Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to determine the reproducibility of pulse wave velocity (PWV) and augmentation index (AIx) measured using pulse wave analysis (PWA), prior to its use in large-scale clinical trials. METHODS: Arterial pressure waveforms were recorded and analysed using an established technique (Sphygmocor). Subjects with and without a range of recognized cardiovascular risk factors were studied to provide a wide range of values. Measurements were made after a brief introduction to the technique in a clinical setting. Two observers recorded aortic and brachial PWV in 24 subjects, each on two occasions, in a random order. In a separate study, two different observers used PWA to determine AIx in 33 subjects, each on two occasions, in a random order. Data were analysed using Bland-Altman plots and presented as mean +/- SD. RESULTS: Brachial PWV was 8.65+/-1.58 m/s (range 6.16-10.95 m/s) and aortic PWV was 8.15+/-3.01 m/s (5.01-17.97 m/s). Within-observer variability was 0.14+/-0.82 m/s for brachial PWV and 0.07+/-1.17 m/s for aortic PWV. Corresponding between-observer values were -0.44+/-1.09 m/s and -0.30+/-1.25 m/s. AIx ranged from -15.0 to +45.0%, with a group mean of +19.6+/-12.0%. The within-observer difference was 0.49+/-5.37% and between-observer difference 0.23+/-3.80%. CONCLUSION: PWA is a simple and reproducible technique with which to measure PWV and AIx. Reproducibility accords with that reported by other workers using different methodologies. PWA may, therefore, be suitable for large-scale population and intervention studies investigating the clinical relevance of vascular stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Asmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Arterial Stiffness: A New Cardiovascular Risk Factor?
Arnett, D. K., Evans, G. W., & Riley, W. A. (1994) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117315 · Cited by 483
Does Radial Artery Pressure Accurately Reflect Aortic Pressure?
Pauca, A. L., Wallenhaupt, S. L., Kon, N. D., & Tucker, W. Y. (1992) · Chest · doi:10.1378/chest.102.4.1193 · Cited by 341
Vascular Compliance and Cardiovascular Disease A Risk Factor or a Marker?
Glasser, S. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00311-7 · Cited by 308
Wave reflection in the systemic circulation and its implications in ventricular function
O??Rourke, M. F., & Kelly, R. P. (1993) · Journal of Hypertension · doi:10.1097/00004872-199304000-00001 · Cited by 278
Lee, A. J., Mowbray, P. I., Lowe, G. D. O., Rumley, A., Fowkes, F. G. R., & Allan, P. L. (1998) · Circulation · doi:10.1161/01.cir.97.15.1467 · Cited by 230
Hjemdahl, P., & Friberg, P. (1996) · Journal of Hypertension · doi:10.1097/00004872-199602000-00001 · Cited by 196
Non-invasive assessment of cardiovascular disease in diabetes mellitus
Lehmann, E. D., Riley, W. A., Clarkson, P., & Gosling, R. G. (1997) · The Lancet · doi:10.1016/s0140-6736(97)90023-4 · Cited by 156
Aortic compliance measurements using doppler ultrasound: In vivo biochemical correlates
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90087-5 · Cited by 129
McVeigh, G. E., Brennan, G., Hayes, R., Cohn, J. N., Finkelstein, S. M., & Johnston, D. (1993) · The American Journal of Medicine · doi:10.1016/0002-9343(93)90313-e · Cited by 123
Hodes, R. J., Lakatta, E. G., & McNeil, C. (1995) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1995.tb06111.x · Cited by 110
The Trevor Howell Lecture Age, Arterial Stiffness and the Endothelium
Cockcrofx, J. R., Wilkinson, I. B., & Webb, D. J. (1997) · Age and Ageing · doi:10.1093/ageing/26.suppl_4.53 · Cited by 61
Self-citationCognitive therapy with elderly people
Wilkinson, P. (1997) · Age and Ageing · doi:10.1093/ageing/26.1.53 · Cited by 45
Goonasekera, C. D. A., & Dillon, M. J. (1995) · PubMed · Cited by 28
Cited by
Sutton, E. F., Beyl, R., Early, K. S., Cefalu, W. T., Ravussin, E., & Peterson, C. M. (2018) · Cell Metabolism · doi:10.1016/j.cmet.2018.04.010 · Cited by 1,531
Cruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531
Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave Velocity
McEniery, C. M., Yasmin, Hall, I. R., Qasem, A., Wilkinson, I. B., & Cockcroft, J. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.037 · Cited by 1,359
Self-citationThe influence of heart rate on augmentation index and central arterial pressure in humans
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00263.x · Cited by 1,091
Self-citationNoninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Self-citation
Metadata
- Authors
- Wilkinson, I. B., Fuchs, S. A., Jansen, I. M., Spratt, J. C., Murray, G. D., Cockcroft, J. R., & Webb, D. J.
- Venue
- Journal of Hypertension
- Published
- 1998-12
- Volume
- 16
- Issue
- Supplement
- Pages
- 2079-2084
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2070073147
- Cited by
- 924
- References
- 16
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.