Comparison of Anatomic and Neurophysiological Methods for Subthalamic Nucleus Targeting
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The subthalamic nucleus (STN) has recently become the surgical target of choice for the treatment of medically refractory idiopathic Parkinson's disease. A number of anatomic and physiological targeting methods have been used to localize the STN. We retrospectively reviewed the various anatomic targeting methods and compared them with the final physiological target in 15 patients who underwent simultaneous bilateral STN implantation of deep brain stimulators. METHODS: The x, y, and z coordinates of our localizing techniques were analyzed for 30 STN targets. Our final targets, as determined by single-cell microelectrode recording, were compared with the following: 1) targets selected on coronal magnetic resonance inversion recovery and T2-weighted imaging sequences, 2) the center of the STN on a digitized scaled Schaltenbrand-Wahren stereotactic atlas, 3) targeting based on a point 13 mm lateral, 4 mm posterior, and 5 mm inferior to the midcommissural point, and 4) a composite target based on the above methods. RESULTS: All anatomic methods yielded targets that were statistically significantly different (P < 0.001) from the final physiological targets. The average distance error between the final physiological targets and the magnetic resonance imaging-derived targets was 2.6 +/- 1.3 mm (mean +/- standard deviation), 1.7 +/- 1.1 mm for the atlas-based method, 1.5 +/- 0.8 mm for the indirect midcommissural method, and 1.3 +/- 1.1 mm for the composite method. Once the final microelectrode-refined target was determined on the first side, the final target for the contralateral side was 1.3 +/- 1.2 mm away from its mirror image. CONCLUSION: Although all anatomic targeting methods provide accurate STN localization, a combination of the three methods offers the best correlation with the final physiological target. In our experience, direct magnetic resonance targeting was the least accurate method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
Benabid, A. L., Pollak, P., Gao, D., Hoffmann, D., Limousin, P., Gay, E., Payen, I., & Benazzouz, A. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.2.0203 · Cited by 1,134
Leksell's posteroventral pallidotomy in the treatment of Parkinson's disease
Laitinen, L. V., Bergenheim, A. T., & Hariz, M. I. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.1.0053 · Cited by 1,081
Atlas for Stereotaxy of the Human Brain
Schaltenbrand, G., & Wahren, W. (1977) · Medical Entomology and Zoology · Cited by 955
Atlas for stereotaxy of the human brain
Bosch, D. A. (1978) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(78)80027-4 · Cited by 867
Neurophysiological identification of the subthalamic nucleus in surgery for Parkinson's disease
Hutchison, W. D., Allan, R. J., Opitz, H., Levy, R., Dostrovsky, J. O., Lang, A. E., & Lozano, A. M. (1998) · Annals of Neurology · doi:10.1002/ana.410440407 · Cited by 702
Multiarchitectonic and stereotactic atlas of the human thalamus
Morel, A., Magnin, M., & Jeanmonod, D. (1997) · The Journal of Comparative Neurology · doi:10.1002/(sici)1096-9861(19971103)387:4<588::aid-cne8>3.0.co;2-z · Cited by 640
Kumar, R., Lozano, A. M., Kim, Y. J., Hutchison, W. D., Sime, E., Halket, E., & Lang, A. E. (1998) · Neurology · doi:10.1212/wnl.51.3.850 · Cited by 634
Subthalamic nucleus or internal pallidal stimulation in young onset Parkinson's disease
Krack, P. (1998) · Brain · doi:10.1093/brain/121.3.451 · Cited by 608
Acute and Long-Term Effects of Subthalamic Nucleus Stimulation in Parkinson's Disease
Benabid, A. L., Pollak, P., Gross, C., Hoffmann, D., Benazzouz, A., Gao, D. M., Laurent, A., Gentil, M., & Perret, J. (1994) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098600 · Cited by 532
Cited by
McIntyre, C. C., Mori, S., Sherman, D. L., Thakor, N. V., & Vitek, J. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.033 · Cited by 492
