The DOI matches its Crossref record.
Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Abstract
Microneurosurgical techniques to reconstruct nerve gaps with nerve grafts frequently fail to achieve excellent functional results and create donor-site morbidity. In the present study, 15 patients had gaps of 0.5 to 3.0 cm (mean 1.7 cm) in digital nerves reconstructed by one surgeon with a bioabsorbable polyglycolic acid (PGA) tube. A final evaluation of sensibility was done by a second surgeon at a mean postoperative interval of 22.4 months (range 11 to 32 months). These were all secondary reconstructions. The evaluation included a digital nerve block with local anesthetic for the intact (not reconstructed) digital nerve. Excellent functional sensation (moving two-point discrimination less than or equal to 3 mm and/or static two-point discrimination less than or equal to 6 mm) was present in 33 percent and good functional sensation (moving two-point discrimination of 4 to 7 mm and/or static two-point discrimination of 7 to 15 mm) in 53 percent of the digital nerve reconstructions. One patient with poor sensory recovery and one with no recovery were judged as functional failures (14 percent). Absence of pain at the site of reconstruction was judged by the patient to be excellent in 40 percent, good in 33 percent, and poor in 27 percent. We conclude that reconstruction of nerve gaps of up to 3.0 cm with a bioabsorbable PGA tube gives clinical results at least comparable to the classic nerve graft technique while avoiding donor-site morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
Biocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Sundback, C. A., Shyu, J. Y., Wang, Y., Faquin, W. C., Langer, R. S., Vacanti, J. P., & Hadlock, T. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.004 · Cited by 443
Monkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359
Nerve conduits for nerve repair or reconstruction
Deal, N. D., Griffin, J. W., & Hogan, M. V. (2012) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-20-02-063 · Cited by 126
Metadata
- Authors
- Mackinnon, S. E., & Dellon, A. L.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1990-03
- Volume
- 85
- Issue
- 3
- Pages
- 419-424
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1997905786
- Cited by
- 535
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube. https://app.cochat.ai/papers/10.1097/00006534-199003000-00015
- The paper
- Mackinnon, S. E., & Dellon, A. L. (1990). Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199003000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.