Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
The DOI matches its Crossref record; 17 of the 19 references it cites were found in a registry or an index.
Abstract
In Brief Myoelectrically powered prosthetic hands lack sensory feedback relating to the force exerted by the artificial hand on a grasped object. The degree of control is imprecise, and often much more force than necessary is applied. The aim of this study was to develop and evaluate a force feedback system considering design constraints, providing the user with closed-loop control. Different methods and design criteria for providing myoelectric prosthetic hands with force feedback were analyzed, with stimulation by vibration being preferred. A new feedback system was designed, consisting of a miniature vibration motor, a piezoresistive force sensor, and control electronics. Grasping forces with and without feedback were recorded and compared from five habitual myoelectric hand users when grasping a hand dynamometer with different weights attached to it. All five patients rapidly improved their ability to regulate the grasping force without the help of vision when feedback was applied. An average force reduction of 37% was found when vibration was applied indirectly to the hand, and a decrease of 54% was found when feedback was applied directly to the skin of the residual limb. Constraints for a prosthetic force feedback system such as low power consumption, compactness, and being imperceptible to others are included in the design. General acceptance of vibration as a feedback signal was good, especially when applied indirectly. The results indicate that the new system is of potential value for myoelectric prosthetic hand users. More precise control is possible, and redundant grasping force can be diminished with a feedback system. A new system may offer valuable assistance to myoelectric prosthetic hand users to more accurately gauge the force needed for a particular task. People with such artificial hands suffer from a lack of adequate feedback compared with body-powered prostheses. Different methods for providing myoelectric prosthetic hands with force feedback were analyzed, and a new feedback system was designed, consisting of a sensor capable of changing its resistance under physical pressure, a miniature vibration motor, and control electronics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Sensory substitution, such as vibration on a residual limb with intensity proportional to pressure at the prosthetic fingertip, improves prosthetic control in limited situations (8, 9), but has not been widely adopted as the vibration is often described as distracting (8).”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [8]
Citations
Cites
Factors influencing the force control during precision grip
Westling, G., & Johansson, R. S. (1984) · Experimental Brain Research · doi:10.1007/bf00238156 · Cited by 1,027
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“Moreover, the range of signal current between the detection threshold (1 mA) and pain threshold (2 mA) is narrow, and pain sensations are reported to be the major disadvantage of electrotactile stimulation.(7,13) For this reason, other researchers proposed vibration(10,14,15) or pressure(16,17) to transmit information.”
BackgroundBunnell, S. (1949) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-194905000-00012 · Cited by 764
Effect of Contactor Area on the Vibrotactile Threshold
Verrillo, R. T. (1963) · The Journal of the Acoustical Society of America · doi:10.1121/1.1918868 · Cited by 381
Closed-loop control in prosthetic systems: Historical perspective
Childress, D. S. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363433 · Cited by 158 · cited 1×
“Since then, research groups all over the world have designed force and velocity feedback systems.(5,6) Of the several feedback principles published and discussed extensively in the last decades, two are considered to have the best clinical viability: electrical surface stimulation (ESS) and mechanical surface stimulat…”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“An advantage associated with mechanical stimulation for force feedback is the universal psychological acceptance.(7,16) However, the actuators used for mechanical feedback have been too bulky and could not be integrated in a prosthetic hand.”
BackgroundA comparison of alternative means of providing sensory feedback on upper limb prostheses
Shannon, G. F. (1976) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478123 · Cited by 93 · cited 3×
“Moreover, the range of signal current between the detection threshold (1 mA) and pain threshold (2 mA) is narrow, and pain sensations are reported to be the major disadvantage of electrotactile stimulation.(7,13) For this reason, other researchers proposed vibration(10,14,15) or pressure(16,17) to transmit information.”
BackgroundSENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 92
A myoelectrically-controlled prosthesis with sensory feedback
Shannon, G. F. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440956 · Cited by 92 · cited 2×
“This confirms the statements made by Shannon.22 Two of the test persons remarked that the vibration signal becomes more disturbing than helpful after some seconds.”
