Vision Performance With a Contact Lens Designed to Slow Myopia Progression
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Purpose: Recent research suggests multizone/dual‐focus (DF) lens corrections may aid in controlling the progression of myopia. Recently, such a soft contact lens has become commercially available in Hong Kong (MiSight, CooperVision). The purpose of the current study was to evaluate the visual acceptability of this new lens design. Methods: In a double‐masked, randomized, crossover trial, 24 subjects (aged 18 to 25 years) wore MiSight contact lenses and Proclear Multifocal +2.00 diopters Add D (MF) soft contact lenses. Patient‐reported outcomes (0 to 100 scale) and objective measures of visual performance were acquired for best‐spectacle distance correction (BC) and with each contact lens after 1 week of daily use at HIHC (high illumination–high contrast) at distance and LILC (low illumination–low contrast) at distance, intermediate, and near. Results: There were no significant differences in HIHC distance acuity between BC and either the DF or MF lens and no difference between the DF and MF lenses. However, when measured under LILC, there were significant mean differences between each study lens and BC viewed at distance and intermediate. The LILC logMAR visual acuity was not significantly different between the DF and MF lenses at any viewing distance. Although average visual quality and ghosting ratings for both DF and MF study lenses were significantly lower than habitual under all conditions, there were no significant differences between the DF and MF lenses (p = 0.448). Conclusions: Good acuity, similar to that attainable with typical MF lens correction, is attainable with a new contact lens designed to control myopia progression. However, like other contact lenses that contain multiple refractive zones, some decrease in visual performance may be experienced.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Adaptation appears faster, and patient satisfaction is higher with FFLs”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [56]
Citations
Cites
Increased Prevalence of Myopia in the United States Between 1971-1972 and 1999-2004
Vitale, S. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.303 · Cited by 906
Effect of Dual-Focus Soft Contact Lens Wear on Axial Myopia Progression in Children
Anstice, N. S., & Phillips, J. R. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.10.035 · Cited by 422
Sankaridurg, P., Holden, B., Smith, E., Naduvilath, T., Chen, X., de la Jara, P. L., Martinez, A., Kwan, J., Ho, A., Frick, K., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7260 · Cited by 394
Low-Contrast Letter Charts as a Test of Visual Function
Regan, D., & Neima, D. (1983) · Ophthalmology · doi:10.1016/s0161-6420(83)34407-9 · Cited by 210
Dayan, Y. B., Levin, A., Morad, Y., Grotto, I., Ben-David, R., Goldberg, A., Onn, E., Avni, I., Levi, Y., & Benyamini, O. G. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0260 · Cited by 200
A Randomized Trial of the Effects of Rigid Contact Lenses on MyopiaProgression
Walline, J. J. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.12.1760 · Cited by 185
Refractive Error, Axial Dimensions, and Primary Open-Angle Glaucoma: The Singapore Malay Eye Study
Perera, S. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.125 · Cited by 182
Progression of Myopia in Hong Kong Chinese Schoolchildren Is Slowed by Wearing Progressive Lenses
Leung, J., & Brown, B. H. (1999) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1999.tb05413.x · Cited by 179
Comparison of the effect of atropine and cyclopentolate on myopia.
Yen, M., Liu, J., Kao, S.-C., et al. (1989) · PubMed · Cited by 179
Rose, K. (2000) · British Journal of Ophthalmology · doi:10.1136/bjo.84.9.1031 · Cited by 172
Research works printed but not linked: 4
- Douthwaite W, 2006, Contact Lens Optics and Lens Design
- Winer BL, 1971, Statistical Principles in Experimental Design
- Sawides L, 2011, Adapting to blur produced by ocular high‐order aberrations, J Vis, 11, 21, 10.1167/11.7.21 · DOI
- Sheedy JE, 1993, Does the presbyopic visual system adapt to contact lenses?, Optom Vis Sci, 70, 482, 10.1097/00006324-199306000-00006 · doi:10.1097/00006324-199306000-00006
Cited by
IMI Prevention of Myopia and Its Progression
Jonas, J. B., Ang, M., Cho, P., Guggenheim, J. A., He, M. G., Jong, M., Logan, N. S., Liu, M., Morgan, I., Ohno-Matsui, K., et al. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.5.6 · Cited by 475
Myopic maculopathy: Current status and proposal for a new classification and grading system (ATN)
Ruiz-Medrano, J., Montero, J. A., Flores-Moreno, I., Arias, L., García-Layana, A., & Ruiz-Moreno, J. M. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.10.005 · Cited by 446
Ladopoulos, K., Pateras, E., & Ninos, G. (2026) · Cureus · doi:10.7759/cureus.104008
“The FFLs are associated with shorter adaptation time, especially in first-time PAL wearers and those switching from a simpler design, and a greater frequency of immediately comfortable vision [54-56].”
Metadata
- Authors
- Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E.
- Affiliations
- Indiana University Bloomington (US)
- Sydney New South Wales Australia
- Corresponding author
- Kollbaum, Pete S.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-03
- Volume
- 90
- Issue
- 3
- Pages
- 205-214
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2002038873
- Cited by
- 109
- References
- 37
- Citations by year
- 2026: 9 · 2025: 9 · 2024: 8 · 2023: 10 · 2022: 12 · 2021: 13 · 2020: 8 · 2019: 10 · 2018: 9 · 2017: 4 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 3
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Optometry and Vision Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- CooperVision
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- myopia control, visual performance, visual quality, ghosting, intermediate and near vision, patient-reported outcomes
- MeSH terms
- Adult, Contact Lenses, Hydrophilic, Double-Blind Method, Equipment Design, Female, Follow-Up Studies, Humans, Male, Myopia, Refraction, Ocular, Visual Acuity, Disease Progression, Cross-Over Studies, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vision Performance With a Contact Lens Designed to Slow Myopia Progression. https://app.cochat.ai/papers/10.1097/opx.0b013e3182812205
- The paper
- Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E. (2013). Vision Performance With a Contact Lens Designed to Slow Myopia Progression. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e3182812205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.