Effect of a Chitosan-Based Hemostatic Dressing on Blood Loss and Survival in a Model of Severe Venous Hemorrhage and Hepatic Injury in Swine

Pusateri, Anthony E., McCarthy, Simon J., Gregory, Kenton W., Harris, Richard A., Cardenas, Luis, McManus, Albert T., Goodwin, Cleon W.·2003·The Journal of Trauma: Injury, Infection, and Critical Care

Abstract

BACKGROUND: Hemorrhage is a leading cause of death from trauma. An advanced hemostatic dressing could augment available hemostatic methods. We studied the effects of a new chitosan dressing on blood loss, survival, and fluid use after severe hepatic injury in swine. METHODS: Swine received chitosan dressings or gauze sponges. Standardized, severe liver injuries were induced. After 30 seconds, dressings were applied and resuscitation initiated. Blood loss, hemostasis, resuscitation volume, and 60-minute survival were quantified. RESULTS: Posttreatment blood loss was reduced ( p< 0.01) in the chitosan group (264 mL; 95% confidence interval [CI], 82-852 mL) compared with the gauze group (2,879 mL; 95% CI, 788-10,513 mL). Fluid use was reduced ( p= 0.03) in the chitosan group (1,793 mL; 95% CI, 749-4,291) compared with the gauze group (6,614 mL; 95% CI, 2,519-17,363 mL). Survival was seven of eight and two of even in the chitosan and gauze groups ( p= 0.04), respectively. Hemostasis was improved in the chitosan group ( p= 0.03). CONCLUSION: A chitosan dressing reduced hemorrhage and improved survival after severe liver injury in swine. Further studies are warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005373-200301000-00023

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 311

Metadata

Authors
Pusateri, A. E., McCarthy, S. J., Gregory, K. W., Harris, R. A., Cardenas, L., McManus, A. T., & Goodwin, C. W.
Venue
The Journal of Trauma: Injury, Infection, and Critical Care
Published
2003-01
Volume
54
Issue
1
Pages
177-182
ISSN
0022-5282 (ISSN-L)
OpenAlex
W2073420138
Cited by
311
References
22
FWCI
4.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a Chitosan-Based Hemostatic Dressing on Blood Loss and Survival in a Model of Severe Venous Hemorrhage and Hepatic Injury in Swine. https://app.cochat.ai/papers/10.1097/00005373-200301000-00023
The paper
Pusateri, A. E., McCarthy, S. J., Gregory, K. W., Harris, R. A., Cardenas, L., McManus, A. T., & Goodwin, C. W. (2003). Effect of a Chitosan-Based Hemostatic Dressing on Blood Loss and Survival in a Model of Severe Venous Hemorrhage and Hepatic Injury in Swine. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/00005373-200301000-00023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.