The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Criterion Validity of the Cervical Range of Motion (CROM) Goniometer for Cervical Flexion and Extension
Abstract
STUDY DESIGN: This study used a validity protocol. OBJECTIVE: To estimate the criterion validity of the Cervical Range of Motion goniometer using a healthy population. SUMMARY OF BACKGROUND DATA: The results of the 1994 study by Mayo et al show that there are no validated tools currently available for clinically measuring the cervical range of motion. Numerous decisions regarding patient status and treatment are based wholly or in part on joint motion measurements. Because of current budgetary restrictions, clinicians are being asked to justify their interventions objectively, and to do so, they will need validated tools. METHODS: The population consisted of 31 healthy participants ranging in age from 18 to 45 years. None had experienced cervical problems in the previous 3 months or were pregnant. Data collection took place at the radiology department. After participants were positioned on a stool, the cervical range of motion goniometer frame was set on their head by the physiotherapist. With the participant in this neutral position, the physiotherapist took the first Cervical Range of Motion measurement. The radiograph technologist obtained the radiograph immediately afterward. This procedure was repeated with the participant in fully flexed and fully extended positions. RESULTS: A Pearson's r correlation test was used to evaluate the criterion validity of the Cervical Range of Motion goniometer versus the radiographic method. The two measurements proved to be highly correlated (flexion: r = 0.97, P < 0.001; extension: r = 0.98, P < 0.001). CONCLUSIONS: For this population of healthy participants, the Cervical Range of Motion goniometer was found to be valid for measurements of cervical flexion and extension. Further research is needed on the validity of this instrument for other cervical spine movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Fletcher, J. P., & Bandy, W. D. (2008) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2008.2680 · Cited by 304
Dunleavy, K., Neil, J., Tallon, A., & Adamo, D. E. (2015) · Journal of Manual & Manipulative Therapy · doi:10.1179/2042618614y.0000000070 · Cited by 23
Metadata
- Authors
- Tousignant, M., de Bellefeuille, L., O’Donoughue, S., & Grahovac, S.
- Venue
- Spine
- Published
- 2000-02
- Volume
- 25
- Issue
- 3
- Pages
- 324-330
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2038341332
- Cited by
- 166
- References
- 1
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Criterion Validity of the Cervical Range of Motion (CROM) Goniometer for Cervical Flexion and Extension. https://app.cochat.ai/papers/10.1097/00007632-200002010-00011
- The paper
- Tousignant, M., de Bellefeuille, L., O’Donoughue, S., & Grahovac, S. (2000). Criterion Validity of the Cervical Range of Motion (CROM) Goniometer for Cervical Flexion and Extension. Spine. https://doi.org/10.1097/00007632-200002010-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.