The DOI matches its Crossref record.
Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging
Abstract
Calculations of the sensitivity of the saturation recovery and inversion recovery pulse sequences used in nuclear magnetic resonance imaging show the former to be superior in discriminating between tissues with the same proton density but different T1's. Two other pulse sequences, which are combinations of the above, have also been analyzed. These have lower T1 discrimination sensitivity, but other considerations, such as self-normalization, may still make them attractive. The calculations are only valid for selective excitation pulse sequences in which the selected slice profiles are approximately rectangular, and thus a sin(bt)/t radiofrequency excitation is desirable. In order to ensure that the saturation recovery sequence gives valid results for pulse repetition times comparable to or shorter than T2, it is necessary to destroy the coherence between pulse applications. For this purpose we use a series of "spoiler" gradient pulses between pulse trains. The saturation recovery pulse sequence also has the advantage that, by the correct choice of interpulse spacing, sensitivity close to the optimum T1 discrimination can be achieved over a wide range of T1 values. This has the potential advantage to the clinician of simplifying his choice of parameters for imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Self-citationSpoiling of transverse magnetization in steady‐state sequences
Zur, Y., Wood, M. L., & Neuringer, L. J. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210210 · Cited by 306
Metadata
- Authors
- Edelstein, W. A., Bottomley, P. A., Hart, H. R., & Smith, L. S.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1983-06
- Volume
- 7
- Issue
- 3
- Pages
- 391-401
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2070818218
- Cited by
- 201
- References
- 0
- FWCI
- 23.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging. https://app.cochat.ai/papers/10.1097/00004728-198306000-00001
- The paper
- Edelstein, W. A., Bottomley, P. A., Hart, H. R., & Smith, L. S. (1983). Signal, Noise, and Contrast in Nuclear Magnetic Resonance (NMR) Imaging. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198306000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.