CoChat

Effect of fluid intake volume on 2-h running performances in a 25??C environment

DARIES, HALEY N., NOAKES, TIMOTHY D., DENNIS, STEVEN C. · 2000 · Medicine & Science in Sports & Exercise
Cited by 78

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE: In this study, we examined the effects of greater than ad libitum rates of fluid intake on 2-h running performances. METHODS: Eight male distance runners performed three runs on a treadmill at 65% of peak oxygen uptake (VO2peak) for 90 min and then ran "as far as possible" in 30 min in an air temperature of 25 degrees C, a relative humidity of 55% and a wind speed of 13-15 km x h(-1). During the runs, the subjects drank a 6.9% carbohydrate (CHO)-electrolyte solution either ad libitum or in set volumes of 150 or 350 mL x 70 kg(-1) body mass (approximately 130 or 300 mL) every 15-20 min. RESULTS: Higher (approximately 0.9 vs 0.4 L x h(-1)) rates of fluid intake in the 350 mL x 70 kg(-1) trial than in the other trials had minimal effects on the subjects' urine production (approximately 0.1 L x h(-1)), sweat rates (approximately 1.2 L x h(-1)), declines in plasma volume (approximately 8%), and rises in serum osmolality (approximately 5 mosmol x L(-1)) and Na+ concentrations (approximately 7 mEq x L(-1)). A greater (approximately 1.0 vs 0.5 g x min(-1)) rate of CHO ingestion in the 350 mL x 70 kg(-1) trial than in the other trials also did not affect plasma concentrations of glucose (> or = 5 mmol x L(-1)) and lactate (approximately 3 mmol x L(-1)) during the performance runs. In all three performance runs, increases in running speeds from approximately 14 to 15-16 km x h(-1) and rises in exercise intensities from approximately 65% to 75% of VO2peak elevated plasma lactate concentrations from approximately 1.5 to 3 mmol x L(-1) and accelerated CHO oxidation from approximately 13 to 15 mmol x min(-1). The only effect of the additional intake of approximately 1.0 L of fluid in the 350 mL x 70 kg(-1) trial was to produce such severe gastrointestinal discomfort that two of the eight subjects failed to complete their performance runs. CONCLUSION: Greater rates of fluid ingestion had no measurable effects on plasma volume and osmolality and did not improve 2-h running performances in a 25 degrees C environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-200010000-00019

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 78

Metadata

Authors
DARIES, H. N., NOAKES, T. D., & DENNIS, S. C.
Venue
Medicine & Science in Sports & Exercise
Published
2000-10
Volume
32
Issue
10
Pages
1783-1789
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2012989352
Cited by
78
References
7
FWCI
1.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of fluid intake volume on 2-h running performances in a 25??C environment. https://app.cochat.ai/papers/10.1097/00005768-200010000-00019
The paper
DARIES, H. N., NOAKES, T. D., & DENNIS, S. C. (2000). Effect of fluid intake volume on 2-h running performances in a 25??C environment. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200010000-00019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.