The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Resonance Classification of Lumbar Intervertebral Disc Degeneration
Abstract
STUDY DESIGN: A reliability study was conducted. OBJECTIVES: To develop a classification system for lumbar disc degeneration based on routine magnetic resonance imaging, to investigate the applicability of a simple algorithm, and to assess the reliability of this classification system. SUMMARY OF BACKGROUND DATA: A standardized nomenclature in the assessment of disc abnormalities is a prerequisite for a comparison of data from different investigations. The reliability of the assessment has a crucial influence on the validity of the data. Grading systems of disc degeneration based on state of the art magnetic resonance imaging and corresponding reproducibility studies currently are sparse. METHODS: A grading system for lumbar disc degeneration was developed on the basis of the literature. An algorithm to assess the grading was developed and optimized by reviewing lumbar magnetic resonance examinations. The reliability of the algorithm in depicting intervertebral disc alterations was tested on the magnetic resonance images of 300 lumbar intervertebral discs in 60 patients (33 men and 27 women) with a mean age of 40 years (range, 10-83 years). All scans were analyzed independently by three observers. Intra- and interobserver reliabilities were assessed by calculating kappa statistics. RESULTS: There were 14 Grade I, 82 Grade II, 72 Grade III, 68 Grade IV, and 64 Grade V discs. The kappa coefficients for intra- and interobserver agreement were substantial to excellent: intraobserver (kappa range, 0.84-0.90) and interobserver (kappa range, 0.69-0.81). Complete agreement was obtained, on the average, in 83.8% of all the discs. A difference of one grade occurred in 15.9% and a difference of two or more grades in 1.3% of all the cases. CONCLUSION: Disc degeneration can be graded reliably on routine T2-weighted magnetic resonance images using the grading system and algorithm presented in this investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Cited by
Incremental support vector learning for ordinal regression
Gu, B., Sheng, V. S., Tay, K. Y., Romano, W., & Li, S. (2015) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2014.2342533 · Cited by 707
Lumbar Degenerative Disk Disease
Modic, M. T., & Ross, J. S. (2007) · Radiology · doi:10.1148/radiol.2451051706 · Cited by 499
Sakai, D., Nakamura, Y., Nakai, T., Mishima, T., Kato, S., Grad, S., Alini, M., Risbud, M. V., Chan, D., Cheah, K. S. E., et al. (2012) · Nature Communications · doi:10.1038/ncomms2226 · Cited by 451
Zhang, W., Li, G., Luo, R., Lei, J., Song, Y., Wang, B., Ma, L., Liao, Z., Ke, W., Liu, H., et al. (2022) · Experimental & Molecular Medicine · doi:10.1038/s12276-022-00729-9 · Cited by 325
Chen, D., Xia, D., Pan, Z., Xu, D., Zhou, Y., Wu, Y., Cai, N., Tang, Q., Wang, C., Yan, M., et al. (2016) · Cell Death & Disease · doi:10.1038/cddis.2016.334 · Cited by 314
Metadata
- Authors
- Pfirrmann, C. W. A., Metzdorf, A., Zanetti, M., Hodler, J., & Boos, N.
- Venue
- Spine
- Published
- 2001-09
- Volume
- 26
- Issue
- 17
- Pages
- 1873-1878
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1966188170
- Cited by
- 4,012
- References
- 1
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Classification of Lumbar Intervertebral Disc Degeneration. https://app.cochat.ai/papers/10.1097/00007632-200109010-00011
- The paper
- Pfirrmann, C. W. A., Metzdorf, A., Zanetti, M., Hodler, J., & Boos, N. (2001). Magnetic Resonance Classification of Lumbar Intervertebral Disc Degeneration. Spine. https://doi.org/10.1097/00007632-200109010-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.