Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 382

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking

Open access
Van Bortel, Luc M., Balkestein, Elisabeth J., van der Heijden-Spek, Janneke J., Vanmolkot, Floris H., Staessen, Jan A., Kragten, Johannes A., Vredeveld, Jan W., Safar, Michel E., Boudier, Harry A. Struijker, Hoeks, Arnold P.·2001·Journal of Hypertension

Abstract

OBJECTIVES: Pulse pressure is not constant throughout the arterial tree. Use of pulse pressure at one arterial site as surrogate for pulse pressure at another arterial site may be erroneous. The present study compares three non-invasive techniques to measure local pulse pressure: (i) internally calibrated readings from applanation tonometry, (ii) alternative calibration of pressure waves obtained with applanation tonometry and (iii) alternative calibration of arterial distension waves obtained with echo-tracking. Alternative calibration assumes mean and diastolic blood pressure constant throughout the large artery tree. DESIGN AND METHODS: Study 1 used invasive measurements in the ascending aorta as a reference method and internally calibrated tonometer readings and alternatively calibrated pressure waves at the common carotid artery as test methods. Study 2 used alternatively calibrated pressure waves as a reference method and alternatively calibrated distension waves and internally calibrated applanation tonometer readings as test methods. RESULTS: In study 1, pulse pressure from internally calibrated tonometer readings was 10.2+/-14.3 mmHg lower and pulse pressure from alternatively calibrated pressure waves was 1.8+/-5.2 mmHg higher than invasive pulse pressure. Pulse pressure from calibrated distension waves was 3.4+/-6.9 mmHg lower than pulse pressure from alternatively calibrated pressure waves. According to British Hypertension Society criteria, pulse pressure from the internally calibrated tonometer achieved grade D and pulse pressure from alternatively calibrated pressure waves achieved grade A. Pulse pressure from calibrated distension waves achieved grade B when alternatively calibrated pressure waves were used as a reference method. CONCLUSIONS: Pulse pressure obtained from alternatively calibrated tonometer-derived pressure waves and echo-tracking-derived distension waves demonstrates good accuracy. Accuracy of pulse pressure from internally calibrated applanation tonometer readings at the carotid artery is poor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200106000-00007

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 382

Metadata

Authors
Van Bortel, L. M., Balkestein, E. J., van der Heijden-Spek, J. J., Vanmolkot, F. H., Staessen, J. A., Kragten, J. A., Vredeveld, J. W., Safar, M. E., Boudier, H. A. S., & Hoeks, A. P.
Venue
Journal of Hypertension
Published
2001-06
Volume
19
Issue
6
Pages
1037-1044
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2163580434
Cited by
382
References
24
FWCI
7.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking. https://app.cochat.ai/papers/10.1097/00004872-200106000-00007
The paper
Van Bortel, L. M., Balkestein, E. J., van der Heijden-Spek, J. J., Vanmolkot, F. H., Staessen, J. A., Kragten, J. A., Vredeveld, J. W., Safar, M. E., Boudier, H. A. S., & Hoeks, A. P. (2001). Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking. Journal of Hypertension. https://doi.org/10.1097/00004872-200106000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.