CoChat

Evaluation of a New Standardized Ramp Protocol: The BSU/Bruce Ramp Protocol

Kaminsky, Leonard A., Whaley, Mitchell H. · 1998 · Journal of Cardiopulmonary Rehabilitation
Cited by 127

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Because of recent technological advances, exercise testing laboratories now have the ability to use ramp protocols with treadmill exercise tests. Since the Bruce protocol is the most widely used treadmill protocol in clinical laboratories, a standardized ramp treadmill protocol was developed that corresponds to the speed and grade settings of the Bruce protocol at each 3-minute time interval. The purpose of this study was to evaluate the utility of using subject demographic and exercise test data to predict peak oxygen uptake (VO2peak) for tests conducted with the BSU/Bruce Ramp protocol. METHODS: Maximal exercise tests were performed by 698 men and women using the BSU/Bruce Ramp protocol. Peak oxygen uptake was measured during all tests. Stepwise multiple regression analyses were used to predict VO2peak (mL.kg-1.min-1) from maximal treadmill test time and selected variables including age, gender, physical activity habits, and body weight. RESULTS: Maximal test time was found to be the most potent predictor of VO2peak, accounting for 86% of the variance in peak aerobic power, with a standard error of estimate of 3.4 mL kg min-1. A multiple regression equation including age, gender, physical activity habits, and body weight resulted in a slightly improved prediction (R2 = 0.88; standard error of estimates = 3.1 mL kg min-1). CONCLUSIONS: Peak oxygen uptake values can be predicted with reasonable accuracy from the BSU/Bruce Ramp protocol. The BSU/Bruce Ramp would be an excellent choice for laboratories desiring to use a ramp treadmill protocol because of the design of the protocol with identical workloads at equivalent time periods (3, 6, 9, 12, 15, 18, 21 minutes) as the commonly used Bruce protocol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00008483-199811000-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 11

  1. Bruce, 1973, Am Heart J, 85, 546, 10.1016/0002-8703(73)90502-4 · DOI · Paper page
  2. Myers, 1990, Circulation, 82, 1839, 10.1161/01.CIR.82.5.1839 · DOI
  3. Panza, 1991, J Am Coll Cardiol, 17, 657, 10.1016/S0735-1097(10)80180-9 · DOI
  4. Whipp, 1981, J Appl Physiol, 50, 217, 10.1152/jappl.1981.50.1.217 · DOI · Paper page
  5. Myers, 1992, Chest, 101, 236S
  6. Kaminsky, 1993, Med Sci Sports Exerc, 25, S13, 10.1249/00005768-199311000-00014 · DOI
  7. Whaley, 1995, Med Sci Sports Exerc, 27, 85
  8. Buchfuhrer, 1983, J Appl Physiol, 55, 1558, 10.1152/jappl.1983.55.5.1558 · DOI · Paper page
  9. 1990, Circulation, 82, 2286, 10.1161/01.CIR.82.6.2286 · DOI · Paper page
  10. Froelicher, 1974, J Appl Physiol, 36, 720, 10.1152/jappl.1974.36.6.720 · DOI
  11. Pollock, 1982, Am Heart J, 103, 363, 10.1016/0002-8703(82)90275-7 · DOI · Paper page

Cited by

See all 127

Metadata

Authors
Kaminsky, L. A., & Whaley, M. H.
Venue
Journal of Cardiopulmonary Rehabilitation
Published
1998-11
Volume
18
Issue
6
Pages
438-444
ISSN
0883-9212 (ISSN-L)
OpenAlex
W2083045323
Cited by
127
References
1
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a New Standardized Ramp Protocol: The BSU/Bruce Ramp Protocol. https://app.cochat.ai/papers/10.1097/00008483-199811000-00006
The paper
Kaminsky, L. A., & Whaley, M. H. (1998). Evaluation of a New Standardized Ramp Protocol: The BSU/Bruce Ramp Protocol. Journal of Cardiopulmonary Rehabilitation. https://doi.org/10.1097/00008483-199811000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.