Criterion Validity of the Cervical Range of Motion (CROM) Goniometer for Cervical Flexion and Extension
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: This study used a validity protocol. OBJECTIVE: To estimate the criterion validity of the Cervical Range of Motion goniometer using a healthy population. SUMMARY OF BACKGROUND DATA: The results of the 1994 study by Mayo et al show that there are no validated tools currently available for clinically measuring the cervical range of motion. Numerous decisions regarding patient status and treatment are based wholly or in part on joint motion measurements. Because of current budgetary restrictions, clinicians are being asked to justify their interventions objectively, and to do so, they will need validated tools. METHODS: The population consisted of 31 healthy participants ranging in age from 18 to 45 years. None had experienced cervical problems in the previous 3 months or were pregnant. Data collection took place at the radiology department. After participants were positioned on a stool, the cervical range of motion goniometer frame was set on their head by the physiotherapist. With the participant in this neutral position, the physiotherapist took the first Cervical Range of Motion measurement. The radiograph technologist obtained the radiograph immediately afterward. This procedure was repeated with the participant in fully flexed and fully extended positions. RESULTS: A Pearson's r correlation test was used to evaluate the criterion validity of the Cervical Range of Motion goniometer versus the radiographic method. The two measurements proved to be highly correlated (flexion: r = 0.97, P < 0.001; extension: r = 0.98, P < 0.001). CONCLUSIONS: For this population of healthy participants, the Cervical Range of Motion goniometer was found to be valid for measurements of cervical flexion and extension. Further research is needed on the validity of this instrument for other cervical spine movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898 · cited 1×
“The most valid reference measurement, or gold standard, for the spine is the radiographic method.(1,3,7,11,13) For this reason, radiographs were used as the gold standard in this research.”
MethodRelman, A. S. (1988) · New England Journal of Medicine · doi:10.1056/nejm198811033191810 · Cited by 580
Reliability of Measurements of Cervical Spine Range of Motion—Comparison of Three Methods
Youdas, J. W., Carey, J. R., & Garrett, T. R. (1991) · Physical Therapy · doi:10.1093/ptj/71.2.98 · Cited by 514
Normal Range of Motion of the Cervical Spine: An Initial Goniometric Study
Youdas, J. W., Garrett, T. R., Suman, V. J., Bogard, C. L., Hallman, H. O., & Carey, J. R. (1992) · Physical Therapy · doi:10.1093/ptj/72.11.770 · Cited by 404
Conservative therapy for low back pain. Distinguishing useful from useless therapy
Deyo, R. A. (1983) · JAMA · doi:10.1001/jama.250.8.1057 · Cited by 296
Intratester and intertester reliability of the cervical range of motion device.
CAPUANO-PUCCI, D. L., Rheault, W., Aukai, J., Bracke, M., Day, R. G., & Pastrick, M. (1991) · PubMed · Cited by 171
Reliability of Measuring Forward Head Posture in a Clinical Setting
Garrett, T. R., Youdas, J. W., & Madson, T. J. (1993) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1993.17.3.155 · Cited by 111 · cited 1×
“A study was performed in another context to determine the measurement reliability of forward head posture.(8) The researchers demonstrated very good intrarater (ICC 5 0.”
MethodOUTCOMES RESEARCH IN MEDICAL REHABILITATION
Johnston, M. V., & Granger, C. V. (1994) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199407000-00014 · Cited by 44 · cited 2×
“In view of this recommendation, the costs associated with these injuries, and the current economic climate, it is essential that health care professionals justify their assessment intervention objectively.(9,10,14) Certain decisions regarding patient status and treatment are based wholly or in part on joint motion mea…”
Background
Cited by
Fletcher, J. P., & Bandy, W. D. (2008) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2008.2680 · Cited by 304
Effects of thoracic kyphosis and forward head posture on cervical range of motion in older adults
Quek, J., Pua, Y.-H., Clark, R. A., & Bryant, A. L. (2013) · Manual Therapy · doi:10.1016/j.math.2012.07.005 · Cited by 249
“Second, although our ROM and posture measurements were well validated and widely used (Ordway et al., 1997; Tousignant et al., 2000; Malmstrom et al., 2003; Hall et al., 2007, 2008a; Greendale et al., 2011; Takasaki et al., 2011), we acknowledged that they were measured in different positions.”
InfluentialWilliams, M. A., McCarthy, C. J., Chorti, A., Cooke, M. W., & Gates, S. (2010) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2009.12.009 · Cited by 230
Forward Head Posture and Neck Mobility in Chronic Tension-Type Headache: A Blinded, Controlled Study
Fernández-de-las-Peñas, C., Alonso-Blanco, C., Cuadrado, M., & Pareja, J. (2006) · Cephalalgia · doi:10.1111/j.1468-2982.2005.01042.x · Cited by 221
van Niekerk, S.-M., Louw, Q., Vaughan, C., Grimmer-Somers, K., & Schreve, K. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-113 · Cited by 187
“We identified nine relevant papers describing only three measurement approaches (goniometer [17-19], inclinometer [20-23] and flexicurve [24,25]).”
Background
Metadata
- Authors
- Tousignant, M., de Bellefeuille, L., O’Donoughue, S., & Grahovac, S.
- Venue
- Spine
- Published
- 2000-02
- Volume
- 25
- Issue
- 3
- Pages
- 324-330
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2038341332
- Cited by
- 166
- References
- 9
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.