Automated ??VO2max calibrator for open-circuit indirect calorimetry systems
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The complete calibration of indirect calorimetry systems involves simultaneous checks of gas analyzers, volume device, and software, and this requires a machine that can mimic accurately and precisely the ventilation and expired gases of an athlete. While previous calibrators have been built successfully, none have matched the ventilatory flows produced by athletes during high intensity exercise. A calibrator able to simulate high aerobic power (VO2max calibrator) was fabricated and tested against conventional indirect calorimetry systems that use chain-compensated gasometers to measure expired volume (VE systems) and calibrated electronic gas analyzers. The calibrator was also checked against a system that measures inspired volume (VI system) with a turbine ventilometer. The pooled data from both VE and VI systems for predicted VO2 ranging from 2.9 to 7.9 L.min-1 and ventilation ranging from 89 to 246 L.min-1 how that the absolute accuracy (bias) of values measured by conventional indirect calorimetry systems compared with those predicted by the calibrator was excellent. The bias was < 35 mL.min-1 for VO2 and carbon dioxide production, < 0.50 L.min-1 for ventilator (VE BTPS), -0.02% absolute for the percentage of expired O2 and +0.02% absolute for the percentage of expired CO2. Overall, the precision of the measured VO2, VCO2, and VE BTPS was approximately 1%. This VO2max calibrator is a versatile device that can be used for routine calibration of most indirect calorimetry systems that assess the ventilation and aerobic power of athletes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
Biological variability in maximum aerobic power.
KATCH, V. L., SADY, S. S., & FREEDSON, P. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198201000-00004 · Cited by 187
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
The Physical and Physiological Demands of Basketball Training and Competition
Montgomery, P. G., Pyne, D. B., & Minahan, C. L. (2010) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.5.1.75 · Cited by 434
Effects of heat stress on physiological responses and exercise performance in elite cyclists
Tatterson, A. J., Hahn, A. G., Martini, D. T., & Febbraio, M. A. (2000) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(00)80080-8 · Cited by 314
Effect of different protocols of caffeine intake on metabolism and endurance performance
Cox, G. R., Desbrow, B., Montgomery, P. G., Anderson, M. E., Bruce, C. R., Macrides, T. A., Martin, D. T., Moquin, A., Roberts, A., Hawley, J. A., et al. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00249.2002 · Cited by 309
“During the maximal test, which typically lasted between 10-12 min, subjects inspired air through a two-way Hans Rudolf valve attached to a custom built automated Douglas bag gas analysis system (Australian Institute of Sport, ACT, Australia) for which calibration and operation details have been previously described (1…”
MethodInterval training program optimization in highly trained endurance cyclists
LAURSEN, P. B., SHING, C. M., PEAKE, J. M., COOMBES, J. S., & JENKINS, D. G. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200211000-00017 · Cited by 253
Reliability and Variability of Running Economy in Elite Distance Runners
SAUNDERS, P. U., PYNE, D. B., TELFORD, R. D., & HAWLEY, J. A. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000145468.17329.9f · Cited by 227
Automated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Burke, L. M., Angus, D. J., Cox, G. R., Cummings, N. K., Febbraio, M. A., Gawthorn, K., Hawley, J. A., Minehan, M., Martin, D. T., & Hargreaves, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.6.2413 · Cited by 190
Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system
Macfarlane, D. J., & Wong, P. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2230-7 · Cited by 167
“…studies on the MM3B have been performed against the DBM (Brehm et al. 2004; Prieur et al. 2003; Vogler et al. 2010), and despite its limitations the DBM is often considered to be the criterion (Hodges et al. 2005), especially when precise metabolic calibrators are not available (Gore et al. 1997).”
BackgroundMethodMetabolic and mitogenic signal transduction in human skeletal muscle after intense cycling exercise
Yu, M., Stepto, N. K., Chibalin, A. V., Fryer, L. G. D., Carling, D., Krook, A., Hawley, J. A., & Zierath, J. R. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.034223 · Cited by 159
“Before and after the study an automated high-capacity calibrator for open-circuit indirect calorimetry was used to simultaneously check the gas analysers, volume device and software of the custom-built system (Gore et al. 1997).”
MethodINFLUENCE OF HIGH-INTENSITY INTERVAL TRAINING ON ADAPTATIONS IN WELL-TRAINED CYCLISTS
LAURSEN, P. B., SHING, C. M., PEAKE, J. M., COOMBES, J. S., & JENKINS, D. G. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200508000-00008 · Cited by 158
BURKE, L. M., HAWLEY, J. A., ANGUS, D. J., COX, G. R., CLARK, S. A., CUMMINGS, N. K., DESBROW, B., & HARGREAVES, M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200201000-00014 · Cited by 131
The energy cost of running on grass compared to soft dry beach sand
Pinnington, H. C., & Dawson, B. (2001) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(01)80051-7 · Cited by 118
Effect of altering substrate availability on metabolism and performance during intense exercise
Hawley, J. A., Burke, L. M., Angus, D. J., Fallon, K. E., Martin, D. T., & Febbraio, M. A. (2000) · British Journal of Nutrition · doi:10.1017/s0007114500002440 · Cited by 63
“Before and after the study, an automated high-capacity calibrator for opencircuit indirect calorimetry was used to simultaneously check the gas analysers, volume device and software of the custom built system (Gore et al. 1997).”
Method
Metadata
- Authors
- GORE, C. J., CATCHESIDE, P. G., FRENCH, S. N., BENNETT, J. M., & LAFORGIA, J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-08
- Volume
- 29
- Issue
- 8
- Pages
- 1095-1103
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2047243875
- Cited by
- 62
- References
- 2
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.