The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Distribution of 24-h ambulatory blood pressure in children: normalized reference values and role of body dimensions
Abstract
BACKGROUND: Twenty-four-hour ambulatory blood pressure monitoring (ABPM) is an essential tool in the diagnosis and therapeutic monitoring of arterial hypertension in children. The statistical use of pediatric ABPM reference values has been compromised by the non-Gaussian distribution of 24-h blood pressure (BP) in children. OBJECTIVE: To develop distribution-adjusted pediatric ABPM reference tables. METHODS: From cross-sectional ABPM data obtained in 949 healthy children and adolescents aged 5-20 years, a set of reference tables was developed for 24-h, daytime and night-time mean values of systolic, diastolic, mean arterial BP and heart rate, utilizing the LMS method to account for the variably skewed distribution of ABPM data. Age- and gender-specific estimates of the distribution median (M), coefficient of variation (S) and degree of skewness (L) were obtained by a maximum-likelihood curve-fitting technique. The estimates of, and can be used to normalize ABPM data to gender and age or height. RESULTS: Re-application of the established, and values in the reference population confirmed appropriate normalization of ABPM values. Height standard deviation scores (SDS), body mass index (BMI) SDS and heart rate SDS were independent positive predictors of 24-h systolic BP SDS. Diastolic 24-h mean BP SDS showed a weak correlation with BMI SDS only. CONCLUSIONS: The use of LMS reference tables permits calculation of appropriate SDS values for ABPM in children. Whereas systolic 24-h BP is independently correlated with age, relative height and obesity, diastolic values are almost independent of age and relative height, and weakly associated with relative obesity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Journal of Hypertension · doi:10.1097/00004872-199917020-00001 · Cited by 3,695
Smoothing reference centile curves: The lms method and penalized likelihood
Cole, T. J., & Green, P. J. (1992) · Statistics in Medicine · doi:10.1002/sim.4780111005 · Cited by 2,781
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Blood Pressure, Systolic and Diastolic, and Cardiovascular Risks: US Population Data
Stamler, J. (1993) · Archives of Internal Medicine · doi:10.1001/archinte.1993.00410050036006 · Cited by 1,015
National High Blood Pressure Education Program Working Group on Hypertension Control in Children and Adolescents (1996) · Pediatrics · doi:10.1542/peds.98.4.649 · Cited by 999
The Prognostic Value of Ambulatory Blood Pressures
Perloff, D. (1983) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1983.03330440030027 · Cited by 880
Soergel, M., Kirschstein, M., Busch, C., Danne, T., Gellermann, J., Holl, R., Krull, F., Reichert, H., Reusz, G. S., & Rascher, W. (1997) · The Journal of Pediatrics · doi:10.1016/s0022-3476(97)70340-8 · Cited by 625
Self-citationAlerting reaction and rise in blood pressure during measurement by physician and nurse.
Mancia, G., Parati, G., Pomidossi, G., Grassi, G., Casadei, R., & Zanchetti, A. (1987) · Hypertension · doi:10.1161/01.hyp.9.2.209 · Cited by 483
Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society Protocol
O??Brien, E., Mee, F., Atkins, N., & O??Malley, K. (1991) · Journal of Hypertension · doi:10.1097/00004872-199106000-00016 · Cited by 451
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Cheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Lurbe, E., Agabiti-Rosei, E., Cruickshank, J. K., Dominiczak, A., Erdine, S., Hirth, A., Invitti, C., Litwin, M., Mancia, G., Pall, D., et al. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000001039 · Cited by 1,379
Self-citation
Metadata
- Authors
- Wühl, E., Witte, K., Soergel, M., Mehls, O., & Schaefer, F.
- Venue
- Journal of Hypertension
- Published
- 2002-10
- Volume
- 20
- Issue
- 10
- Pages
- 1995-2007
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2034647476
- Cited by
- 816
- References
- 30
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Distribution of 24-h ambulatory blood pressure in children: normalized reference values and role of body dimensions. https://app.cochat.ai/papers/10.1097/00004872-200210000-00019
- The paper
- Wühl, E., Witte, K., Soergel, M., Mehls, O., & Schaefer, F. (2002). Distribution of 24-h ambulatory blood pressure in children: normalized reference values and role of body dimensions. Journal of Hypertension. https://doi.org/10.1097/00004872-200210000-00019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.