Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
The DOI matches its Crossref record.
Abstract
Microneurosurgical techniques to reconstruct nerve gaps with nerve grafts frequently fail to achieve excellent functional results and create donor-site morbidity. In the present study, 15 patients had gaps of 0.5 to 3.0 cm (mean 1.7 cm) in digital nerves reconstructed by one surgeon with a bioabsorbable polyglycolic acid (PGA) tube. A final evaluation of sensibility was done by a second surgeon at a mean postoperative interval of 22.4 months (range 11 to 32 months). These were all secondary reconstructions. The evaluation included a digital nerve block with local anesthetic for the intact (not reconstructed) digital nerve. Excellent functional sensation (moving two-point discrimination less than or equal to 3 mm and/or static two-point discrimination less than or equal to 6 mm) was present in 33 percent and good functional sensation (moving two-point discrimination of 4 to 7 mm and/or static two-point discrimination of 7 to 15 mm) in 53 percent of the digital nerve reconstructions. One patient with poor sensory recovery and one with no recovery were judged as functional failures (14 percent). Absence of pain at the site of reconstruction was judged by the patient to be excellent in 40 percent, good in 33 percent, and poor in 27 percent. We conclude that reconstruction of nerve gaps of up to 3.0 cm with a bioabsorbable PGA tube gives clinical results at least comparable to the classic nerve graft technique while avoiding donor-site morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Lundborg, G. (2000) · The Journal of Hand Surgery · doi:10.1053/jhsu.2000.4165 · Cited by 656
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
“[45,88,89], centrifugal casting [90], spinning mandrel technology [91], film casting plus rolling [92,93], and molding plus freeze-”
MethodWeber, R. A., Breidenbach, W. C., Brown, R. E., Jabaley, M. E., & Mass, D. P. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200010000-00013 · Cited by 552
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Chapter 8 Current Techniques and Concepts in Peripheral Nerve Repair
Siemionow, M., & Brzezicki, G. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)87008-6 · Cited by 453
Biocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Sundback, C. A., Shyu, J. Y., Wang, Y., Faquin, W. C., Langer, R. S., Vacanti, J. P., & Hadlock, T. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.004 · Cited by 443
Peripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 415
A Polymer Foam Conduit Seeded with Schwann Cells Promotes Guided Peripheral Nerve Regeneration
Hadlock, T., Sundback, C., Hunter, D., Cheney, M., & Vacanti, J. P. (2000) · Tissue Engineering · doi:10.1089/107632700320748 · Cited by 404
Biomaterials for the Development of Peripheral Nerve Guidance Conduits
Nectow, A. R., Marra, K. G., & Kaplan, D. L. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0240 · Cited by 395
Controlled release of nerve growth factor enhances sciatic nerve regeneration
Lee, A. C., Yu, V. M., Lowe, J. B., Brenner, M. J., Hunter, D. A., Mackinnon, S. E., & Sakiyama-Elbert, S. E. (2003) · Experimental Neurology · doi:10.1016/s0014-4886(03)00258-9 · Cited by 369
Self-citationMonkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359
Pfister, B. J., Gordon, T., Loverde, J. R., Kochar, A. S., Mackinnon, S. E., & Cullen, D. K. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i2.20 · Cited by 358
Self-citationBattiston, B., Geuna, S., Ferrero, M., & Tos, P. (2005) · Microsurgery · doi:10.1002/micr.20127 · Cited by 346
Peripheral Nerve Repair and Reconstruction
Griffin, J. W., Hogan, M. V., Chhabra, A. B., & Deal, D. N. (2013) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.l.00704 · Cited by 310
Meek, M. F., & Coert, J. H. (2008) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e31804d441c · Cited by 271
Nerve Repair by Means of Tubulization: Past, Present, Future
Konofaos, P., & Ver Halen, J. (2013) · Journal of Reconstructive Microsurgery · doi:10.1055/s-0032-1333316 · Cited by 269
Limitations of Conduits in Peripheral Nerve Repairs
Moore, A. M., Kasukurthi, R., Magill, C. K., Farhadi, H. F., Borschel, G. H., & Mackinnon, S. E. (2009) · HAND · doi:10.1007/s11552-008-9158-3 · Cited by 268
Self-citationSynthetic Nerve Guide Implants in Humans: A Comprehensive Survey
Schlosshauer, B., Dreesmann, L., Schaller, H.-E., & Sinis, N. (2006) · Neurosurgery · doi:10.1227/01.neu.0000235197.36789.42 · Cited by 245
“Mackinnon and Dellon, 1990 (30) 15 Ø 30 Digital nerves PGA 5-30 11–32”
MethodKarabekmez, F. E., Duymaz, A., & Moran, S. L. (2009) · HAND · doi:10.1007/s11552-009-9195-6 · Cited by 243
“The results of this study have shown nerve recovery which is comparable to previous reports of primary nerve repair as well as nerve repair with conduits [1, 3, 4, 7, 17, 30].”
