Evaluation of a New Standardized Ramp Protocol: The BSU/Bruce Ramp Protocol
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Because of recent technological advances, exercise testing laboratories now have the ability to use ramp protocols with treadmill exercise tests. Since the Bruce protocol is the most widely used treadmill protocol in clinical laboratories, a standardized ramp treadmill protocol was developed that corresponds to the speed and grade settings of the Bruce protocol at each 3-minute time interval. The purpose of this study was to evaluate the utility of using subject demographic and exercise test data to predict peak oxygen uptake (VO2peak) for tests conducted with the BSU/Bruce Ramp protocol. METHODS: Maximal exercise tests were performed by 698 men and women using the BSU/Bruce Ramp protocol. Peak oxygen uptake was measured during all tests. Stepwise multiple regression analyses were used to predict VO2peak (mL.kg-1.min-1) from maximal treadmill test time and selected variables including age, gender, physical activity habits, and body weight. RESULTS: Maximal test time was found to be the most potent predictor of VO2peak, accounting for 86% of the variance in peak aerobic power, with a standard error of estimate of 3.4 mL kg min-1. A multiple regression equation including age, gender, physical activity habits, and body weight resulted in a slightly improved prediction (R2 = 0.88; standard error of estimates = 3.1 mL kg min-1). CONCLUSIONS: Peak oxygen uptake values can be predicted with reasonable accuracy from the BSU/Bruce Ramp protocol. The BSU/Bruce Ramp would be an excellent choice for laboratories desiring to use a ramp treadmill protocol because of the design of the protocol with identical workloads at equivalent time periods (3, 6, 9, 12, 15, 18, 21 minutes) as the commonly used Bruce protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparative analysis of four protocols for maximal treadmill stress testing
Pollock, M. L., Bohannon, R. L., Cooper, K. H., Ayres, J. J., Ward, A., White, S. R., & Linnerud, A. C. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80401-2 · Cited by 536
Research works printed but not linked: 11
- Bruce, 1973, Am Heart J, 85, 546, 10.1016/0002-8703(73)90502-4 · DOI · Paper page
- Myers, 1990, Circulation, 82, 1839, 10.1161/01.CIR.82.5.1839 · DOI
- Panza, 1991, J Am Coll Cardiol, 17, 657, 10.1016/S0735-1097(10)80180-9 · DOI
- Whipp, 1981, J Appl Physiol, 50, 217, 10.1152/jappl.1981.50.1.217 · DOI · Paper page
- Myers, 1992, Chest, 101, 236S
- Kaminsky, 1993, Med Sci Sports Exerc, 25, S13, 10.1249/00005768-199311000-00014 · DOI
- Whaley, 1995, Med Sci Sports Exerc, 27, 85
- Buchfuhrer, 1983, J Appl Physiol, 55, 1558, 10.1152/jappl.1983.55.5.1558 · DOI · Paper page
- 1990, Circulation, 82, 2286, 10.1161/01.CIR.82.6.2286 · DOI · Paper page
- Froelicher, 1974, J Appl Physiol, 36, 720, 10.1152/jappl.1974.36.6.720 · DOI
- Pollock, 1982, Am Heart J, 103, 363, 10.1016/0002-8703(82)90275-7 · DOI · Paper page
Cited by
Ross, R., Blair, S. N., Arena, R., Church, T. S., Després, J.-P., Franklin, B. A., Haskell, W. L., Kaminsky, L. A., Levine, B. D., Lavie, C. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000461 · Cited by 2,486
Self-citationFletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Fletcher, G. F., Balady, G. J., Amsterdam, E. A., Chaitman, B., Eckel, R., Fleg, J., Froelicher, V. F., Leon, A. S., Piña, I. L., Rodney, R., et al. (2001) · Circulation · doi:10.1161/hc3901.095960 · Cited by 1,923
Perin, E. C., Dohmann, H. F. R., Borojevic, R., Silva, S. A., Sousa, A. L. S., Mesquita, C. T., Rossi, M. I. D., Carvalho, A. C., Dutra, H. S., Dohmann, H. J. F., et al. (2003) · Circulation · doi:10.1161/01.cir.0000070596.30552.8b · Cited by 1,290
Exercise interventions on health-related quality of life for cancer survivors
