CoChat

Infrared ear thermometry

NOBEL, JOEL J. · 1992 · Pediatric Emergency Care

The DOI matches its Crossref record.

Abstract

Many hospitals are considering using infrared (IR) ear thermometers (also called tympanic membrane thermometers) as an alternative to traditional temperature-measurement devices. IR technology allows users to quickly and noninvasively measure body temperature by inserting a directional probe into the ear canal. For infection control, ear thermometers offer the advantages of not contacting mucous membranes and eliminating the need for special handling procedures. For use on unconscious patients or those who are otherwise unwilling or unable to cooperate with traditional techniques, IR ear thermometers offer a more comfortable and less stressful method of temperature taking for both patients and nurses, especially where rectal temperatures are used. The recent entry into this market by major companies and distributors and the release of several new IR ear thermometers have helped to further stimulate interest in this technology. However, a complete transition to IR ear thermometers throughout the hospital may not be necessary and should be made only after these devices have been successfully used in selected clinical locations, such as emergency departments, critical care areas, recovery areas, and labor and delivery rooms. Clinical users must be familiar with the technique needed for temperature measurement with these instruments and understand the differences between temperatures taken in the ear canal and those obtained from traditional sites. In the following article, we first present an overview of clinical thermometry, describing traditional temperature-measurement sites and devices. We then discuss the advantages and disadvantages of using the ear canal, including the tympanic membrane (TM), as a site for temperature measurement. In addition, we guide readers in determining the usefulness of IR ear thermometers.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

Integrity signals

Registry

Crossref · 10.1097/00006565-199202000-00016

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 28

Metadata

Authors
NOBEL, J. J.
Corresponding author
NOBEL, JOEL J.
Venue
Pediatric Emergency Care
Published
1992-02
Volume
8
Issue
1
Pages
54-58
ISSN
0749-5161 (ISSN-L)
OpenAlex
W2031622910
Cited by
27
References
0
Citations by year
2019: 1 · 2012: 1
FWCI
2.56
Type
journal article
Language
en
Open access
closed
Locations
  • Pediatric Emergency Care (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Thermal Regulation in Medicine
  • Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
Keywords
body temperature measurement, tympanic membrane, infection control, non-invasive temperature measurement, emergency department, intensive care, labor and delivery
MeSH terms
Humans, Infrared Rays, Thermometers, Tympanic Membrane

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infrared ear thermometry. https://app.cochat.ai/papers/10.1097/00006565-199202000-00016
The paper
NOBEL, J. J. (1992). Infrared ear thermometry. Pediatric Emergency Care. https://doi.org/10.1097/00006565-199202000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.