ResultA shoulder pad insert vibrotactile display
Toney, A., Dunne, L. E., Thomas, B. H., & Ashdown, S. P. (2004) · Proceedings · doi:10.1109/iswc.2003.1241391 · Cited by 72
Research works printed but not linked: 3
- Shannon, 1974, Biomed Eng, 9, 247
- Pylatiuk, 2005, Biomed Eng, 50, 1521
- Kargov, 2004, Technol Health Care, 12, 193
Cited by
Items 101–156 of 156
Dosen, S. S., Prahm, C., Amsuess, S., Vujaklija, I., & Farina, D. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_15 · Cited by 10
Contextual effects on robotic experiments of sensory feedback for object manipulation
Stepp, C. E., Dellon, B., & Matsuoka, Y. (2010) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2010.5627824 · Cited by 9
“[10], who designed a feedback system for myoelectric prosthetic hands in which contact forces felt via a piezo-resistive force sensor on the palmar tip of the prosthesis were represented to the user by vibrotactile stimulation of the prosthesis or skin of the residual limb.”
BackgroundMethodProviding contact sensory feedback for upper limb robotic prosthesis
Aziziaghdam, M., & Samur, E. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775519 · Cited by 8
“To overcome this dependence on vision, there has been considerable effort to provide sensory feedback for robotic prostheses focusing on grasp force [2, 3, 4, 5, 6, 7, 8, 9] or joint angle position [10, 11] feedback.”
BackgroundSpatial discrimination learning of electrocutaneous stimuli is influenced by the type of stimulation
Walter-Walsh, K., Weiß, T., Spohn, D., Torma, F., & Miltner, W. H. R. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.055 · Cited by 10
Ko, C., Chang, Y., Kim, S., Kim, S.-K., Kim, G., Ryu, J., & Mun, M.-S. (2014) · Physiology & Behavior · doi:10.1016/j.physbeh.2014.10.021 · Cited by 9
“Displeasure can be one of the main reasons to restrain from using VS as an SFSD.”
BackgroundInfluentialElectro-tactile Feedback System for a Prosthetic Hand
Pamungkas, D. S., & Ward, K. (2015) · Research Online (University of Wollongong) · Cited by 11
Multi-channel Electro-tactile Feedback System for a Prosthetic Hand
Ward, K., & Pamungkas, D. S. (2018) · Springer eBooks · doi:10.1007/978-3-319-76947-9_13 · Cited by 9
“Interfacing force sensors to the amputee is achieved either by surgically implanting electrodes that stimulate sensory nerves (see [7] and [8]), or through non-invasive feedback methods involving the use of vibrators [9], air pressure [10] or spatiallymapped tactile displays involving pressure, vibration, shear force…”
BackgroundReal-Time Contact Sensory Feedback for Upper Limb Robotic Prostheses
Aziziaghdam, M., & Samur, E. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2709547 · Cited by 7
Xiong, Q., Yao, H., Wang, J., Huang, Z., Luo, J., Zhong, C., Lin, Y., & Shu, L. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1519758 · Cited by 7
Yoshikawa, D., Kawamoto, H., & Sankai, Y. (2019) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2019.8914074 · Cited by 6
Erwin, A., & Sup, F. C. (2014) · IEEE Haptics Symposium · doi:10.1109/haptics.2014.6775507 · Cited by 6
“Devices that utilize vibrotactile stimulation have found applications ranging from feedback for prosthetics [8] to use in the operating room [7].”
BackgroundAdvantages of externally powered prosthesis with feedback system using pseudo-cineplasty
Nambu, S., Ikebuchi, M., Taniguchi, M., Park, C. S., Kitagawa, T., Nakajima, S., & Koike, T. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.03.0067 · Cited by 8
“Various research institutions have been investigating methods for moving myoelectric hand prostheses in ways that are not as susceptible to erroneous activation and can provide sensory feedback [3–6].”
