CoChat

Ambulatory blood pressure in normotensive and hypertensive subjects: results from an international database

Staessen, Jan A., O??Brien, Eoin T., Amery, Antoon K., Atkins, Neil, Baumgart, Peter, Cort, Paul De, Degaute, Jean-Paul, Dolenc, Primoz, Gaudemaris, Regis De, Enstr??m, Inger, Fagard, Robert, Gosse, Philippe, Gourlay, Steve, Hayashi, Hiroshi, Imai, Yutaka, James, Gary, Kawasaki, Terukazu, Kuschnir, Emilio, Kuwajima, Iwao, Lindholm, Lars, Liu, Lisheng, Macor, Franco, Mancia, Giuseppe, McGrath, Barry, Middeke, Martin, Ming, Jian, Omboni, Stefano, Otsuka, Kuniaka, Palatini, Paolo, Parati, Gianfranco, Pieper, Carl, Verdecchia, Paolo, Zachariah, Prince, Zhang, Weizhong · 1994 · Journal of Hypertension
Cited by 132

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To delineate more precisely an operational threshold for making clinical decisions based on ambulatory blood pressure (ABP) measurement by studying the ABP in subjects who were diagnosed as either normotensive or hypertensive by conventional blood pressure (CBP) measurement. SUBJECTS: Twenty-four research groups recruited 7069 subjects. Of these, 4577 were normotensive (CBP < or = 140/90 mmHg), 719 were borderline hypertensive (systolic CBP 141-159 mmHg or diastolic CBP 91-94 mmHg) and 1773 were definitely hypertensive. Of the subjects in the last of these categories, 1324 had systolic hypertension (systolic CBP > or = 160 mmHg) and 1310 had diastolic hypertension (diastolic CBP > or = 95 mmHg). Combined systolic and diastolic hypertension was present in 861 subjects. Hypertension had been diagnosed from the mean of two to nine (median two) CBP measurements obtained at one to three (median two) visits. RESULTS: The 95th centiles of the ABP distributions in the normotensive subjects were (systolic and diastolic, respectively) 133 and 82 mmHg for 24-h ABP, 140 and 88 mmHg for daytime ABP and 125 and 76 mmHg for night-time ABP, respectively. Of the subjects with systolic hypertension, 24% had 24-h systolic ABP < 133 mmHg. Similarly, 30% of those with diastolic hypertension had 24-h diastolic ABP < 82 mmHg. The probability that hypertensive subjects had 24-h ABP below these thresholds tended to increase with age and was two- to fourfold greater if the CBP of the subject had been measured at only one visit and if fewer than three CBP measurements had been averaged for establishing the diagnosis of hypertension. By contrast, for each 10-mmHg increment in systolic CBP, this probability decreased by 54% for 24-h systolic ABP and by 26% for 24-h diastolic ABP, and for each 5-mmHg increment in diastolic CBP it decreased by 6 and 9%, respectively. In comparison with 24-h ABP, the overlap in the daytime and night-time ABP between normotensive and hypertensive subjects was of similar magnitude and was influenced by the same factors. CONCLUSIONS: The ABP distributions of the normotensive subjects included in the present international database were not materially different from those in previous reports in the literature. One-fifth to more than one-third of hypertensive subjects had an ABP which was below the 95th centile of the ABP of normotensive subjects, but this proportion decreased if the hypertensive subjects had shown a higher CBP upon repeated measurement. The prognostic implications of elevated CBP in the presence of normal ABP remain to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-199400127-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 132

Metadata

Authors
Staessen, J. A., O??Brien, E. T., Amery, A. K., Atkins, N., Baumgart, P., Cort, P. D., Degaute, J.-P., Dolenc, P., Gaudemaris, R. D., Enstr??m, I., Fagard, R., Gosse, P., Gourlay, S., Hayashi, H., Imai, Y., James, G., Kawasaki, T., Kuschnir, E., Kuwajima, I., Lindholm, L., Liu, L., Macor, F., Mancia, G., McGrath, B., Middeke, M., Ming, J., Omboni, S., Otsuka, K., Palatini, P., Parati, G., Pieper, C., Verdecchia, P., Zachariah, P., & Zhang, W.
Venue
Journal of Hypertension
Published
1994
Volume
12
Issue
Supplement 7
Pages
S13???S22
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2070434008
Cited by
132
References
0
Type
conference abstract
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ambulatory blood pressure in normotensive and hypertensive subjects: results from an international database. https://app.cochat.ai/papers/10.1097/00004872-199400127-00001
The paper
Staessen, J. A., O??Brien, E. T., Amery, A. K., Atkins, N., Baumgart, P., Cort, P. D., Degaute, J.-P., Dolenc, P., Gaudemaris, R. D., Enstr??m, I., Fagard, R., Gosse, P., Gourlay, S., Hayashi, H., Imai, Y., James, G., Kawasaki, T., Kuschnir, E., Kuwajima, I., . . . Zhang, W. (1994). Ambulatory blood pressure in normotensive and hypertensive subjects: results from an international database. Journal of Hypertension. https://doi.org/10.1097/00004872-199400127-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.