Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of Anatomic and Neurophysiological Methods for Subthalamic Nucleus Targeting

Zonenshayn, Martin, Rezai, Ali R., Mogilner, Alon Y., Beric, Aleksandar, Sterio, Djordje, Kelly, Patrick J.·2000·Neurosurgery

Abstract

OBJECTIVE: The subthalamic nucleus (STN) has recently become the surgical target of choice for the treatment of medically refractory idiopathic Parkinson's disease. A number of anatomic and physiological targeting methods have been used to localize the STN. We retrospectively reviewed the various anatomic targeting methods and compared them with the final physiological target in 15 patients who underwent simultaneous bilateral STN implantation of deep brain stimulators. METHODS: The x, y, and z coordinates of our localizing techniques were analyzed for 30 STN targets. Our final targets, as determined by single-cell microelectrode recording, were compared with the following: 1) targets selected on coronal magnetic resonance inversion recovery and T2-weighted imaging sequences, 2) the center of the STN on a digitized scaled Schaltenbrand-Wahren stereotactic atlas, 3) targeting based on a point 13 mm lateral, 4 mm posterior, and 5 mm inferior to the midcommissural point, and 4) a composite target based on the above methods. RESULTS: All anatomic methods yielded targets that were statistically significantly different (P < 0.001) from the final physiological targets. The average distance error between the final physiological targets and the magnetic resonance imaging-derived targets was 2.6 +/- 1.3 mm (mean +/- standard deviation), 1.7 +/- 1.1 mm for the atlas-based method, 1.5 +/- 0.8 mm for the indirect midcommissural method, and 1.3 +/- 1.1 mm for the composite method. Once the final microelectrode-refined target was determined on the first side, the final target for the contralateral side was 1.3 +/- 1.2 mm away from its mirror image. CONCLUSION: Although all anatomic targeting methods provide accurate STN localization, a combination of the three methods offers the best correlation with the final physiological target. In our experience, direct magnetic resonance targeting was the least accurate method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-200008000-00005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 201

Metadata

Authors
Zonenshayn, M., Rezai, A. R., Mogilner, A. Y., Beric, A., Sterio, D., & Kelly, P. J.
Venue
Neurosurgery
Published
2000-08-01
Volume
47
Issue
2
Pages
282-294
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2049018094
Cited by
201
References
1
FWCI
6.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Anatomic and Neurophysiological Methods for Subthalamic Nucleus Targeting. https://app.cochat.ai/papers/10.1097/00006123-200008000-00005
The paper
Zonenshayn, M., Rezai, A. R., Mogilner, A. Y., Beric, A., Sterio, D., & Kelly, P. J. (2000). Comparison of Anatomic and Neurophysiological Methods for Subthalamic Nucleus Targeting. Neurosurgery. https://doi.org/10.1097/00006123-200008000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.