Nemah, M. N., Aldulaymi, O. H., Low, C. Y., Zakaria, N. A. C., & Mohamaddan, S. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/834/1/012013 · Cited by 5
The Mind-Controlled Robotic Hand
Lundborg, G. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5334-4_16 · Cited by 4
Compliance Perception Using Natural and Artificial Motion Cues
Gurari, N., & Okamura, A. M. (2014) · Springer series on touch and haptic systems · doi:10.1007/978-1-4471-6533-0_10 · Cited by 5
Discrimination of Springs with Vision, Proprioception, and Artificial Skin Stretch Cues
Gurari, N., Wheeler, J. W., Shelton, A. L., & Okamura, A. M. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-31401-8_15 · Cited by 4
Bao, L., Zhang, D., Xu, H., & Zhu, X. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-22879-2_29 · Cited by 4
Enhancing human computer interaction with electrotactile feedback
Pamungkas, D. S. (2016) · Research Online (University of Wollongong) · Cited by 5
Ko, C., Chang, Y., Kim, S., Kim, S.-K., Kim, G., Ryu, J., & Mun, M.-S. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4025777 · Cited by 3
Clinical evaluation of Hannes: measuring the usability of a novel polyarticulated prosthetic hand
Semprini, M., Boccardo, N., Lince, A., Traverso, S., Lombardi, L., Succi, A., Canepa, M., Squeri, V., Saglia, J. A., Ariano, P., et al. (2022) · Elsevier eBooks · doi:10.1016/b978-0-32-390445-2.00020-9 · Cited by 7
Hand prosthesis prototype controlled by EMG and vibrotactile force feedback
Sono, T. S. P., Menegaldo, L. L., & Pinotti, M. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913758 · Cited by 3
A scalable, high resolution strain sensing matrix suitable for tactile transduction
Scibelli, A. E., & Krans, J. L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.056 · Cited by 3
“Integrated sensory feedback can provide error control to a local circuit, which in turn could provide users with more effective and precise control (Pylatiuk et al., 2006)”
BackgroundWeir, R. F. F. (2017) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000161 · Cited by 3
Elucidating Sensorimotor Control Principles with Myoelectric Musculoskeletal Models
Goodman, S. E., & Hasson, C. J. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00531 · Cited by 4
“Several studies have shown that vibrotactile force feedback improves performance with both simulated (MMMs) and real myoelectric prosthetic arms (Patterson and Katz, 1992; Pylatiuk et al., 2006; Chatterjee et al., 2008a,b; Stepp and Matsuoka, 2010; Rombokas et al., 2013).”
BackgroundDevelopment of a bio-inspired MEMS based tactile sensor array for an artificial finger
Muhammad, H. B. (2012) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 4
Achievement of a Multi DOF Myoelectric Interface for Hand Prosthesis
Benchabane, S. I., Saadia, N., & Ramdane-Chérif, A. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41000-5_64 · Cited by 2
An Integrated Force Feedback System for a Prosthetic Hand
von Brockdorff, C., Aquilina, Y., Cauchi, R., Saliba, M. A., Attard, J., & Camilleri, K. P. (2022) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon49645.2022.9969077 · Cited by 2
“It has also been reported that mechanical stimulation for force feedback is psychologically universally acceptable while electrical surface stimulation is trickier due to reported pain sensations [6].”
BackgroundA review of haptic technologies for hardware-in-the-loop development
Ajayi, O. K., Du, S., & Nahri, S. N. F. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100331 · Cited by 5
Benchabane, S. I., & Saadia, N. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-20472-7_20 · Cited by 2
Displaying centre of pressure location by electrotactile stimulation using phantom sensation
Pfeifer, S., Çaldıran, O., Vallery, H., Riener, R., & Arieta, A. H. (2010) · Zurich Open Repository and Archive (University of Zurich) · doi:10.5167/uzh-42438 · Cited by 3
“As an example, vibration on the skin of the residual limb can encode grasping force in a prosthetic hand [2].”
