CoChat

Gender differences in the timing of arterial wave reflection beyond differences in body height

Gatzka, Christoph D., Kingwell, Bronwyn A., Cameron, James D., Berry, Karen L., Liang, Yu-Lu, Dewar, Elizabeth M., Reid, Chris M., Jennings, Garry L., Dart, Anthony M. · 2001 · Journal of Hypertension
Cited by 173

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: The timing of arterial wave reflection affects the shape of the arterial waveform and thus is a major determinant of pulse pressure. This study assessed differences in wave reflection between genders beyond the effect of body height. METHODS: From 1123 elderly (aged 71 +/- 5 years) currently untreated hypertensives, we selected 104 pairs of men and women with identical body height (average 164 +/- 4 cm). All subjects underwent echocardiography, including measurement of aortic arch expansion, automated blood pressure measurements, measurement of ascending aortic blood flow and simultaneous carotid artery tonometry. RESULTS: Women had higher pulse (80 +/- 17 versus 74 +/- 17 mmHg, P < 0.05) and lower diastolic pressure (79 +/- 11 versus 82 +/- 10 mmHg, P < 0.05). Whilst heart rate was similar, women had a longer time to the systolic peak (210 +/- 28 versus 199 +/- 34 ms, P < 0.01) and a longer ejection time (304 +/- 21 versus 299 +/- 25 ms, P < 0.001). Wave reflection occurred earlier in women (time between maxima 116 +/- 55 versus 132 +/- 47 ms, P < 0.05) and augmentation index was higher (36 +/- 11 versus 28 +/- 12%, P < 0.001). Aortic diameter was smaller in women and the aortic arch was stiffer (median Ep 386 versus 302 kN/m2, P < 0.05). Hence, systemic arterial compliance was less in women (0.8 +/- 0.2 versus 1.0 +/- 0.3 ml/mmHg). CONCLUSIONS: We conclude that elderly hypertensive men and women have a different timing of both left ventricular ejection and arterial wave reflection when both genders are matched for body height. Women have smaller and stiffer blood vessels resulting in an earlier return of the reflected wave, which is likely due to an increased pulse wave velocity in women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200112000-00013

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Gatzka, C. D., Kingwell, B. A., Cameron, J. D., Berry, K. L., Liang, Y.-L., Dewar, E. M., Reid, C. M., Jennings, G. L., & Dart, A. M.
Venue
Journal of Hypertension
Published
2001-12
Volume
19
Issue
12
Pages
2197-2203
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2316239431
Cited by
173
References
31
FWCI
4.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.