Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 275

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Prediction of Load Sharing Among Spinal Components of a C5-C6 Motion Segment Using the Finite Element Approach

Goel, Vijay K., Clausen, John D. · 1998 · Spine

Abstract

STUDY DESIGN: A finite element model of the ligamentous cervical spinal segment was used to compute loads in various structures in response to clinically relevant loading modes. OBJECTIVE: To predict biomechanical parameters, including intradisc pressure, tension in ligaments, and forces across facets that are not practical to quantify with an experimental approach. SUMMARY OF BACKGROUND DATA: Finite element models of the cervical spine in their present form, because of inherent assumptions and simplifications, are not entirely satisfactory for studying the biomechanics of the intact, injured, and stabilized cervical spinal segment. METHODS: A three-dimensional finite element model of a C5-C6 motion segment was developed from serial computed tomographic scans of a ligamentous cervical spinal segment. This model included nonlinear ligament definition, fully composite intervertebral disc, fluid nucleus, and Luschka's joints. The model-based displacement predictions were in agreement with the experimental data. This model was used to predict load sharing and other related parameters in spinal elements in response to various loading modalities. RESULTS: In axial compression, 88% of the applied load passed through the disc. The interspinal ligament experienced the most strain (29.5%) in flexion, and the capsular ligaments were strained the most (15.5%) in axial rotation. The maximum intradisc pressure was 0.24 MPa in the flexion with axial compression mode (1.8 Nm + 73.6 N). The anterior and posterior disc bulges increased with the increase in axial compression (up to 800 N). CONCLUSIONS: The results provide new insight into the role of various elements in transmitting loads. The model represents significant and essential advancement in comparison with previous finite element models, making it possible for such models to be used in investigating a broad spectrum of clinically relevant issues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199803150-00008

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 275

Metadata

Authors
Goel, V. K., & Clausen, J. D.
Venue
Spine
Published
1998-03
Volume
23
Issue
6
Pages
684-691
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2326699250
Cited by
275
References
12
FWCI
7.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of Load Sharing Among Spinal Components of a C5-C6 Motion Segment Using the Finite Element Approach. https://app.cochat.ai/papers/10.1097/00007632-199803150-00008
The paper
Goel, V. K., & Clausen, J. D. (1998). Prediction of Load Sharing Among Spinal Components of a C5-C6 Motion Segment Using the Finite Element Approach. Spine. https://doi.org/10.1097/00007632-199803150-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.