CoChat

Vision Performance With a Contact Lens Designed to Slow Myopia Progression

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Purpose: Recent research suggests multizone/dual‐focus (DF) lens corrections may aid in controlling the progression of myopia. Recently, such a soft contact lens has become commercially available in Hong Kong (MiSight, CooperVision). The purpose of the current study was to evaluate the visual acceptability of this new lens design. Methods: In a double‐masked, randomized, crossover trial, 24 subjects (aged 18 to 25 years) wore MiSight contact lenses and Proclear Multifocal +2.00 diopters Add D (MF) soft contact lenses. Patient‐reported outcomes (0 to 100 scale) and objective measures of visual performance were acquired for best‐spectacle distance correction (BC) and with each contact lens after 1 week of daily use at HIHC (high illumination–high contrast) at distance and LILC (low illumination–low contrast) at distance, intermediate, and near. Results: There were no significant differences in HIHC distance acuity between BC and either the DF or MF lens and no difference between the DF and MF lenses. However, when measured under LILC, there were significant mean differences between each study lens and BC viewed at distance and intermediate. The LILC logMAR visual acuity was not significantly different between the DF and MF lenses at any viewing distance. Although average visual quality and ghosting ratings for both DF and MF study lenses were significantly lower than habitual under all conditions, there were no significant differences between the DF and MF lenses (p = 0.448). Conclusions: Good acuity, similar to that attainable with typical MF lens correction, is attainable with a new contact lens designed to control myopia progression. However, like other contact lenses that contain multiple refractive zones, some decrease in visual performance may be experienced.

Overview

Integrity signals

Registry

Crossref · 10.1097/opx.0b013e3182812205

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 37 references

Research works printed but not linked: 4

  1. Douthwaite W, 2006, Contact Lens Optics and Lens Design
  2. Winer BL, 1971, Statistical Principles in Experimental Design
  3. Sawides L, 2011, Adapting to blur produced by ocular high‐order aberrations, J Vis, 11, 21, 10.1167/11.7.21 · DOI
  4. Sheedy JE, 1993, Does the presbyopic visual system adapt to contact lenses?, Optom Vis Sci, 70, 482, 10.1097/00006324-199306000-00006 · doi:10.1097/00006324-199306000-00006

Cited by

See all 109

Metadata

Authors
Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E.
Affiliations
  • Indiana University Bloomington (US)
  • Sydney New South Wales Australia
Corresponding author
Kollbaum, Pete S.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2013-03
Volume
90
Issue
3
Pages
205-214
ISSN
  • 1040-5488 (ISSN-L)
  • 1538-9235
OpenAlex
W2002038873
Cited by
109
References
37
Citations by year
2026: 9 · 2025: 9 · 2024: 8 · 2023: 10 · 2022: 12 · 2021: 13 · 2020: 8 · 2019: 10 · 2018: 9 · 2017: 4 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 3
FWCI
3.88
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Optometry and Vision Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
CooperVision
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
  • Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
Keywords
myopia control, visual performance, visual quality, ghosting, intermediate and near vision, patient-reported outcomes
MeSH terms
Adult, Contact Lenses, Hydrophilic, Double-Blind Method, Equipment Design, Female, Follow-Up Studies, Humans, Male, Myopia, Refraction, Ocular, Visual Acuity, Disease Progression, Cross-Over Studies, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vision Performance With a Contact Lens Designed to Slow Myopia Progression. https://app.cochat.ai/papers/10.1097/opx.0b013e3182812205
The paper
Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E. (2013). Vision Performance With a Contact Lens Designed to Slow Myopia Progression. Optometry and Vision Science. https://doi.org/10.1097/opx.0b013e3182812205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.