New Instrument That Uses Near-Infrared Spectroscopy for the Monitoring of Human Muscle Oxygenation
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background Early detection of vascular impairments after free tissue transfers are essential to prevent flap failure. Near-infrared spectroscopy showed good promise to monitor flaps at deep levels successfully without being invasive. The purpose of this study was to test whether the INVOS 3100 cerebral oxymeter is capable of detecting circulatory impairments. Methods In 10 healthy adults, near-infrared spectroscopy was used to measure regional saturation values during tourniquet ischemia and venous outflow restriction, in two test cycles. The probe, containing an infrared-light-emitting source and two infrared-light sensors, was placed below the elbow above the brachioradialis muscle. Statistical comparison of the data was performed using the Friedman test and the Wilcoxon-Wilcox test. Results Venous and arterial occlusions were characterized by an instantaneous fall of the regional saturation. Arterial occlusion showed a mean decrease of the saturation values down to 28+/-9%, whereas venous occlusion showed a mean fall of saturation values down to 51+/-12%. These falls were significant after 3 minutes of occlusion compared with baseline values (74+/-6%). The differences between arterial and venous occlusions were statistically significant. Conclusion This study, designed to test less-expensive equipment, was able to measure absolute values, and was not prone to interference caused by probe movement, providing information on the oxygenation profile accurately and noninvasivel…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Alternative spatial resolution (SR) methods use a larger separation among measurement sites; light transport models assuming the shorter distance predominantly measures surface tissues and the longer distance deeper tissues are used to calculate a tissue oxygen saturation for the deeper (muscle/brain) region of interest. 21”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [21]
Citations
Cites
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
MCCORMICK, P. W., STEWART, M., GOETTING, M. G., DUJOVNY, M., LEWIS, G., & AUSMAN, J. I. (1991) · Critical Care Medicine · doi:10.1097/00003246-199101000-00020 · Cited by 322
Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia
Hampson, N. B., & Piantadosi, C. A. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2449 · Cited by 300
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans.
McCormick, P. W., Stewart, M., Goetting, M. G., & Balakrishnan, G. (1991) · Stroke · doi:10.1161/01.str.22.5.596 · Cited by 251
Irwin, M. S., THORNILEY, M. S., Doré, C. J., & Green, C. J. (1995) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(95)90024-1 · Cited by 141
An observational study of near-infrared spectroscopy during carotid endarterectomy
Kirkpatrick, P. J., Smielewski, P., Whitfield, P. C., Czosnyka, M., Menon, D. K., & Pickard, J. D. (1995) · Journal of neurosurgery · doi:10.3171/jns.1995.82.5.0756 · Cited by 129
Perfusion imaging of skin island flap blood flow by a scanning laser-Doppler technique
Arnold, F., He, C., Jia, C., & Cherry, G. W. (1995) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(95)90065-9 · Cited by 49
McCormick, P. W., Stewart, M., Ray, P. A., Lewis, G. D., Dujovny, M., & Ausman, J. I. (1991) · Neurological Research · doi:10.1080/01616412.1991.11739967 · Cited by 41
Oxygenation and Blood Volume Changes in Flaps According to Near-Infrared Spectrophotometry
Hayden, R. E., Tavill, M. A., Nioka, S., Kitai, T., & Chance, B. (1996) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1996.01890240055012 · Cited by 34
Tissue Oxygen Tension Measurement for Monitoring Musculocutaneous and Cutaneous Flaps
Hjortdal, V. E., Awwad, A. M., Gottrup, F., KIRKEGAARD, L., & Gellett, S. (1990) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844319009004516 · Cited by 18
Cited by
Noninvasive monitoring of peripheral perfusion
Lima, A., & Bakker, J. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2790-2 · Cited by 409
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294
Yu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
“oxygen saturation for the deeper (muscle/brain) region of interest.(21) The predominant commercial incarnation of this SR method historically is the Medtronic INVOSTM and more recently the FORE-SIGHT ELITE and the Nonin EQUANOXTM systems.”
MethodHoffman, G. M., Stuth, E. A., Jaquiss, R. D., Vanderwal, P. L., Staudt, S. R., Troshynski, T. J., Ghanayem, N. S., & Tweddell, J. S. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.08.021 · Cited by 197
Metadata
- Authors
- Muellner, T., Nikolic, A., Schramm, W., & Vecsei, V.
- ORCID
- Muellner, Thomas
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 1999-06
- Volume
- 46
- Issue
- 6
- Pages
- 1082-1084
- ISSN
- 1079-6061
- OpenAlex
- W1972316677
- Cited by
- 34
- References
- 13
- Citations by year
- 2025: 2 · 2022: 1 · 2019: 1 · 2018: 1 · 2017: 2 · 2014: 1 · 2012: 2
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- near-infrared spectroscopy, muscle oxygenation, flap monitoring, free flap, flap failure, tourniquet ischemia, arterial occlusion, venous occlusion, non-invasive monitoring
- MeSH terms
- Adult, Female, Humans, Male, Muscles, Oximetry, Oxygen, Vascular Diseases, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Instrument That Uses Near-Infrared Spectroscopy for the Monitoring of Human Muscle Oxygenation. https://app.cochat.ai/papers/10.1097/00005373-199906000-00021
- The paper
- Muellner, T., Nikolic, A., Schramm, W., & Vecsei, V. (1999). New Instrument That Uses Near-Infrared Spectroscopy for the Monitoring of Human Muscle Oxygenation. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/00005373-199906000-00021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.