Inter-arm differences in blood pressure: when are they clinically significant?
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine whether there is significant disparity in blood pressure between the two arms. DESIGN: Prospective, observational study. SETTING: One general hospital in Birmingham, England. PARTICIPANTS: Four hundred participants [age 56.3 +/- 19.7 years (mean +/- SD), 50% male] were recruited from staff and patients. Simultaneous bilateral blood pressure measurements were obtained using Omron HEM-705CP automated oscillatory devices; with two measurements taken in each arm. MAIN OUTCOME MEASURES: Mean inter-arm blood pressure differences and frequency of clinically important disparities. RESULTS: Mean +/- SD inter-arm differences in systolic and diastolic blood pressure were 1.81 +/- 8.6 mmHg and -0.23 +/- 8.3 mmHg, respectively. The analogous figures for mean +/- SD absolute differences were 6.32 +/- 6.12 mmHg and 5.06 +/- 6.57 mmHg, respectively. Significant differences were present between the mean right and left arm systolic blood pressure [t(399) = 4.20, P < 0.0001], and the mean absolute difference for both systolic [t(399) = 20.65; P < 0.0001] and diastolic [t(399) = 15.39; P < 0.0001] blood pressure. The variation in mean inter-arm blood pressure was unrelated to age, sex, ethnicity, arm circumference, handedness, being hypertensive, diabetic, or previous history of cardiovascular disease. Clinically significant inter-arm differences in systolic blood pressure of > 10 and > 20 mmHg were found in 20 and 3.5%, respectively; diastolic differences of > 10 and > 20 mmHg were present in 11 and 3.5%, respectively. Age was the only significant predictor of clinically significant variations in inter-arm blood pressures and mean absolute blood pressure differences. CONCLUSIONS: Significant differences in mean inter-arm systolic blood pressure, and mean absolute inter-arm systolic and diastolic blood pressure are present. This emphasizes the importance of measuring blood pressure in both arms initially to prevent this misdiagnosis of hypertension, due to normal differences in blood pressure between the arms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
(1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440420033005 · Cited by 3,777
(1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,695
Human blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Blood Pressure, Systolic and Diastolic, and Cardiovascular Risks: US Population Data
Stamler, J. (1993) · Archives of Internal Medicine · doi:10.1001/archinte.1993.00410050036006 · Cited by 1,015
Ramsay, L., Williams, B., Johnston, G., MacGregor, G., Poston, L., Potter, J., Poulter, N., Russell, G., & for the British Hypertension Society (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000917 · Cited by 585
Recommendations on blood pressure measurement.
Petrie, J. C., O'Brien, E. T., Littler, W. A., & de Swiet, M. (1986) · BMJ · doi:10.1136/bmj.293.6547.611 · Cited by 396
(1993) · Archives of Internal Medicine · doi:10.1001/archinte.153.2.154 · Cited by 396
Arterial baroreflexes and blood pressure and heart rate variabilities in humans.
Mancia, G., Parati, G., Pomidossi, G., Casadei, R., Di Rienzo, M., & Zanchetti, A. (1986) · Hypertension · doi:10.1161/01.hyp.8.2.147 · Cited by 267
Does This Patient Have Hypertension? How to Measure Blood Pressure
Reeves, R. A. (1995) · JAMA · doi:10.1001/jama.273.15.1211 · Cited by 202
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Blood pressure variability and cardiovascular disease: systematic review and meta-analysis
Stevens, S. L., Wood, S., Koshiaris, C., Law, K., Glasziou, P., Stevens, R. J., & McManus, R. J. (2016) · BMJ · doi:10.1136/bmj.i4098 · Cited by 871
“14 18 19 Measurement at different times of the day 20 or year, 21 in different arms, 22 or using inconsistent cuff sizes 23 can affect accurate measurement, thereby inducing variability.”
Clark, C. E., Taylor, R. S., Shore, A. C., Ukoumunne, O. C., & Campbell, J. L. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61710-8 · Cited by 422
Subclavian Artery Stenosis: Prevalence, Risk Factors, and Association With Cardiovascular Diseases
Shadman, R., Criqui, M. H., Bundens, W. P., Fronek, A., Denenberg, J. O., Gamst, A. C., & McDermott, M. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.04.044 · Cited by 380
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Protocol for Measurement of Mean Arterial Pressure at 11-13 Weeks' Gestation
Poon, L. C. Y., Zymeri, N. A., Zamprakou, A., Syngelaki, A., & Nicolaides, K. H. (2012) · Fetal Diagnosis and Therapy · doi:10.1159/000335366 · Cited by 260
Management of Glomerular Proteinuria: A Commentary
Wilmer, W. A., Rovin, B. H., Hebert, C. J., Rao, S. V., Kumor, K., & Hebert, L. A. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000100145.27188.33 · Cited by 217
“The arm with the higher BP is used for future BP measurement (42).”
MethodBlood Pressure Measurement Guidelines for Physical Therapists
Frese, E. M., Fick, A., & Sadowsky, S. H. (2011) · Cardiopulmonary Physical Therapy Journal · doi:10.1097/01823246-201122020-00002 · Cited by 198
GALLAGHER, D., ADJI, A., & OROURKE, M. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.05.027 · Cited by 194
“Such errors affect all interpretations that follow from use of the conventional cuff sphygmomanometer.(1,57) In conclusion, determination of central pressure is a new concept, and while theoretically attractive, has little Table 4.”
BackgroundThe difference in blood pressure readings between arms and survival: primary care cohort study
Clark, C. E., Taylor, R. S., Shore, A. C., & Campbell, J. L. (2012) · BMJ · doi:10.1136/bmj.e1327 · Cited by 158
Severin, R., Sabbahi, A., Albarrati, A., Phillips, S. A., & Arena, S. (2020) · Physical Therapy · doi:10.1093/ptj/pzaa034 · Cited by 43
Metadata
- Authors
- Lane, D., Beevers, M., Barnes, N., Bourne, J., John, A., Malins, S., & Beevers, D. G.
- Venue
- Journal of Hypertension
- Published
- 2002-06
- Volume
- 20
- Issue
- 6
- Pages
- 1089-1095
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2043090180
- Cited by
- 178
- References
- 19
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.