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Gross, R. E., Krack, P., Rodriguez-Oroz, M. C., Rezai, A. R., & Benabid, A.-L. (2006) · Movement Disorders · doi:10.1002/mds.20960 · Cited by 324
Self-citationComplications of Deep Brain Stimulation Surgery
Beric, A., Kelly, P. J., Rezai, A., Sterio, D., Mogilner, A., Zonenshayn, M., & Kopell, B. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000064600 · Cited by 316
Self-citationSaint-Cyr, J. A., Hoque, T., Pereira, L. C. M., Dostrovsky, J. O., Hutchison, W. D., Mikulis, D. J., Abosch, A., Sime, E., Lang, A. E., & Lozano, A. M. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.5.1152 · Cited by 291
Most effective stimulation site in subthalamic deep brain stimulation for Parkinson's disease
Herzog, J., Fietzek, U., Hamel, W., Morsnowski, A., Steigerwald, F., Schrader, B., Weinert, D., Pfister, G., Müller, D., Mehdorn, H. M., et al. (2004) · Movement Disorders · doi:10.1002/mds.20056 · Cited by 253
Gallay, M. N., Jeanmonod, D., Liu, J., & Morel, A. (2008) · Brain Structure and Function · doi:10.1007/s00429-007-0170-0 · Cited by 251
“2000; Wichmann and DeLong 2003), and peroperative recordings in patients undergoing surgery (Lenz et al. 1994; Jeanmonod et al. 1996; Lozano et al. 1997; Hutchison et al. 1998; Vitek et al. 1998; Magnin et al. 2000, 2001a; Zonenshayn et al. 2000; Garonzik et al. 2002; Kobayashi et al. 2003).”
BackgroundDeep Brain Stimulation in Epilepsy
Loddenkemper, T., Pan, A., Neme, S., Baker, K. B., Rezai, A. R., Dinner, D. S., Montgomery, E. B., & Lüders, H. O. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200111000-00002 · Cited by 212
“Additionally, penetrations too lateral or too medial result in traversing only a short segment of the STN instead of an optimum of 5 to 6 mm. Microelectrode recordings are considered the current gold standard in localizing the STN (Zonenshayn et al., 2000).”
BackgroundSelf-citationYelnik, J., Damier, P., Demeret, S., Gervais, D., Bardinet, E., Bejjani, B.-P., François, C., Houeto, J.-L., Arnulf, I., Dormont, D., et al. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.1.0089 · Cited by 202
Spatial steering of deep brain stimulation volumes using a novel lead design
Martens, H. C. F., Toader, E., Decré, M. M. J., Anderson, D. J., Vetter, R., Kipke, D. R., Baker, K. B., Johnson, M. D., & Vitek, J. L. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.07.026 · Cited by 195
Hamel, W. (2003) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.74.8.1036 · Cited by 179
Godinho, F., Thobois, S., Magnin, M., Guenot, M., Polo, G., Benatru, I., Xie, J., Salvetti, A., Garcia-Larrea, L., Broussolle, E., et al. (2006) · Journal of Neurology · doi:10.1007/s00415-006-0222-z · Cited by 176
“Regarding the precise determination of the STN borders, microelectrode recording techniques are best suited [28, 41, 59, 72, 79].”
Deep brain stimulation for Parkinson's disease: Surgical issues
Rezai, A. R., Kopell, B. H., Gross, R. E., Vitek, J. L., Sharan, A. D., Limousin, P., & Benabid, A.-L. (2006) · Movement Disorders · doi:10.1002/mds.20956 · Cited by 176
Self-citationAn update on best practice of deep brain stimulation in Parkinson’s disease
Hartmann, C. J., Fliegen, S., Groiss, S. J., Wojtecki, L., & Schnitzler, A. (2019) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756286419838096 · Cited by 173
Morrison, C. (2004) · Archives of Clinical Neuropsychology · doi:10.1016/s0887-6177(03)00004-0 · Cited by 160
“The final coordinates for the implanted electrode were fine-tuned based on the patterns of microelectrode recordings and the effects of test stimulation (Weisz & Yang, 1998; Zonenshayn et al., 2000).”
Metadata
- Authors
- Zonenshayn, M., Rezai, A. R., Mogilner, A. Y., Beric, A., Sterio, D., & Kelly, P. J.
- Venue
- Neurosurgery
- Published
- 2000-08-01
- Volume
- 47
- Issue
- 2
- Pages
- 282-294
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2049018094
- Cited by
- 201
- References
- 35
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.