Mishra, S. I., Scherer, R. W., Geigle, P. M., Berlanstein, D. R., Topaloglu, O., Gotay, C. C., & Snyder, C. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007566.pub2 · Cited by 808
Reference Standards for Cardiorespiratory Fitness Measured With Cardiopulmonary Exercise Testing
Kaminsky, L. A., Arena, R., & Myers, J. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2015.07.026 · Cited by 461
Self-citationCardiorespiratory Fitness and Mortality in Healthy Men and Women
Imboden, M. T., Harber, M. P., Whaley, M. H., Finch, W. H., Bishop, D. L., & Kaminsky, L. A. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.2166 · Cited by 276
Self-citationBlumenthal, J. A., Sherwood, A., Smith, P. J., Watkins, L., Mabe, S., Kraus, W. E., Ingle, K., Miller, P., & Hinderliter, A. (2016) · Circulation · doi:10.1161/circulationaha.115.018926 · Cited by 257
Lang, J. J., Prince, S. A., Merucci, K., Cadenas-Sanchez, C., Chaput, J.-P., Fraser, B. J., Manyanga, T., McGrath, R., Ortega, F. B., Singh, B., et al. (2024) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-107849 · Cited by 220
Ramp Exercise Protocols for Clinical and Cardiopulmonary Exercise Testing
Myers, J., & Bellin, D. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00003 · Cited by 192
“[4-10] Clinically, the potential importance of these findings include improved diagnostic performance, a more accurate estimate of exercise capacity and improved utility of the exercise test for estimating prognosis, developing an exercise prescription or assessing submaximal responses such as the ventilatory threshol…”
BackgroundKahn, S. R., Shrier, I., Shapiro, S., Houweling, A. H., Hirsch, A. M., Reid, R. D., Kearon, C., Rabhi, K., Rodger, M. A., Kovacs, M. J., et al. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.100248 · Cited by 164
“Before randomization, potentially eligible patients were given a physician-supervised exercise stress test using the modified Bruce ramp protocol.(11) Patients whose exercise test was stopped for reasons other than fatigue alone (e.”
MethodCaplin, A., Chen, F. S., Beauchamp, M. R., & Puterman, E. (2021) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2021.105336 · Cited by 142
“Participants were then asked to complete a modified cardiopulmonary exercise treadmill test (CPET) at maximal capacity (Kaminsky and Whaley, 1998).”
MethodBourke, L., Thompson, G., Gibson, D. J., Daley, A., Crank, H., Adam, I., Shorthouse, A., & Saxton, J. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.12.020 · Cited by 118
Ozemek, C., Cochran, H. L., Strath, S. J., Byun, W., & Kaminsky, L. A. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-53 · Cited by 69
“The BSU/Bruce Ramp protocol was used for the maximal exercise test at BSU, while the Bruce Protocol was performed by subjects at UWM [28,29].”
MethodInfluentialSelf-citationTsai, Y.-J., Li, M.-H., Tsai, W.-J., Tuan, S.-H., Liao, T.-Y., & Lin, K.-L. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487315623405 · Cited by 44
Maximal heart rate declines linearly with age independent of cardiorespiratory fitness levels
Ozemek, C., Whaley, M. H., Finch, W. H., & Kaminsky, L. A. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2016.1275042 · Cited by 25
Self-citationEstimating maximal oxygen consumption from heart rate response to submaximal ramped treadmill test
Gonzales, T. I., Westgate, K., Hollidge, S., Lindsay, T., Jeon, J., & Brage, S. (2020) · doi:10.1101/2020.02.18.20024489 · Cited by 7
Metadata
- Authors
- Kaminsky, L. A., & Whaley, M. H.
- Venue
- Journal of Cardiopulmonary Rehabilitation
- Published
- 1998-11
- Volume
- 18
- Issue
- 6
- Pages
- 438-444
- ISSN
- 0883-9212 (ISSN-L)
- OpenAlex
- W2083045323
- Cited by
- 127
- References
- 1
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.