A Biomechanical Study of Odontoid Fractures and Fracture Fixation
The DOI matches its Crossref record.
Abstract
The purpose of this study was to measure the stability of the odontoid process after fracture and subsequent screw fixation. To accomplish this, we mechanically reproduced Type II and Type III odontoid fractures on isolated C2 vertebrae by varying the direction of load. These fractures were subsequently stabilized with a single 3.5 mm screw and retested for multidirectional stability and load to failure. Reduced and instrumented specimens were found to have a stiffness equivalent to one half of that of the unfractured odontoid. Load to failure was also slightly less than one half of the original fracture force (average 160 lb). Screw failure was by a cut-out mechanism in all Type III fractures and by bending of the screw in all Type III fractures. Our findings, in conjunction with the existing literature, strongly suggest that Type III fractures result from extension forces, whereas Type II fractures result from lateral or oblique loading forces. Single screw fixation of an odontoid fracture will provide stability equal to approximately one half that of the unfractured bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Nature of the Principal Type 1 Interferon-Producing Cells in Human Blood
Siegal, F. P., Kadowaki, N., Shodell, M., Fitzgerald-Bocarsly, P. A., Shah, K., Ho, S., Antonenko, S., & Liu, Y.-J. (1999) · Science · doi:10.1126/science.284.5421.1835 · Cited by 2,293
Differentiation of Monocytes into Dendritic Cells in a Model of Transendothelial Trafficking
Randolph, G. J., Beaulieu, S., Lebecque, S., Steinman, R. M., & Muller, W. A. (1998) · Science · doi:10.1126/science.282.5388.480 · Cited by 809
Menezes, A. H., & Traynelis, V. C. (2008) · Child's Nervous System · doi:10.1007/s00381-008-0606-8 · Cited by 186
“[77] studied odontoid screw fixation in a mechanically induced injury model of types II and III odontoid fractures.”
BackgroundNightingale, R. W., Winkelstein, B. A., Knaub, K. E., Richardson, W. J., Luck, J. F., & Myers, B. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00037-4 · Cited by 171
Flexion and extension structural properties and strengths for male cervical spine segments
Nightingale, R. W., Carol Chancey, V., Ottaviano, D., Luck, J. F., Tran, L., Prange, M., & Myers, B. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.015 · Cited by 153
Metadata
- Authors
- Doherty, B. J., Heggeness, M. H., & Esses, S. I.
- Venue
- Spine
- Published
- 1993-02
- Volume
- 18
- Issue
- 2
- Pages
- 178-184
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1994691354
- Cited by
- 96
- References
- 0
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Biomechanical Study of Odontoid Fractures and Fracture Fixation. https://app.cochat.ai/papers/10.1097/00007632-199302000-00002
- The paper
- Doherty, B. J., Heggeness, M. H., & Esses, S. I. (1993). A Biomechanical Study of Odontoid Fractures and Fracture Fixation. Spine. https://doi.org/10.1097/00007632-199302000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.