Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reliability of Differentiating Human Coronary Plaque Morphology Using Contrast-Enhanced Multislice Spiral Computed Tomography: A Comparison With Histology

Schroeder, Stephen, Kuettner, Axel, Leitritz, Martin, Janzen, Jan, Kopp, Andreas F, Herdeg, Christian, Heuschmid, Martin, Burgstahler, Christof, Baumbach, Andreas, Wehrmann, Manfred, Claussen, Claus D · 2004 · Journal of Computer Assisted Tomography

Abstract

BACKGROUND: Initial clinical results indicate that multislice spiral computed tomography (MDCT) might be useful for the noninvasive characterization of human coronary plaque morphology by determining tissue density within the lesions. This seems to be of clinical relevance, because coronary artery disease might be detected at an early stage before calcifications occur and noncalcified plaques that may be more likely to rupture could also be visualized noninvasively. The aim of the present study was to evaluate the reliability of contrast-enhanced MDCT in differentiating human atherosclerotic coronary plaque morphology by comparing it with the histopathologic gold standard. METHODS AND RESULTS: Twelve human hearts were scanned postmortem using an MDCT (Somatom Volume Zoom; Siemens, Forchheim, Germany) high-resolution computed tomography scanner to detect atherosclerotic coronary plaques. Density measurements were performed within detected plaque areas. The exact location of each plaque was marked at the surface of the heart to assure accurate histopathologic sectioning of these lesions. The plaques were classified according to a modified Stary classification. Seventeen plaques were identified by MDCT. Six plaques were histopathologically classified as lipid rich (Stary III/IV), 6 plaques as intermediate (Stary V), and 5 plaques as calcific (Stary VII). Lipid-rich plaques had a mean density on MDCT of 42 +/- 22 Hounsfield units (HU), intermediate plaques had a mean density of 70 +/- 21 HU, and calcific plaques had a mean density of 715 +/- 328 HU. ANOVA analysis revealed a significant difference in plaque density between the 3 groups (P < 0.0001). CONCLUSIONS: The comparison with histopathology confirms that tissue density as determined by contrast-enhanced MDCT might be used to differentiate atherosclerotic plaque morphology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-200407000-00003

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 183

Metadata

Authors
Schroeder, S., Kuettner, A., Leitritz, M., Janzen, J., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Baumbach, A., Wehrmann, M., & Claussen, C. D.
Venue
Journal of Computer Assisted Tomography
Published
2004
Volume
28
Issue
4
Pages
449-454
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2155996698
Cited by
183
References
1
FWCI
10.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Differentiating Human Coronary Plaque Morphology Using Contrast-Enhanced Multislice Spiral Computed Tomography: A Comparison With Histology. https://app.cochat.ai/papers/10.1097/00004728-200407000-00003
The paper
Schroeder, S., Kuettner, A., Leitritz, M., Janzen, J., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Baumbach, A., Wehrmann, M., & Claussen, C. D. (2004). Reliability of Differentiating Human Coronary Plaque Morphology Using Contrast-Enhanced Multislice Spiral Computed Tomography: A Comparison With Histology. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-200407000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.