Serial Intraoperative Magnetic Resonance Imaging of Brain Shift
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: A major shortcoming of image-guided navigational systems is the use of preoperatively acquired image data, which does not account for intraoperative changes in brain morphology. The occurrence of these surgically induced volumetric deformations ("brain shift") has been well established. Maximal measurements for surface and midline shifts have been reported. There has been no detailed analysis, however, of the changes that occur during surgery. The use of intraoperative magnetic resonance imaging provides a unique opportunity to obtain serial image data and characterize the time course of brain deformations during surgery. METHODS: The vertically open intraoperative magnetic resonance imaging system (SignaSP, 0.5 T; GE Medical Systems, Milwaukee, WI) permits access to the surgical field and allows multiple intraoperative image updates without the need to move the patient. We developed volumetric display software (the 3D Slicer) that allows quantitative analysis of the degree and direction of brain shift. For 25 patients, four or more intraoperative volumetric image acquisitions were extensively evaluated. RESULTS: Serial acquisitions allow comprehensive sequential descriptions of the direction and magnitude of intraoperative deformations. Brain shift occurs at various surgical stages and in different regions. Surface shift occurs throughout surgery and is mainly attributable to gravity. Subsurface shift occurs during resection and involves collapse of the resection cavity and intraparenchymal changes that are difficult to model. CONCLUSION: Brain shift is a continuous dynamic process that evolves differently in distinct brain regions. Therefore, only serial imaging or continuous data acquisition can provide consistently accurate image guidance. Furthermore, only serial intraoperative magnetic resonance imaging provides an accurate basis for the computational analysis of brain deformations, which might lead to an understanding and eventual simulation of brain shift for intraoperative guidance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multi-modal volume registration by maximization of mutual information
Wells, W. M., Viola, P., Atsumi, H., Nakajima, S., & Kikinis, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80004-9 · Cited by 1,959
Self-citation(2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00937-3 · Cited by 1,048
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Constitutive modelling of brain tissue: Experiment and theory
Miller, K., & Chinzei, K. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00092-4 · Cited by 526
(1999) · Lecture Notes in Computer Science · doi:10.1007/10704282 · Cited by 489
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00066 · Cited by 404
Craniotomy for Tumor Treatment in an Intraoperative Magnetic Resonance Imaging Unit
Black, P. M., Alexander, E., Martin, C., Moriarty, T., Nabavi, A., Wong, T. Z., Schwartz, R. B., & Jolesz, F. (1999) · Neurosurgery · doi:10.1097/00006123-199909000-00001 · Cited by 301
Self-citationPostimaging brain distortion: magnitude, correlates, and impact on neuronavigation
Dorward, N. L., Alberti, O., Velani, B., Gerritsen, F. A., Harkness, W. F. J., Kitchen, N. D., & Thomas, D. G. T. (1998) · Journal of Neurosurgery · doi:10.3171/jns.1998.88.4.0656 · Cited by 290
Frameless stereotaxic integration of CT imaging data: accuracy and initial applications.
Zinreich, S. J., Tebo, S. A., Long, D. M., Brem, H., Mattox, D. E., Loury, M. E., vander Kolk, C. A., Koch, W. M., Kennedy, D. W., & Bryan, R. N. (1993) · Radiology · doi:10.1148/radiology.188.3.8351341 · Cited by 244
Maurer, C. R., Hill, D. L. G., Martin, A. J., Liu, H., McCue, M., Rueckert, D., Lloret, D., Hall, W. A., Maxwell, R. E., Hawkes, D. J., et al. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736050 · Cited by 195
Visual assessment of the accuracy of retrospective registration of MR and CT images of the brain
Fitzpatrick, J. M., Hill, D., Shyr, Y., West, J. B., Studholme, C., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730402 · Cited by 157
Intraoperatively Updated Neuroimaging Using Brain Modeling and Sparse Data
Roberts, D. W., Miga, M. I., Hartov, A., Eisner, S. D., Lemery, J., Kennedy, F. E., & Paulsen, K. D. (1999) · Neurosurgery · doi:10.1097/00006123-199911000-00037 · Cited by 111
Effects of Brain Ventricular Shape on Periventricular Biomechanics: A Finite-element Analysis
Peña, A., Bolton, M. D., Whitehouse, H., & Pickard, J. D. (1999) · Neurosurgery · doi:10.1097/00006123-199907000-00026 · Cited by 106
Rubino, G. J., Farahani, K., McGill, D. R., et al. (2000) · Neurosurgery · doi:10.1097/00006123-200003000-00023 · Cited by 103
Seifert, V., Zimmermann, M., Trantakis, C., Vitzthum, H. E., Kühnel, K., Raabe, A., Bootz, F., Schneider, J. ‐., Schmidt, F. M., & Dietrich, J. (1999) · Acta Neurochirurgica · doi:10.1007/s007010050325 · Cited by 98
Computer Vision, Virtual Reality and Robotics in Medicine
(1995) · Springer eBooks · doi:10.1007/bfb0034926 · Cited by 88
Hata, N., Nabavi, A., Wells, W. M., Warfield, S. K., Kikinis, R., Black, P. M., & Jolesz, F. A. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200007000-00004 · Cited by 81
Self-citationComputer Vision, Virtual Reality and Robotics in Medicine
Ayache, N. (1995) · Lecture notes in computer science · doi:10.1007/978-3-540-49197-2 · Cited by 25
Cited by
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Rapid, Label-Free Detection of Brain Tumors with Stimulated Raman Scattering Microscopy
Ji, M., Orringer, D. A., Freudiger, C. W., Ramkissoon, S., Liu, X., Lau, D., Golby, A. J., Norton, I., Hayashi, M., Agar, N. Y. R., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005954 · Cited by 513
Preoperative and Intraoperative Diffusion Tensor Imaging-based Fiber Tracking in Glioma Surgery
Nimsky, C., Ganslandt, O., Hastreiter, P., Wang, R., Benner, T., Sorensen, A. G., & Fahlbusch, R. (2005) · Neurosurgery · doi:10.1227/01.neu.0000144842.18771.30 · Cited by 442
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Self-citationBrain shift in neuronavigation of brain tumors: A review
Gerard, I. J., Kersten-Oertel, M., Petrecca, K., Sirhan, D., Hall, J. A., & Collins, D. L. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.08.007 · Cited by 324
Metadata
- Authors
- Nabavi, A., Black, P. M., Gering, D. T., Westin, C.-F., Mehta, V., Pergolizzi, R. S., Ferrant, M., Warfield, S. K., Hata, N., Schwartz, R. B., Wells, W. M., Kikinis, R., & Jolesz, F. A.
- Venue
- Neurosurgery
- Published
- 2001-04-01
- Volume
- 48
- Issue
- 4
- Pages
- 787-798
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1995449991
- Cited by
- 461
- References
- 19
- FWCI
- 31.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.