CoChat

Assessment of the Aerosport TEEM 100 Portable Metabolic Measurement System

Open access
WIDEMAN, LAURIE, STOUDEMIRE, NANCY M., PASS, KIMBERLY A., McGINNES, CHRISTINA L., GAESSER, GLENN A., WELTMAN, ARTHUR · 1996 · Medicine & Science in Sports & Exercise
Cited by 56

The DOI matches its Crossref record.

Abstract

The present study evaluated the utility of a portable metabolic measurement system, the Aerosport TEEM 100. A total of 505 data points [242 from incremental (INC) and 263 from constant load (CL) exercise] were collected on 12 subjects (age = 25 +/- 4 yr), by placing the Aerosport TEEM 100 medium flow pneumotach and mouthpiece in-line with a validated system, the Rayfield system. When VO2 values were separated into categories (< 1.5, 1.5-2.0, 2.0-2.5, 2.5-3.0, > 3.0 l.min-1), there was a small but statistically significant difference between the two metabolic measurement systems for VO2, VCO2, VE, RER, %ECO2, and %EO2 during both INC and CL exercise and measurement error for VO2 ranged between 2% and 11%. Correlations for VO2 values during INC and CL exercise between the two systems were r = 0.95 (SEest +/- 0.18 l.min-1) and r = 0.96 (SEest +/- 0.29 l.min-1), respectively. Correlations for RER were r = 0.82 (SEest +/- 0.08) and r = 0.47 (SEest +/- 0.11), for INC and CL, respectively. Results from the present investigation indicate that the Aerosport TEEM 100 has utility for the assessment of VO2, but the estimation of carbohydrate and fat utilization from RER should be used with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199604000-00017

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 56

Metadata

Authors
WIDEMAN, L., STOUDEMIRE, N. M., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A.
Venue
Medicine & Science in Sports & Exercise
Published
1996-04
Volume
28
Issue
4
Pages
509-515
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1995800865
Cited by
56
References
0
FWCI
2.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the Aerosport TEEM 100 Portable Metabolic Measurement System. https://app.cochat.ai/papers/10.1097/00005768-199604000-00017
The paper
WIDEMAN, L., STOUDEMIRE, N. M., PASS, K. A., McGINNES, C. L., GAESSER, G. A., & WELTMAN, A. (1996). Assessment of the Aerosport TEEM 100 Portable Metabolic Measurement System. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199604000-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.