The DOI matches its Crossref record.
Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Abstract
Dynamic MR imaging can be used to study tissue perfusion and vascular permeability. In the present article a procedure for dynamic MR is presented, which (a) accurately resolves the fast kinetics of tissue response during and after intravenous infusion of the paramagnetic contrast medium Gd-DTPA and (b) yields a linear relationship between the measured MR signal and the Gd-DTPA concentration in the tissue. According to these features, the measured signal-time curves can be analyzed within the framework of pharmacokinetic modeling. Tissue response has been parameterized using a linear two-compartment open model, with only negligible effects of the peripheral compartment on the central compartment. The three model parameters were fitted to the signal-time data pixel by pixel, based on a set of 64 rapid SE images (SE 100/10 ms, image scan time 13 s, interscan intervals 11 s). This makes it possible to construct parameter images, whereby structures become visible that cannot be distinguished in conventional Gd-DTPA enhanced MR. As a clinical example, the approach is discussed in a case of glioblastoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationModeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Vascular normalization in Rgs5-deficient tumours promotes immune destruction
Hamzah, J., Jugold, M., Kiessling, F., Rigby, P., Manzur, M., Marti, H. H., Rabie, T., Kaden, S., Gröne, H.-J., Hämmerling, G. J., et al. (2008) · Nature · doi:10.1038/nature06868 · Cited by 564
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions
Padhani, A. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10176 · Cited by 472
Metadata
- Authors
- Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1991-07
- Volume
- 15
- Issue
- 4
- Pages
- 621-628
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2036913456
- Cited by
- 659
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging. https://app.cochat.ai/papers/10.1097/00004728-199107000-00018
- The paper
- Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991). Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199107000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.