Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 448

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

The Use of Autologous Platelet-Rich Plasma (Platelet Gel) and Autologous Platelet-Poor Plasma (Fibrin Glue) in Cosmetic Surgery

Man, Daniel, Plosker, Harvey, Winland-Brown, Jill E.·2001·Plastic and Reconstructive Surgery

Abstract

The purpose of this study was to evaluate a new technique of harvesting and preparing autologous platelet gel and autologous fibrin glue (body glue) and to evaluate their effectiveness in stopping capillary bleeding in the surgical flaps of patients undergoing cosmetic surgery. A convenience sample of 20 patients ranging from 25 to 76 years of age undergoing cosmetic surgery involving the creation of a surgical flap were included in the study. The types of surgical procedures included face lifts, breast augmentations, breast reductions, and neck lifts. Platelet-poor and platelet-rich plasma were prepared during the procedure from autologous blood using a compact, tabletop, automated autologous platelet concentrate system (SmartPReP, Harvest Autologous Hemobiologics, Norwell, Mass.). The platelet-poor and platelet-rich plasma were combined with a thrombin-calcium chloride solution to produce autologous fibrin glue and autologous platelet gel, respectively. Capillary bed bleeding was present in all cases and effectively sealed within 3 minutes following the application of platelet gel and fibrin glue. The technique for making the solution and for evaluating its effectiveness in achieving and maintaining hemostasis during cosmetic surgical procedures is described. Autologous platelet gel and fibrin glue prepared by the automated concentrate system are compared with autotransfusor-prepared platelet gel and Tisseel (Baxter Healthcare Corp.), a commercially prepared fibrin sealant preparation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006534-200101000-00037

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 448

Metadata

Authors
Man, D., Plosker, H., & Winland-Brown, J. E.
Venue
Plastic and Reconstructive Surgery
Published
2001-01
Volume
107
Issue
1
Pages
229-236
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2109124138
Cited by
448
References
7
FWCI
10.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Use of Autologous Platelet-Rich Plasma (Platelet Gel) and Autologous Platelet-Poor Plasma (Fibrin Glue) in Cosmetic Surgery. https://app.cochat.ai/papers/10.1097/00006534-200101000-00037
The paper
Man, D., Plosker, H., & Winland-Brown, J. E. (2001). The Use of Autologous Platelet-Rich Plasma (Platelet Gel) and Autologous Platelet-Poor Plasma (Fibrin Glue) in Cosmetic Surgery. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-200101000-00037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.