Dermal Substitution in Acute Burns and Reconstructive Surgery: A Subjective and Objective Long-Term Follow-Up
The DOI matches its Crossref record.
Abstract
Tissue engineering and dermal substitution are currently prominent topics of wound-healing research. However, no extensive clinical trials with objective evaluation criteria have been published so far that support the clinical effectiveness of dermal equivalents in the long term. The dermal substitute that is discussed here is derived from bovine collagen and elastin-hydrolysate and has been shown to improve skin elasticity during a short-term clinical follow-up of scar reconstructions. In this study we will present the long-term outcome by means of objective and subjective scar assessment tools for dermal substitution in acute burn wounds and scar reconstructions. In a clinical trial, an intraindividual comparison was performed between the conventional split-thickness autograft and a combination of the collagen/elastin substitute with an autograft. After 1 year, scars were evaluated by the Cutometer SEM 474 for objective elasticity measurements and by planimetry to establish scar contraction. An independent observer subjected scars to a generally accepted clinical scar assessment tool: the Vancouver Scar Scale. In addition, patients gave their impression of the outcome. Forty-two paired burn wounds and 44 paired scar reconstructions were included and evaluated 1 year after surgery. Although substituted scar reconstructions demonstrated an elasticity improvement of approximately 20 percent compared with control wounds, no statistically significant differences were found for skin elasticity, scar contraction, Vancouver Scar Scale, and patient's impression in both categories after 1 year. An extensive long-term follow-up shows that the dermal substitute, which was proven effective in a clinical trial on a short-term basis, did not yield statistical evidence for a long-term clinical effectiveness of dermal substitution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Patient and Observer Scar Assessment Scale: A Reliable and Feasible Tool for Scar Evaluation
Draaijers, L. J., Tempelman, F. R. H., Botman, Y. A. M., Tuinebreijer, W. E., Middelkoop, E., Kreis, R. W., & van Zuijlen, P. P. M. (2004) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000122207.28773.56 · Cited by 1,275
Self-citationElastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Elastin as a biomaterial for tissue engineering
Daamen, W. F., Veerkamp, J. H., van Hest, J. C. M., & van Kuppevelt, T. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.025 · Cited by 518
Hypertrophic Scar Formation Following Burns and Trauma: New Approaches to Treatment
Aarabi, S., Longaker, M. T., & Gurtner, G. C. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040234 · Cited by 314
Prevention and curative management of hypertrophic scar formation
Bloemen, M. C. T., van der Veer, W. M., Ulrich, M. M. W., van Zuijlen, P. P. M., Niessen, F. B., & Middelkoop, E. (2009) · Burns · doi:10.1016/j.burns.2008.07.016 · Cited by 272
Self-citationAlmine, J. F., Bax, D. V., Mithieux, S. M., Nivison-Smith, L., Rnjak, J., Waterhouse, A., Wise, S. G., & Weiss, A. S. (2010) · Chemical Society Reviews · doi:10.1039/b919452p · Cited by 256
Biological Background of Dermal Substitutes
van der Veen, V. C., van der Wal, M. B. A., van Leeuwen, M. C. E., Ulrich, M. M. W., & Middelkoop, E. (2010) · Burns · doi:10.1016/j.burns.2009.07.012 · Cited by 222
Self-citationA systematic review of the quality of burn scar rating scales for clinical and research use
Tyack, Z., Simons, M., Spinks, A., & Wasiak, J. (2012) · Burns · doi:10.1016/j.burns.2011.09.021 · Cited by 217
“Fifty-four studies were excluded because they did not provide data on relevant outcomes [2,4,30–74], were a mixture of narrative or systematic reviews, guidelines, commentaries and other descriptive articles [1,6,17,76–78],”
BackgroundJeschke, M. G., Wood, F. M., Middelkoop, E., Bayat, A., Teot, L., Ogawa, R., & Gauglitz, G. G. (2023) · Nature Reviews Disease Primers · doi:10.1038/s41572-023-00474-x · Cited by 217
“A cutometer, a hand-held spring pressure sensor, may be used when diagnosing scars 98 for scar elasticity characteristics or colorimetric measurements for redness and pigmentation.”
MethodSelf-citationDiversity of Fibroblasts – A Review on Implications for Skin Tissue Engineering
Nolte, S. V., Xu, W., Rennekampff, H.-O., & Rodemann, H. P. (2008) · Cells Tissues Organs · doi:10.1159/000111805 · Cited by 166
“Rudolph, R., J. Vande Berg, G.F. Pierce (1991) Changing concept in myofibroblast function and control; in Janssen, H., J.I.S. Rooman (eds): Wound Healing.”
BackgroundInfluentialA systematic review of objective burn scar measurements
Lee, K. C., Dretzke, J., Grover, L., Logan, A., & Moiemen, N. (2016) · Burns & Trauma · doi:10.1186/s41038-016-0036-x · Cited by 165
Objective Assessment of Burn Scar Vascularity, Erythema, Pliability, Thickness, and Planimetry
Oliveira, G. V., Chinkes, D., Mitchell, C., Oliveras, G., Hawkins, H. K., & Herndon, D. N. (2006) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2005.31004 · Cited by 164
“Scanning reflectance spectrophotometers are expensive and not portable, but the chromameters and dermaspectrometers are less expensive, handheld, and popular.(17,18) Minolta Chromameter CR 200 is illuminated by a lamp, and the white light reflected perpendicular to the surface is collected for a tristimulus color anal…”
BackgroundMethodResultInfluentialEffect of pore size and cross-linking of a novel collagen-elastin dermal substitute on wound healing
Boekema, B. K. H. L., Vlig, M., Olde Damink, L., Middelkoop, E., Eummelen, L., Bühren, A. V., & Ulrich, M. M. W. (2014) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-013-5075-2 · Cited by 77
Self-citationLevinson, H. (2013) · Advances in Wound Care · doi:10.1089/wound.2012.0389 · Cited by 30
“In 2011, Middelkoop’s group reported the first subjective and objective results of a 12-year follow-up of dermal substitution in acute and reconstructive burn wounds, examining their acellular double-layered skin construct.(91) They concluded that, after this long period, there was an improvement in scar parameters in…”
Background
Metadata
- Authors
- van Zuijlen, P. P. M., Vloemans, J. F. P. M., van Trier, A. J. M., Suijker, M. H., van Unen, E., Groenevelt, F., Kreis, R. W., & Middelkoop, E.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2001-12
- Volume
- 108
- Issue
- 7
- Pages
- 1938-1946
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2047155124
- Cited by
- 125
- References
- 0
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.