Implant osseointegration and the role of microroughness and nanostructures: Lessons for spine implants
Open accessAbstract
The use of spinal implants for spine fusion has been steadily increasing to avoid the risks of complications and donor site morbidity involved when using autologous bone. A variety of fusion cages are clinically available, with different shapes and chemical compositions. However, detailed information about their surface properties and the effects of such properties on osteogenesis is lacking in the literature. Here we evaluate the role of surface properties for spinal implant applications, covering some of the key biological processes that occur around an implant and focusing on the role of surface properties, specifically surface structure, on osseointegration, drawing examples from other implantology fields when required. Our findings revealed that surface properties such as micro-roughness and nanostructures can directly affect early cell behavior and long-term osseointegration. Micro-roughness has been well established in the literature to have a beneficial effect on osseointegration of implants. In the case of the role of nanostructures, the number of reports is increasing and most studies reveal a positive effect from the nanostructures alone and a synergistic effect when combined with micro-rough surfaces. Still, long-term clinical results are necessary to establish the full implications of surface nanomodifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
Bone Resorption by Osteoclasts
Teitelbaum, S. L. (2000) · Science · doi:10.1126/science.289.5484.1504 · Cited by 3,962
Mesenchymal stem cells as trophic mediators
Caplan, A. I., & Dennis, J. E. (2006) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20886 · Cited by 2,992
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
Brånemark, P. I., Hansson, B. O., Adell, R., Breine, U., Lindström, J., Hallén, O., & ÖHMAN, A. E. (1977) · PubMed · Cited by 2,385
Platelet-rich plasma: evidence to support its use
Marx, R. E. (2004) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2003.12.003 · Cited by 1,942
Genetic regulation of osteoclast development and function
Teitelbaum, S. L., & Ross, F. P. (2003) · Nature Reviews Genetics · doi:10.1038/nrg1122 · Cited by 1,701
Mediation of biomaterial-cell interactions by adsorbed proteins: a review
Wilson, C. J., Clegg, R. E., Leavesley, D. I., & Pearcy, M. J. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1 · Cited by 1,696
Reaching a Genetic and Molecular Understanding of Skeletal Development
Karsenty, G., & Wagner, E. F. (2002) · Developmental Cell · doi:10.1016/s1534-5807(02)00157-0 · Cited by 1,601
Owen, T. A., Aronow, M., Shalhoub, V., Barone, L. M., Wilming, L., Tassinari, M. S., Kennedy, M. B., Pockwinse, S., Lian, J. B., & Stein, G. S. (1990) · Journal of Cellular Physiology · doi:10.1002/jcp.1041430304 · Cited by 1,567
Cited by
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Yuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.014 · Cited by 204
Cao, C., Huang, P., Prasopthum, A., Parsons, A. J., Ai, F., & Yang, J. (2022) · Biomaterials Science · doi:10.1039/d1bm01645h · Cited by 65
Metadata
- Authors
- Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2014-08
- Volume
- 10
- Issue
- 8
- Pages
- 3363-3371
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W2084960929
- Cited by
- 447
- References
- 88
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implant osseointegration and the role of microroughness and nanostructures: Lessons for spine implants. https://app.cochat.ai/papers/10.1016/j.actbio.2014.03.037
- The paper
- Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D. (2014). Implant osseointegration and the role of microroughness and nanostructures: Lessons for spine implants. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2014.03.037
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.