Reliability of Differentiating Human Coronary Plaque Morphology Using Contrast-Enhanced Multislice Spiral Computed Tomography: A Comparison With Histology
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Initial clinical results indicate that multislice spiral computed tomography (MDCT) might be useful for the noninvasive characterization of human coronary plaque morphology by determining tissue density within the lesions. This seems to be of clinical relevance, because coronary artery disease might be detected at an early stage before calcifications occur and noncalcified plaques that may be more likely to rupture could also be visualized noninvasively. The aim of the present study was to evaluate the reliability of contrast-enhanced MDCT in differentiating human atherosclerotic coronary plaque morphology by comparing it with the histopathologic gold standard. METHODS AND RESULTS: Twelve human hearts were scanned postmortem using an MDCT (Somatom Volume Zoom; Siemens, Forchheim, Germany) high-resolution computed tomography scanner to detect atherosclerotic coronary plaques. Density measurements were performed within detected plaque areas. The exact location of each plaque was marked at the surface of the heart to assure accurate histopathologic sectioning of these lesions. The plaques were classified according to a modified Stary classification. Seventeen plaques were identified by MDCT. Six plaques were histopathologically classified as lipid rich (Stary III/IV), 6 plaques as intermediate (Stary V), and 5 plaques as calcific (Stary VII). Lipid-rich plaques had a mean density on MDCT of 42 +/- 22 Hounsfield units (HU), intermediate plaques had a mean density of 70 +/- 21 HU, and calcific plaques had a mean density of 715 +/- 328 HU. ANOVA analysis revealed a significant difference in plaque density between the 3 groups (P < 0.0001). CONCLUSIONS: The comparison with histopathology confirms that tissue density as determined by contrast-enhanced MDCT might be used to differentiate atherosclerotic plaque morphology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956 · cited 1×
“In addition, the new MDCT generation with 16 detector slices is already available with shorter examination times and stabilized image quality.(18) Further noninvasive imaging modalities such as magnetic resonance imaging and electron beam CT require no or less radiation.”
MethodCoronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Natural History and Histological Classification of Atherosclerotic Lesions: An Update
Stary, H. C. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.5.1177 · Cited by 752
Schroeder, S., Kopp, A. F., Baumbach, A., Meisner, C., Kuettner, A., Georg, C., Ohnesorge, B., Herdeg, C., Claussen, C. D., & Karsch, K. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01115-9 · Cited by 734 · cited 2×
“We recently demonstrated that plaque echogenicity as determined by ICUS corresponds well with plaque density on contrast-enhanced MDCT scans in an in vivo model.(6) The results of the present study comparing MDCT plaque density measurements with the histopathologic gold standard are in keeping with and confirm these i…”
ResultSelf-citationJakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615 · cited 1×
“Recent improvements of MDCT technology with reduced tube current during systole led to approximately a 40% to 50% reduction of the radiation exposure.(17) In addition, the new MDCT generation with 16 detector slices is already available with shorter examination times and stabilized image quality.”
BackgroundRadiation Dose in Computed Tomography of the Heart
Morin, R. L., Gerber, T. C., & McCollough, C. H. (2003) · Circulation · doi:10.1161/01.cir.0000048965.56529.c2 · Cited by 457
Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CT
Hunold, P., Vogt, F. M., Schmermund, A., Debatin, J. F., Kerkhoff, G., Budde, T., Erbel, R., Ewen, K., & Barkhausen, J. (2003) · Radiology · doi:10.1148/radiol.2261011365 · Cited by 405
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT
Becker, C. R., Nikolaou, K., Muders, M. H., Babaryka, G., Crispin, A., Schoepf, U. J., Loehrs, U., & Reiser, M. F. (2003) · European Radiology · doi:10.1007/s00330-003-1889-5 · Cited by 277
Fayad, Z. A., Fuster, V., Nikolaou, K., & Becker, C. (2002) · Circulation · doi:10.1161/01.cir.0000034392.34211.fc · Cited by 276
Cited by
Motoyama, S., Sarai, M., Harigaya, H., Anno, H., Inoue, K., Hara, T., Naruse, H., Ishii, J., Hishida, H., Wong, N. D., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.068 · Cited by 1,433
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citationHigh-Resolution CT Imaging of Carotid Artery Atherosclerotic Plaques
Wintermark, M., Jawadi, S. S., Rapp, J. H., Tihan, T., Tong, E., Glidden, D. V., Abedin, S., Schaeffer, S., Acevedo-Bolton, G., Boudignon, B., et al. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0950 · Cited by 370
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Pohle, K., Achenbach, S., MacNeill, B., Ropers, D., Ferencik, M., Moselewski, F., Hoffmann, U., Brady, T. J., Jang, I.-K., & Daniel, W. G. (2007) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2006.01.013 · Cited by 289
Association of High-Density Calcified 1K Plaque With Risk of Acute Coronary Syndrome
van Rosendael, A. R., Narula, J., Lin, F. Y., van den Hoogen, I. J., Gianni, U., Al Hussein Alawamlh, O., Dunham, P. C., Peña, J. M., Lee, S.-E., Andreini, D., et al. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.5315 · Cited by 175
Metadata
- Authors
- Schroeder, S., Kuettner, A., Leitritz, M., Janzen, J., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Baumbach, A., Wehrmann, M., & Claussen, C. D.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2004
- Volume
- 28
- Issue
- 4
- Pages
- 449-454
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2155996698
- Cited by
- 183
- References
- 15
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.