CoChat

Evaluation of Self-Collected Samples in Contrast to Practitioner-Collected Samples for Detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis by Polymerase Chain Reaction Among Women Living in Remote Areas

KNOX, JANET, TABRIZI, SEPEHR N., MILLER, PENNY, PETOUMENOS, KATHY, LAW, MATHEW, CHEN, SHUJUN, GARLAND, SUZANNE M. · 2002 · Sexually Transmitted Diseases
Cited by 130

The DOI matches its Crossref record.

Abstract

BACKGROUND: Self-collected samples have been shown to be an acceptable and sensitive method for the detection by polymerase chain reaction (PCR) of sexually transmitted infections (STIs) among women. GOAL The goal of the study was to compare self-collected sampling methods to conventional practitioner endocervical sampling for the PCR detection of Chlamydia trachomatis and Neisseria gonorrhoeae to compare two self-collected sampling methods for the detection of T vaginalis by PCR. STUDY DESIGN: Women (n = 318) from urban and remote areas of central Australia participated in the study when attending their health clinic for a check-up. They each provided a FVU sample, self-collected vaginal swab specimen, and tampon specimen. This was followed by a clinical examination by a practitioner, with collection of endocervical and high vaginal swabs for testing by conventional microscopy and culture for N gonorrhoeae and T vaginalis, respectively. The FVU, self-collected vaginal swab, tampon, and endocervical swab specimens were tested by Roche Cobas Amplicor for C trachomatis and N gonorrhoeae. The self-collected vaginal swab and tampon specimens were also tested by an in-house PCR method for the detection of T vaginalis. RESULTS: In toto, C trachomatis was detected by PCR in 11.5%, N gonorrhoeae in 11.8%, and T vaginalis in 24.6%. Molecular diagnostics for N gonorrhoeae and T vaginalis were significantly more sensitive than traditional assays with microscopy and culture. For the detection of C trachomatis by PCR, tampons were the most sensitive (100.0%) and urine the least sensitive (72.7%) specimens ( = 0.01). For the detection of by PCR, the self-collected tampon was the most sensitive specimen, followed by the endocervical swab, self-collected swab, and urine specimen, with sensitivities of 97.2%, 92.6%, 71.9%, and 31.2%, respectively. For detection of N gonorrhoeae, statistically significant differences were detected for urine versus tampon ( < 0.0001), endocervical swab ( < 0.001), and self-collected swab ( = 0.01) and for self-collected swab versus tampon ( = 0.01). Subsequent data collection showed that sensitivity of urine PCR for detection of N gonorrhoeae improved with freezing of urine specimens and shorter transport time. Tampons were also more sensitive than self-collected swabs for detection of T vaginalis (sensitivity of 100% versus 87.7%). CONCLUSION: Self-collected specimens offer women in remote communities an acceptable and sensitive alternative method of testing for STIs. The low sensitivity of N gonorrhoeae PCR of urine specimens may reflect poor transport and storage conditions, which we have shown can be improved by freezing urine specimens and reducing transport delays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007435-200211000-00006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 130

Metadata

Authors
KNOX, J., TABRIZI, S. N., MILLER, P., PETOUMENOS, K., LAW, M., CHEN, S., & GARLAND, S. M.
Venue
Sexually Transmitted Diseases
Published
2002-11
Volume
29
Issue
11
Pages
647-654
ISSN
0148-5717 (ISSN-L)
OpenAlex
W2056287204
Cited by
130
References
0
FWCI
3.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Self-Collected Samples in Contrast to Practitioner-Collected Samples for Detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis by Polymerase Chain Reaction Among Women Living in Remote Areas. https://app.cochat.ai/papers/10.1097/00007435-200211000-00006
The paper
KNOX, J., TABRIZI, S. N., MILLER, P., PETOUMENOS, K., LAW, M., CHEN, S., & GARLAND, S. M. (2002). Evaluation of Self-Collected Samples in Contrast to Practitioner-Collected Samples for Detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis by Polymerase Chain Reaction Among Women Living in Remote Areas. Sexually Transmitted Diseases. https://doi.org/10.1097/00007435-200211000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.