Bertleff, M. J. O. E., Meek, M. F., & Nicolai, J.-P. A. (2005) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.12.009 · Cited by 233
Adhesive and mechanical properties of hydrogels influence neurite extension
Gunn, J. W., Turner, S. D., & Mann, B. K. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30203 · Cited by 230
Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
An, Y. H., Woolf, S. K., & Friedman, R. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00132-0 · Cited by 224
“For nerve regeneration, several materials, such as PGA tubes [110,111], PLA/PCL conduits [112], and other forms of absorbable guides [113] have been investigated with controversial results.”
BackgroundIchihara, S., Inada, Y., & Nakamura, T. (2008) · Injury · doi:10.1016/j.injury.2008.08.029 · Cited by 222
Surface modified electrospun nanofibrous scaffolds for nerve tissue engineering
Prabhakaran, M. P., Venugopal, J., Chan, C. K., & Ramakrishna, S. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/45/455102 · Cited by 222
Cooper, M. L., Hansbrough, J. F., Spielvogel, R. L., Cohen, R., Bartel, R. L., & Naughton, G. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90207-q · Cited by 221
The development of bioartificial nerve grafts for peripheral-nerve regeneration
Heath, C. A., & Rutkowski, G. E. (1998) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01165-7 · Cited by 217
Growth factor enhancement of peripheral nerve regeneration through a novel synthetic hydrogel tube
Midha, R., Munro, C. A., Dalton, P. D., Tator, C. H., & Shoichet, M. S. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.3.0555 · Cited by 207
Bioengineered Strategies for Spinal Cord Repair
Nomura, H., Tator, C. H., & Shoichet, M. S. (2006) · Journal of Neurotrauma · doi:10.1089/neu.2006.23.496 · Cited by 206
“Also, PGA tubes have been successfully used as guidance channels for axonal reconnection in human PNS injury (Mackinnon and Dellon, 1990).”
Poly-3-hydroxybutyrate (PHB): a resorbable conduit for long-gap repair in peripheral nerves
Young, R. C., Terenghi, G., & Wiberg, M. (2002) · British Journal of Plastic Surgery · doi:10.1054/bjps.2002.3798 · Cited by 204
Peripheral nerve regeneration within an asymmetrically porous PLGA/Pluronic F127 nerve guide conduit
Oh, S. H., Kim, J. H., Song, K. S., Jeon, B. H., Yoon, J. H., Seo, T. B., Namgung, U., Lee, I. W., & Lee, J. H. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.036 · Cited by 202
Lundborg, G., Rosén, B., Dahlin, L., Danielsen, N., & Holmberg, J. (1997) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80188-1 · Cited by 202
Fiber templating of poly(2-hydroxyethyl methacrylate) for neural tissue engineering
Flynn, L. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00334-x · Cited by 189
“Of the numerous entubulation studies reported to date, some of the best results have been achieved in the PNS over short distances with nerve guides consisting of poly(glycolic acid) [5], poly(caprolactone-co-lactic acid) [6] and collagen [7].”
