Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
The DOI matches its Crossref record.
Abstract
Dynamic MR imaging can be used to study tissue perfusion and vascular permeability. In the present article a procedure for dynamic MR is presented, which (a) accurately resolves the fast kinetics of tissue response during and after intravenous infusion of the paramagnetic contrast medium Gd-DTPA and (b) yields a linear relationship between the measured MR signal and the Gd-DTPA concentration in the tissue. According to these features, the measured signal-time curves can be analyzed within the framework of pharmacokinetic modeling. Tissue response has been parameterized using a linear two-compartment open model, with only negligible effects of the peripheral compartment on the central compartment. The three model parameters were fitted to the signal-time data pixel by pixel, based on a set of 64 rapid SE images (SE 100/10 ms, image scan time 13 s, interscan intervals 11 s). This makes it possible to construct parameter images, whereby structures become visible that cannot be distinguished in conventional Gd-DTPA enhanced MR. As a clinical example, the approach is discussed in a case of glioblastoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationModeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Vascular normalization in Rgs5-deficient tumours promotes immune destruction
Hamzah, J., Jugold, M., Kiessling, F., Rigby, P., Manzur, M., Marti, H. H., Rabie, T., Kaden, S., Gröne, H.-J., Hämmerling, G. J., et al. (2008) · Nature · doi:10.1038/nature06868 · Cited by 564
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Dynamic contrast‐enhanced MRI in clinical oncology: Current status and future directions
Padhani, A. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10176 · Cited by 472
Functional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Heye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Quantitative Analysis of Dynamic Gd‐DTPA Enhancement in Breast Tumors Using a Permeability Model
Tofts, P. S., Berkowitz, B., & Schnall, M. D. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330416 · Cited by 399
Yankeelov, T., & Gore, J. (2007) · Current Medical Imaging Reviews · doi:10.2174/157340507780619179 · Cited by 398
Engelbrecht, M. R., Huisman, H. J., Laheij, R. J. F., Jager, G. J., van Leenders, G. J. L. H., Hulsbergen-Van De Kaa, C. A., de la Rosette, J. J. M. C. H., Blickman, J. G., & Barentsz, J. O. (2003) · Radiology · doi:10.1148/radiol.2291020200 · Cited by 380
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Pharmacokinetic Mapping of the Breast: A New Method for Dynamic MR Mammography
Hoffmann, U., Brix, G., Knopp, M. V., Heβ, T., & Lorenz, W. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330408 · Cited by 303
Self-citationOverview of Dynamic Contrast-Enhanced MRI in Prostate Cancer Diagnosis and Management
Verma, S., Turkbey, B., Muradyan, N., Rajesh, A., Cornud, F., Haider, M. A., Choyke, P. L., & Harisinghani, M. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.8510 · Cited by 301
Abou-Elkacem, L., Arns, S., Brix, G., Gremse, F., Zopf, D., Kiessling, F., & Lederle, W. (2013) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-12-1162 · Cited by 282
Self-citationDynamic contrast-enhanced MRI as a predictor of tumour response to radiotherapy
Zahra, M. A., Hollingsworth, K. G., Sala, E., Lomas, D. J., & Tan, L. T. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(06)71012-9 · Cited by 272
Mapping pathophysiological features of breast tumors by MRI at high spatial resolution
Degani, H., Gusis, V., Weinstein, D., Fields, S., & Strano, S. (1997) · Nature Medicine · doi:10.1038/nm0797-780 · Cited by 268
Pickles, M. D., Lowry, M., Manton, D. J., Gibbs, P., & Turnbull, L. W. (2005) · Breast Cancer Research and Treatment · doi:10.1007/s10549-004-5819-2 · Cited by 213
“First the model assumes that delivery of the contrast agent is not flow limited [11, 37].”
BackgroundMethodKim, S., Loevner, L. A., Quon, H., Kilger, A., Sherman, E., Weinstein, G., Chalian, A., & Poptani, H. (2010) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1817 · Cited by 190
Ewing, J. R., Knight, R. A., Nagaraja, T. N., Yee, J. S., Nagesh, V., Whitton, P. A., Li, L., & Fenstermacher, J. D. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10524 · Cited by 181
Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors
Li, K.-L., Zhu, X. P., Waterton, J., & Jackson, A. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200008)12:2<347::aid-jmri19>3.0.co;2-7 · Cited by 180
“Multicompartment pharmacokinetic models of contrast distribution are based on the assumption that contrast is evenly distributed throughout the blood volume before leakage into the extracellular space occurs (6,7,30,31).”
BackgroundMurase, K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20022 · Cited by 170
“[5] can be easily solved for the elements of B using the conventional linear least-squares (LLSQ) method, and finally K1, k2, and Vp can be easily obtained from the elements.”
MethodDynamic magnetic resonance imaging of tumor perfusion
Collins, D. J., & Padhani, A. R. (2004) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2004.1360410 · Cited by 169
“Typically, contrast agents are given either as a bolus [86] or infusion [159].”
BackgroundAssessment of Blood–Brain Barrier Disruption in Stroke
Kassner, A., & Merali, Z. (2015) · Stroke · doi:10.1161/strokeaha.115.008861 · Cited by 168
Prediction of radiotherapy outcome using dynamic contrast enhanced MRI of carcinoma of the cervix
Loncaster, J. A., Carrington, B. M., Sykes, J. R., Jones, A. P., Todd, S. M., Cooper, R., Buckley, D. L., Davidson, S. E., Logue, J. P., Hunter, R. D., et al. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02972-3 · Cited by 166
Port, R. E., Knopp, M. V., & Brix, G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1137 · Cited by 159
Self-citationDoleschel, D., Hoff, S., Koletnik, S., Rix, A., Zopf, D., Kiessling, F., & Lederle, W. (2021) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-021-02043-0 · Cited by 114
Benou, A., Veksler, R., Friedman, A., & Riklin Raviv, T. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.006 · Cited by 91
Metadata
- Authors
- Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1991-07
- Volume
- 15
- Issue
- 4
- Pages
- 621-628
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2036913456
- Cited by
- 659
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.