The DOI matches its Crossref record.
Telemetry pill measurement of core temperature in humans during active heating and cooling
Abstract
PURPOSE: This study compared the agreement between core temperature measurements obtained using an ingestible temperature pill telemetry system (Tpill) with those obtained from rectal (Tre) and esophageal (Tes) thermocouples under conditions of increasing and decreasing body temperature. METHODS: Four men and five women (age 25+/-2 yr, BSA 1.81+/-0.05 m2, VO2 peak 3.1+/-0.4 L x min[-1]) participated in four 3-h trials: cold (18 degrees C) water rest (CWR), cold water exercise (CWE), warm (36 degrees C) water rest (WWR), and warm water exercise (WWE). Subjects were immersed to the neck for each trial. During resting trials, subjects sat quietly. During exercise trials, subjects completed three bouts of 15 min of rest, followed by 45 min of exercise on a cycle ergometer at 50% of peak oxygen uptake. The temperature pill was taken 10-12 h before testing, after which the subjects fasted. RESULTS: The trials created conditions of constantly decreasing (CWR) or increasing (WWR) core temperature, as well as periods of oscillating core temperature (CWE and WWE). Root mean squared deviation (RMSD) was calculated for each pair of measurements (Tpill vs Tre, Tpill vs Tes, Tre vs Tes) for each trial. An RMSD of "0" indicates perfect agreement; as RMSD increases, agreement worsens. On CWR, the RMSD for Tpill-Tes (0.23+/-0.04) was lower (P < 0.05) than for Tpill-Tre (0.43+/-0.10) or Tre-Tes (0.46+/-0.09). There were no significant differences in RMSD between measurement pairs on any other trial (average RMSD = 0.26 degrees C). Telemetry pill temperature and response time tended to be intermediate between Tre and Tes. CONCLUSION: These results suggest the telemetry pill system provides a valid measurement of core temperature during conditions of decreasing as well as increasing body temperature and during steady state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Byrne, C., & Lim, C. L. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.026344 · Cited by 456
Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Lim, C. L., Byrne, C., & Lee, J. K. (2008) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v37n4p347 · Cited by 373
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Circadian rhythm of wrist temperature in normal-living subjects
Sarabia, J. A., Rol, M. A., Mendiola, P., & Madrid, J. A. (2008) · Physiology & Behavior · doi:10.1016/j.physbeh.2008.08.005 · Cited by 222
Wang, F., Kuklane, K., Gao, C., & Holmér, I. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/2/007 · Cited by 83
Metadata
- Authors
- O'BRIEN, C., HOYT, R. W., BULLER, M. J., CASTELLANI, J. W., & YOUNG, A. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1998-03
- Volume
- 30
- Issue
- 3
- Pages
- 468-472
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1966410841
- Cited by
- 219
- References
- 0
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Telemetry pill measurement of core temperature in humans during active heating and cooling. https://app.cochat.ai/papers/10.1097/00005768-199803000-00020
- The paper
- O'BRIEN, C., HOYT, R. W., BULLER, M. J., CASTELLANI, J. W., & YOUNG, A. J. (1998). Telemetry pill measurement of core temperature in humans during active heating and cooling. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199803000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.