Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Spinal Implant Debris-Induced Osteolysis

Hallab, Nadim J., Cunningham, Brian W., Jacobs, Joshua J. · 2003 · Spine

Abstract

STUDY DESIGN: Generally, implant-induced osteolysis is a manifestation of an adverse cellular response to phagocytosable particulate wear and corrosion debris. Initially termed "cement disease," particle-induced loosening was recognized by Charnley in the early 1960s. Despite the plethora of information gained over the last 40 years on the basic science of periprosthetic bone loss, much remains unanswered. The effect of unintended debris resulting from wear and corrosion (e.g., micromotion between the interconnection mechanisms in spinal implants) remains a clinical concern. The current study highlights what is known of particle-induced osteolysis and how the presence of spinal implant particulate debris deleteriously influences osseointegration of posterolateral bone graft or disrupts an established posterolateral fusion mass. Tissue explant, animal, and cell culture studies have revealed the complexity of cellular reactivity involved in aseptic particle-induced osteolysis. OBJECTIVES: The objectives of this study are twofold: 1) to highlight the dominant cellular participants in total joint arthroplasty particle induced osteolysis, which are purportedly the macrophage, osteoblast, fibroblast, and osteoclast and several of the dominant chemical mediators have been identified as well, which include prostaglandin E2, tumor necrosis factor-alpha, interleukin-1, and interleukin-6; and 2) to demonstrate the potential deleterious effects of spinal implant debris using animal models and analysis of soft tissue surrounding spinal implants in symptomatic patients. METHODS: There are a growing number of proinflammatory and anti-inflammatory cytokines, prostenoids, and enzymes that have been shown to play important roles in the pathology of particle-induced osteolysis. Reports that aseptic granulomatous inflammation typical of that associated with corrosion debris appear to correlate with the complexity of the implant. Titanium particulate material was used to induce effects in 34 New Zealand White rabbits where analysis included serological quantification of systemic cytokines. Postmortem microradiographic, immunocytochemical, and histopathologic assessment of the intertransverse fusion mass quantified the extent of osteolysis, local proinflammatory cytokines, osteoclasts and inflammatory infiltrates. Clinical analysis of 12 patients more than 0.4 years after spinal implants (mean 4.03, range 0.4 to 11 years) presented with late operative site pain. RESULTS: Currently the etiology of this inflammation around spinal implants resembles particle-induced osteolysis around joint arthroplasties where there typically is a self-perpetuating fibroinflammatory zone adjacent to the implant, where macrophage exhaustion, reactive oxygen intermediates, and pro-inflammatory cytokines affect a host of local cell types and induce a widening zone of soft tissue damage and inflammation. Animal model analysis indicated increased levels of local inflammatory cytokines typically associated with osteolysis-tumor necrosis factor-alpha. Osteoclast cell counts and regions of osteolytic resorption lacunas were higher in the titanium-treated versus autograft-alone groups (P < 0.05), and the extent of cellular apoptosis was markedly higher in the titanium-treated sites at both time intervals. Electron microscopy indicated definitive evidence of phagocytized titanium particles and foci of local, chronic inflammatory changes in the titanium-treated sites. CLINICAL CASES: 11 of 12 clinical cases demonstrated elevated tumor necrosis factor-alpha levels and an increased osteoclastic response in the vicinity of wear debris caused by dry frictional wear particles of titanium or stainless steel. Resection of the wear debris and surrounding fibroinflammatory zone resolved clinical symptoms in all 12 cases. CONCLUSIONS: More basic science and clinical research is needed to develop novel strategies for gaining knowledge, and developing effective evaluation and treatment of patients with implant debris related osteolysis. Titanium debris simulating that produced by spinal implants introduced at the level of a spinal arthrodesis elicits an inflammatory cytokine mediated particulate-induced response through increased expression of intracellular TNF-alpha, increased osteoclastic activity and cellular apoptosis. This study highlighted the association between spinal implants particulate wear debris and increased potential for osteolysis. Aseptic osteolysis is among the primary reasons for failure of orthopedic implants. Increased awareness of this destructive process is becoming more important with the growing popularity of total disc arthroplasty and highly modular spinal implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-200310151-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 201

Metadata

Authors
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J.
Venue
Spine
Published
2003-10
Volume
28
Issue
Supplement
Pages
S125-S138
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2011463553
Cited by
201
References
1
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spinal Implant Debris-Induced Osteolysis. https://app.cochat.ai/papers/10.1097/00007632-200310151-00006
The paper
Hallab, N. J., Cunningham, B. W., & Jacobs, J. J. (2003). Spinal Implant Debris-Induced Osteolysis. Spine. https://doi.org/10.1097/00007632-200310151-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.