Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Measurement of Intraoperative Brain Surface Deformation under a Craniotomy

Hill, Derek L.G., Maurer, Calvin R., Maciunas, Robert J., Maciunas, Robert J., Barwise, John A., Fitzpatrick, J. Michael, Wang, Matthew Y.·1998·Neurosurgery

Abstract

OBJECTIVE: Several causes of spatial inaccuracies in image-guided surgery have been carefully studied and documented for several systems. These include error in identifying the external features used for registration, geometrical distortion in the preoperative images, and error in tracking the surgical instruments. Another potentially important source of error is brain deformation between the time of imaging and the time of surgery or during surgery. In this study, we measured the deformation of the dura and brain surfaces between the time of imaging and the start of surgical resection for 21 patients. METHODS: All patients underwent intraoperative functional mapping, allowing us to measure brain surface motion at two times that were separated by nearly an hour after opening the dura but before performing resection. The positions of the dura and brain surfaces were recorded and transformed to the coordinate space of a preoperative magnetic resonance image, using the Acustar surgical navigation system (manufactured by Johnson & Johnson Professional, Inc., Randolph, MA) (the Acustar trademark and associated intellectual property rights are now owned by Picker International, Highland Heights, OH). This system performs image registration with bone-implanted markers and tracks a surgical probe by optical triangulation. RESULTS: The mean displacements of the dura and the first and second brain surfaces were 1.2, 4.4, and 5.6 mm, respectively, with corresponding mean volume reductions under the craniotomy of 6, 22, and 29 cc. The maximum displacement was greater than 10 mm in approximately one-third of the patients for the first brain surface measurement and one-half of the patients for the second. In all cases, the direction of brain shift corresponded to a "sinking" of the brain intraoperatively, compared with its preoperative position. Analysis of the measurement error revealed that its magnitude was approximately 1 to 2 mm. We observed two different patterns of the brain surface deformation field, depending on the inclination of the craniotomy with respect to gravity. Separate measurements of brain deformation within the closed cranium caused by changes in patient head orientation with respect to gravity suggested that less than 1 mm of the brain shift recorded intraoperatively could have resulted from the change in patient orientation between the time of imaging and the time of surgery. CONCLUSION: These results suggest that intraoperative brain deformation is an important source of error that needs to be considered when using surgical navigation systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-199809000-00066

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 404

Metadata

Authors
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y.
Venue
Neurosurgery
Published
1998-09
Volume
43
Issue
3
Pages
514-526
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W1484665822
Cited by
404
References
22
FWCI
42.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Intraoperative Brain Surface Deformation under a Craniotomy. https://app.cochat.ai/papers/10.1097/00006123-199809000-00066
The paper
Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y. (1998). Measurement of Intraoperative Brain Surface Deformation under a Craniotomy. Neurosurgery. https://doi.org/10.1097/00006123-199809000-00066

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.