Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,091

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The influence of heart rate on augmentation index and central arterial pressure in humans

Open access
Wilkinson, Ian B., MacCallum, Helen, Flint, Laura, Cockcroft, John R., Newby, David E., Webb, David J.·2000·The Journal of Physiology

Abstract

Arterial stiffness is an important determinant of cardiovascular risk. Augmentation index (AIx) is a measure of systemic arterial stiffness derived from the ascending aortic pressure waveform. The aim of the present study was to assess the effect of heart rate on AIx. We elected to use cardiac pacing rather than chronotropic drugs to minimize confounding effects on the systemic circulation and myocardial contractility. Twenty-two subjects (13 male) with a mean age of 63 years and permanent cardiac pacemakers in situ were studied. Pulse wave analysis was used to determine central arterial pressure waveforms, non-invasively, during incremental pacing (from 60 to 110 beats min-1), from which AIx and central blood pressure were calculated. Peripheral blood pressure was recorded non-invasively from the brachial artery. There was a significant, inverse, linear relationship between AIx and heart rate (r = -0.76; P < 0.001). For a 10 beats min-1 increment, AIx fell by around 4 %. Ejection duration and heart rate were also inversely related (r = -0. 51; P < 0.001). Peripheral systolic, diastolic and mean arterial pressure increased significantly during incremental pacing. Although central diastolic pressure increased significantly with pacing, central systolic pressure did not. There was a significant increase in the ratio of peripheral to central pulse pressure (P < 0.001), which was accounted for by the observed change in central pressure augmentation. These results demonstrate an inverse, linear relationship between AIx and heart rate. This is likely to be due to alterations in the timing of the reflected pressure wave, produced by changes in the absolute duration of systole. Consideration of wave reflection and aortic pressure augmentation may explain the lack of rise in central systolic pressure during incremental pacing despite an increase in peripheral pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.2000.t01-1-00263.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 37

  1. 10.1016/S0002-9149(73)80130-4 · doi:10.1016/s0002-9149(73)80130-4
  2. 10.1161/01.CIR.43.3.407 · DOI
  3. 10.1161/01.HYP.30.6.1410 · DOI · Paper page
  4. 10.1113/jphysiol.1961.sp006687 · DOI · Paper page
  5. 10.1016/B978-0-12-089901-2.50011-9 · doi:10.1016/b978-0-12-089901-2.50011-9
  6. 10.1136/hrt.35.10.1033 · doi:10.1136/hrt.35.10.1033
  7. Clement D., 1979, Left ventricular systolic time intervals and cardiac haemodynamics during atrial pacing in normal subjects and patients with coronary artery disease, Acta Cardiologica, 34, 233
  8. 10.1109/10.764946 · DOI · Paper page
  9. 10.1161/01.CIR.100.4.354 · DOI · Paper page
  10. 10.1161/01.CIR.80.6.1652 · DOI · Paper page
  11. Kelly R. P., 1989, Non‐invasive registration of the arterial pulse waveform using high fidelity applanation tonometry, Journal of Vascular and Medical Biology, 1, 142
  12. 10.1161/01.CIR.47.4.690 · doi:10.1161/01.cir.47.4.690
  13. 10.1093/eurheartj/11.suppl_G.29 · DOI
  14. 10.1161/01.CIR.72.6.1257 · DOI · Paper page
  15. 10.1016/0021-9681(56)90158-8 · DOI
  16. Mahomed F. A., 1872, The physiological and clinical use of the sphygmograph, Medical Times Gazette, 1, 62
  17. 10.1161/01.HYP.22.6.876 · DOI · Paper page
  18. 10.1161/01.CIR.62.1.105 · DOI · Paper page
  19. 10.1161/01.RES.40.5.451 · doi:10.1161/01.res.40.5.451
  20. Nichols W. W., 1998, McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
  21. 10.1093/cvr/1.1.9 · doi:10.1093/cvr/1.1.9
  22. O'Brien E., 1996, Evaluation of three devices for self measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM‐705CP, Philips HP5332, and Nissei DS‐175, Blood Pressure Monitoring, 1, 55
  23. 10.1161/01.HYP.15.4.339 · DOI · Paper page
  24. O'Rourke M. F., 1996, Pulse wave analysis, Journal of Hypertension, 14, 147
  25. 10.1161/01.RES.20.4.365 · DOI · Paper page
  26. 10.1161/01.CIR.43.2.241 · doi:10.1161/01.cir.43.2.241
  27. 10.1378/chest.102.4.1193 · DOI · Paper page
  28. 10.1016/0735-1097(93)90772-S · DOI · Paper page
  29. 10.1097/00004872-199715120-00009 · DOI · Paper page
  30. Soderstrom S., 1998, Substantial equivalence between ascending aortic pressure waveforms and waveforms derived from the radial pulse using a generalized transfer function?, FASEB Journal, 712, 4131
  31. 10.1136/hrt.26.6.737 · doi:10.1136/hrt.26.6.737
  32. 10.1016/S0008-6363(98)00115-1 · DOI
  33. Takazawa K., 1996, Estimation of ascending aortic pressure from radial arterial pressure using a generalized transfer function, Zeitschrift fur Kardiologie, 85, 137
  34. 10.1016/S0735-1097(96)00389-0 · DOI
  35. 10.1097/00004872-199509000-00002 · DOI · Paper page
  36. Wilkinson I. B., 1999, Pulse wave analysis and arterial stiffness, Journal of Cardiovascular Pharmacology, 32, 33
  37. 10.1097/00004872-199816121-00033 · DOI · Paper page

Cited by

See all 1,091

Metadata

Authors
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2000-05
Volume
525
Issue
1
Pages
263-270
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2016913364
Cited by
1,091
References
5
FWCI
13.87
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The influence of heart rate on augmentation index and central arterial pressure in humans. https://app.cochat.ai/papers/10.1111/j.1469-7793.2000.t01-1-00263.x
The paper
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000). The influence of heart rate on augmentation index and central arterial pressure in humans. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.2000.t01-1-00263.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.