Background3D Printed Personalized Nerve Guide Conduits for Precision Repair of Peripheral Nerve Defects
Liu, K., Yan, L., Li, R., Song, Z., Ding, J., Liu, B., & Chen, X. (2022) · Advanced Science · doi:10.1002/advs.202103875 · Cited by 183
Transplanted neuronal progenitor cells in a peripheral nerve gap promote nerve repair
Murakami, T., Fujimoto, Y., Yasunaga, Y., Ishida, O., Tanaka, N., Ikuta, Y., & Ochi, M. (2003) · Brain Research · doi:10.1016/s0006-8993(03)02539-3 · Cited by 182
Tsai, E. C., Dalton, P. D., Shoichet, M. S., & Tator, C. H. (2004) · Journal of Neurotrauma · doi:10.1089/0897715041269687 · Cited by 180
“…Teng et al., 2002; Xu et al., 1995; Xu et al., 1999) have pursued an entubulation strategy to promote axonal regeneration in the completely transected spinal cord, similar to the strategy used for peripheral nerve repair (Fields et al., 1989; Lundborg et al., 1981; Mackinnon and Dellon, 1990).”
MethodThe peripheral nerve allograft: A comprehensive review of regeneration and neuroimmunology
Evans, P. J., Midha, R., & Mackinnon, S. E. (1994) · Progress in Neurobiology · doi:10.1016/0301-0082(94)90001-9 · Cited by 180
Self-citationMadigan, N. N., McMahon, S., O’Brien, T., Yaszemski, M. J., & Windebank, A. J. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.08.015 · Cited by 178
The Role of Conduits in Nerve Repair: A Review
Doolabh, V. B., Hertl, M. C., & Mackinnon, S. E. (1996) · Reviews in the Neurosciences · doi:10.1515/revneuro.1996.7.1.47 · Cited by 177
Self-citationScaffolds for peripheral nerve repair and reconstruction
Yi, S., Xu, L., & Gu, X. (2019) · Experimental Neurology · doi:10.1016/j.expneurol.2018.05.016 · Cited by 172
Krarup, C., Archibald, S. J., & Madison, R. D. (2002) · Annals of Neurology · doi:10.1002/ana.10054 · Cited by 172
Carbon nanotubes leading the way forward in new generation 3D tissue engineering
Hopley, E. L., Salmasi, S., Kalaskar, D. M., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.05.003 · Cited by 166
Nakamura, T., Inada, Y., Fukuda, S., Yoshitani, M., Nakada, A., Itoi, S.-I., Kanemaru, S.-I., Endo, K., & Shimizu, Y. (2004) · Brain Research · doi:10.1016/j.brainres.2004.08.040 · Cited by 165
Xie, J., MacEwan, M. R., Liu, W., Jesuraj, N., Li, X., Hunter, D., & Xia, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5018557 · Cited by 162
Tissue Engineering and Regenerative Medicine
Salgado, A. J., Oliveira, J. M., Martins, A., Teixeira, F. G., Silva, N. A., Neves, N. M., Sousa, N., & Reis, R. L. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-410499-0.00001-0 · Cited by 162
Collagen Tube Conduits in Peripheral Nerve Repair: A Retrospective Analysis
Wangensteen, K. J., & Kalliainen, L. K. (2010) · HAND · doi:10.1007/s11552-009-9245-0 · Cited by 161
“A number of studies suggest that bioabsorbable nerve conduits are at least as effective as nerve grafting for repair of short nerve defects, without the morbidity associated with graft harvest [2, 3, 10–12].”
BackgroundBiomimetic Architectures for Peripheral Nerve Repair: A Review of Biofabrication Strategies
Wieringa, P. A., Gonçalves de Pinho, A. R., Micera, S., van Wezel, R. J. A., & Moroni, L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701164 · Cited by 160
Bridging nerve defects with combined skeletal muscle and vein conduits
Brunelli, G. A., Battiston, B., Vigasio, A., Brunelli, G., & Marocolo, D. (1993) · Microsurgery · doi:10.1002/micr.1920140407 · Cited by 160
Nerve conduits for nerve repair or reconstruction
Deal, N. D., Griffin, J. W., & Hogan, M. V. (2012) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-20-02-063 · Cited by 126
Metadata
- Authors
- Mackinnon, S. E., & Dellon, A. L.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1990-03
- Volume
- 85
- Issue
- 3
- Pages
- 419-424
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1997905786
- Cited by
- 535
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.