kilbourn, M. R., & Welch, M. J. (1987) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1987.102 · Cited by 222
Mukherjee, J., Yang, Z.-Y., Das, M. K., & Brown, T. (1995) · Nuclear Medicine and Biology · doi:10.1016/0969-8051(94)00117-3 · Cited by 219
Cerebral Blood Volume Measured with Inhaled C15O and Positron Emission Tomography
Martin, W. R. W., Powers, W. J., & Raichle, M. E. (1987) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1987.85 · Cited by 193
Bergmann, S. R., Lerch, R. A., Fox, K. A. A., Ludbrook, P. A., Welch, M. J., Ter-Pogossian, M. M., & Sobel, B. E. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90338-2 · Cited by 192
Self-citationAdvances in time-of-flight PET
Surti, S., & Karp, J. S. (2016) · Physica Medica · doi:10.1016/j.ejmp.2015.12.007 · Cited by 173
“The first generation of TOF PET scanners was developed in the early 1980s at several research institutions [5–10] with a primary goal of brain and cardiac imaging with compounds tagged to shortlived radio-isotopes, such as 15O-water, 11C-acetate, and 82Rb.”
BackgroundCerebellar blood flow and metabolism in cerebral hemisphere infarction
Wayne Martin, W. R., & Raichle, M. E. (1983) · Annals of Neurology · doi:10.1002/ana.410140203 · Cited by 163
Update on latest advances in time-of-flight PET
Surti, S., & Karp, J. S. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.031 · Cited by 96
Metadata
- Authors
- Ter-Pogossian, M. M., Ficke, D. C., Hood, J. T., Yamamoto, M., & Mullani, N. A.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1982-02
- Volume
- 6
- Issue
- 1
- Pages
- 125-133
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W4293858637
- Cited by
- 132
- References
- 0
- FWCI
- 16.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.