An Institutional Experience with Cervical Vagus Nerve Trunk Stimulation for Medically Refractory Epilepsy: Rationale, Technique, and Outcome

Amar, Arun Paul, Heck, Christi N., Levy, Michael L., Thomas, Smith, DeGiorgio, Christopher M., Oviedo, Sandra, Apuzzo, Michael L.J. · 1998 · Neurosurgery

Abstract

OBJECTIVE: Intermittent stimulation of the left cervical vagus nerve trunk is emerging as a novel adjunct in the treatment of medically refractory seizures. We sought to evaluate theoretical and practical issues attendant to this concept. We review the anatomic and physiological background arguing for clinical application of vagus nerve stimulation, discuss salient aspects of patient selection and the nuances of surgical technique, and present our observations of and results from application of the method. METHODS: Each of 18 patients with medically refractory epilepsy and at least six complex partial or secondarily generalized seizures per month underwent placement of a NeuroCybernetic Prosthesis pulse generator (Cyberonics, Webster, TX) in the chest, connected to helical platinum leads applied to the left cervical vagus nerve trunk. The patients were then randomized in a double-blinded fashion to receive either high (presumably therapeutic) or low (presumably less therapeutic) levels of vagus nerve stimulation. Reduction in seizure frequency, global assessments of quality of life, physiological measurements, and adverse events were recorded during a 3-month period. Patients in the low group were then crossed over to high-stimulation paradigms during a 15-month extension trial. RESULTS: All operations were successful, uneventful, and without adverse postoperative sequelae. One patient was excluded from analysis because of inadequate seizure calendars. Of the seven patients initially assigned to high stimulation, the mean reduction in seizure frequency was 71% at 3 months and 81% at 18 months. Five (72%) of these patients had a greater than 75% reduction in seizure frequency, and one (14%) remained seizure-free after more than 1.5 years of follow-up. The mean reduction in seizure frequency among the low-stimulation group was only 6% at 3 months. No serious complications, device failures, or physiological perturbations occurred. CONCLUSION: In our experience, vagus nerve stimulation has proven to be a safe, feasible, and potentially effective method of reducing seizures in select patient populations. However, the elements of strict definition for the application of the method require further study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-199812000-00001

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 164

Metadata

Authors
Amar, A. P., Heck, C. N., Levy, M. L., Thomas, S., DeGiorgio, C. M., Oviedo, S., & Apuzzo, M. L. J.
Venue
Neurosurgery
Published
1998-12
Volume
43
Issue
6
Pages
1265-1276
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2024297318
Cited by
164
References
1
FWCI
4.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Institutional Experience with Cervical Vagus Nerve Trunk Stimulation for Medically Refractory Epilepsy: Rationale, Technique, and Outcome. https://app.cochat.ai/papers/10.1097/00006123-199812000-00001
The paper
Amar, A. P., Heck, C. N., Levy, M. L., Thomas, S., DeGiorgio, C. M., Oviedo, S., & Apuzzo, M. L. J. (1998). An Institutional Experience with Cervical Vagus Nerve Trunk Stimulation for Medically Refractory Epilepsy: Rationale, Technique, and Outcome. Neurosurgery. https://doi.org/10.1097/00006123-199812000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.