Blood Pressure Measurement in the Elderly: Correlation of Arterial Stiffness with Difference Between Intra-arterial and Cuff Pressures
The DOI matches its Crossref record.
Abstract
Intra-arterial (radial) blood pressure (BP) measurement was compared with the indirect cuff method in 55 healthy volunteers aged from 59-80 years (mean 68.6 +/- 5.2 s.d.). On average, the cuff method underestimated systolic BP by 5 mmHg and overestimated diastolic BP by 8 mmHg. Cuff measurement underestimated systolic BP by greater than 10 mmHg in 17 cases, and by greater than 20 mmHg in three cases. The cuff method overestimated diastolic BP by greater than 10 mmHg in nine cases (one greater than 20 mmHg) and in two cases the cuff overestimated diastolic BP by greater than 30 mmHg, compared with intra-arterial pressures. The differences correlated with pulse wave velocity, an index of arterial stiffness. A pulse wave velocity index reflecting the entire length from the aortic root to the posterior tibial artery (PWVI/ao-pt) gave a correlation (r) of 0.48 (P less than 0.0005) with systolic arterial/cuff (A/C) difference, a correlation of 0.43 (P less than 0.001) with diastolic A/C difference, and a correlation of 0.57 (P less than 0.00001) with the A/C difference in measurement of mean arterial pressure. A positive but weaker correlation was observed between A/C difference and PWVI aorta-femoral. Although the pressure differences were not as great in these healthy elderly subjects as in previous studies of patients suspected of having pseudo-hypertension, caution still appears to be indicated in the interpretation of cuff blood pressure measurement in the elderly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In particular, increased arterial stiffness leads to overestimation of systolic, diastolic and mean arterial BPs [60, 62–64].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [62]
Citations
Cites
Still being checked.
Cited by
Principles and Techniques of Blood Pressure Measurement
Ogedegbe, G., & Pickering, T. (2010) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 554
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179
Littenberg, B., Garber, A. M., & Sox, H. C. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-112-3-192 · Cited by 174
Omboni, S., Riva, I., Giglio, A., Caldara, G., Groppelli, A., & Parati, G. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32813fa386 · Cited by 129
Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures
CLOUD, G. C., Rajkumar, C., Kooner, J. S., COOKE, J., & Bulpitt, C. J. (2003) · Clinical Science · doi:10.1042/cs20030012 · Cited by 120
Metadata
- Authors
- Finnegan, T. P., Spence, J. D., Wong, D. G., & Wells, G. A.
- Affiliations
- Western University (CA)
- Corresponding author
- Finnegan, Terrence P.
- Venue
- Journal of Hypertension
- Published
- 1985-06
- Volume
- 3
- Issue
- 3
- Pages
- 231-235
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2054580932
- Cited by
- 56
- References
- 0
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 7 · 2019: 2 · 2018: 3 · 2015: 2
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Keywords
- intra-arterial blood pressure, radial artery pressure, arterial stiffness, pulse wave velocity, older adults, measurement error, systolic blood pressure, diastolic blood pressure, mean arterial pressure
- MeSH terms
- Aged, Aging, Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood Pressure Measurement in the Elderly: Correlation of Arterial Stiffness with Difference Between Intra-arterial and Cuff Pressures. https://app.cochat.ai/papers/10.1097/00004872-198506000-00006
- The paper
- Finnegan, T. P., Spence, J. D., Wong, D. G., & Wells, G. A. (1985). Blood Pressure Measurement in the Elderly: Correlation of Arterial Stiffness with Difference Between Intra-arterial and Cuff Pressures. Journal of Hypertension. https://doi.org/10.1097/00004872-198506000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.