An evaluation of the A& D UA-751 semi-automated cuff-oscillometric sphygmomanometer
The DOI matches its Crossref record.
Abstract
We compared blood pressure recordings made with the A&D UA-751 semi-automated cuff-oscillometric sphygmomanometer (A&D Co. Ltd, Tokyo, Japan) and with a conventional Hawksley random-zero mercury sphygmomanometer (Hawksley and Sons Ltd, Lancing, UK). Simultaneous single-arm recordings were obtained in duplicate with both devices in 200 subjects having blood pressure in the ranges 92-221/51-121 mmHg. The measurements obtained by three observers using the Hawksley sphygmomanometer were compared with recordings from two A&D UA-751 devices. In most cases, there was an acceptable level of agreement between the results, according to the criteria suggested by the Association for the Advancement of Medical Instrumentation (range of differences systolic: mean - 0.9 to 1.4 mmHg, s.d. 4.6-9.8 mmHg; diastolic: mean - 0.6 to 1.3 mmHg, s.d. 2.9-5.1 mmHg), although there were sizeable discrepancies in individual subjects. Thus the A&D UA-751 device appears to be an acceptable alternative to a conventional sphygmomanometer; it should be suitable for routine clinical and limited research use, including intermittent home blood pressure recording.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood Pressure Outcome of Angioplasty in Atherosclerotic Renal Artery Stenosis: A Randomized Trial
Plouin, P.-F., Chatellier, G., Darné, B., & Raynaud, A. (1998) · Hypertension · doi:10.1161/01.hyp.31.3.823 · Cited by 585
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D. (2002) · BMJ · doi:10.1136/bmj.325.7358.254 · Cited by 171
Evaluation of a modified cognitive-behavioural programme for weight management
Rapoport, L., Clark, M., & Wardle, J. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801465 · Cited by 141
Home Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Metadata
- Authors
- Jamieson, M. J., Webster, J., Witte, K., Huggins, M. M., MacDonald, T. M., de Beaux, A., & Petrie, J. C.
- Venue
- Journal of Hypertension
- Published
- 1990-04
- Volume
- 8
- Issue
- 4
- Pages
- 377-381
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2026674070
- Cited by
- 34
- References
- 0
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An evaluation of the A& D UA-751 semi-automated cuff-oscillometric sphygmomanometer. https://app.cochat.ai/papers/10.1097/00004872-199004000-00012
- The paper
- Jamieson, M. J., Webster, J., Witte, K., Huggins, M. M., MacDonald, T. M., de Beaux, A., & Petrie, J. C. (1990). An evaluation of the A& D UA-751 semi-automated cuff-oscillometric sphygmomanometer. Journal of Hypertension. https://doi.org/10.1097/00004872-199004000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.