A new method for monitoring hydration at high altitude by bioimpedance analysis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Our study evaluated the performance of a graphical method for monitoring the fluid variation at high altitude in seven adult Caucasian male subjects (average age 25 yr, average height 177 cm). The graphical approach is called the Resistance-Reactance (RXc) graph method and is based on standard bioimpedance analysis (tetrapolar, 50 kHz frequency). Measurements were taken at sea level before the expedition, at 5050 m after 1 wk and 3 wk, and again at sea level after descent. Plasma and urine electrolytes, osmolalities, and the free-water clearance were determined by standard methods. All climbers had baseline impedance vectors within the reference 95% tolerance ellipse for the Italian male population. The high altitude dehydration caused a significant lengthening of vectors, which after descent underwent a significant shortening and returned close to the baseline values. Average urine volume increased by 1.4 l.d-1 in the first week and average body weight decreased by 4.4 kg after 3 wk. The RXc graph method could be useful in the planning of the individual climber's appropriate dehydration and fluid intake at altitude since a feedback control of the hydration is allowed without any assumption of body composition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Is the Impedance index (ht2/R) significant in predicting total body water?
Kushner, R., Schoeller, D., Fjeld, C., & Danford, L. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.5.835 · Cited by 374
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“[64,65] to estimate the hydration status using height indexed resistance and reactance data (R-Xc graph) from bioimpedance measurements.”
MethodRondanelli, M., Klersy, C., Terracol, G., Talluri, J., Maugeri, R., Guido, D., Faliva, M. A., Solerte, B. S., Fioravanti, M., Lukaski, H., et al. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.113357 · Cited by 412
Kavouras, S. A. (2002) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/00075197-200209000-00010 · Cited by 322
Assessment of hydration status in a large population
Baron, S., Courbebaisse, M., Lepicard, E. M., & Friedlander, G. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003213 · Cited by 166
Metadata
- Authors
- PICCOLI, A., PIAZZA, P., NOVENTA, D., PILLON, L., & ZACCARIA, M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1996-12
- Volume
- 28
- Issue
- 12
- Pages
- 1517-1522
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2088475987
- Cited by
- 53
- References
- 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new method for monitoring hydration at high altitude by bioimpedance analysis. https://app.cochat.ai/papers/10.1097/00005768-199612000-00012
- The paper
- PICCOLI, A., PIAZZA, P., NOVENTA, D., PILLON, L., & ZACCARIA, M. (1996). A new method for monitoring hydration at high altitude by bioimpedance analysis. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199612000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.