Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 214

The DOI matches its Crossref record.

Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography

Bergström, M., Litton, J., Eriksson, L., Bohm, C., Blomqvist, G. · 1982 · Journal of Computer Assisted Tomography

Abstract

A contour-finding algorithm is described by which the object periphery is outlined in positron emission tomography (PET) scans. The positions of maximum slopes are determined in the projections. These positions are shown to correspond well to the borders of the activity region. By backprojecting these points in the projections into the image plane, the size and shape of the region of activity must be outlined. Cord lengths across this region are then determined for attenuation correction. The accuracy of the algorithm has been tested on 10 patients with both PET and computed tomography (CT) examinations. Points on the periphery of the skull, as determined with the contour-finding algorithm in PET, coincided with those determined by CT, with a standard deviation of 1.5 mm and a maximum deviation of 3.5 mm. In testing the influence of the skull bone on the PET values, it was found that ignoring the higher attenuation coefficient of bone, 5 mm thick, in the attenuation correction caused an error in the determination of activity of 11% peripherally and 6% centrally in the object. These errors could be reduced to less than 1% by increasing the assumed attenuating region by 4.5 mm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198204000-00022

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Bergström, M., Litton, J., Eriksson, L., Bohm, C., & Blomqvist, G.
Venue
Journal of Computer Assisted Tomography
Published
1982-04
Volume
6
Issue
2
Pages
365-372
ISSN
0363-8715 (ISSN-L)
OpenAlex
W1986348744
Cited by
214
References
0
FWCI
5.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography. https://app.cochat.ai/papers/10.1097/00004728-198204000-00022
The paper
Bergström, M., Litton, J., Eriksson, L., Bohm, C., & Blomqvist, G. (1982). Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission Tomography. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198204000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.