BackgroundOn sensory feedback in hand prostheses
Antfolk, C. (2012) · Lund University Publications (Lund University) · Cited by 5
Pan, L., Lun, J., Ren, Z., Zhao, H., Mu, R., & Li, J. (2025) · Journal of Bionic Engineering · doi:10.1007/s42235-025-00810-9 · Cited by 2
Kim, S., Chang, Y.-H., Kim, S.-K., Kim, G., Mun, M.-S., & Bae, T.-S. (2012) · Journal of the Korean Society for Precision Engineering · doi:10.7736/kspe.2012.29.7.705 · Cited by 1
“근전동 의수(myoelectrical hand prosthesis)의 개발 은 상지 절단자의 손 기능 회복과 일상 생활 활동 을 촉진시켜 사회 복귀 및 삶의 질을 향상시켰다.(1) 그러나 근전동 의수는 시각이 차단될 경우 의수 조절에 어려움이 따르며, 시각 피드백 외에 다른 감각으로 쥐기(grip) 능력과 고유수용감각 정보를 피드백 받을 수 없다는 제한점이 있다.”
Elbow Disarticulation Amputation
Shives, T. C., & Andrews, K. L. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4160-2902-1.50078-4 · Cited by 1
Moving sliding mode control for sEMG based prosthetic hand
Taşar, B., Tanyıldızı, A. K., Gülten, A., & Yakut, O. (2018) · Biomedical Research - India · doi:10.4066/biomedicalresearch.29-18-461 · Cited by 1
“have proposed and used feedback-controlled methods for controlling the gripping force of the prosthetic hand in their work [11,12].”
MethodSimplified Closed-Loop Thermal Feedback System in Flexible form Factor for Prosthesis
Park, W., & Yu, X. (2023) · IEEE International Conference on Nanotechnology (IEEE-NANO) · doi:10.1109/nano58406.2023.10231315 · Cited by 1
Design and Development of a Low-Cost Force Feedback 3D Printed Myoelectric Hand Prosthesis
Al-Madani, F., Kassab, M., Sonmez, B. Z., & Solmaz, H. (2017) · National Biomedical Engineering Meeting · doi:10.1109/biyomut.2017.8479096 · Cited by 1
“[6] Christian Pylatiuk, Artem Kargov, Stefan Schulz, “Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands”, JPO Journal of Prosthetics and Orthotics, Volume 18 • Number 2 • 2006 [7] http://www.”
BackgroundProviding Non-Invasive Sensory Feedback for Transradial Prosthetic Hand Users
Stephens-Fripp, B. (2020) · Research Online (University of Wollongong) · Cited by 1
Tactile feedback for myoelectric forearm prostheses
Witteveen, H. J. B. (2013) · doi:10.3990/1.9789036535885 · Cited by 2
Application of haptic feedback to a combot
McAmis, S., & Reed, K. B. (2012) · IEEE Haptics Symposium · doi:10.1109/haptic.2012.6183846
“Haptically rendering the current and temperature information allows the operator to make judgements regarding the condition of the motors without distracting him from events inside the arena.”
BackgroundDESIGN AND PRELIMINARY EXPERIENCE WITH FLUIDHAND MK III
Schulz, S., Pylatiuk, C., Kargov, A., Werner, T., Gaiser, I., Reischl, M., & Oberle, R. (2008) · DukeSpace (Duke University)
Self-citationBody Awareness in Prosthetic Hands
Arieta, A. H., & Damian, D. D. (2012) · CRC Press eBooks · doi:10.1201/b13729-9
Sensor Fusion for Closed-loop Control of Upper-limb Prostheses
Marković, M. (2016) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-5733 · Cited by 2
Sensing Feedback for the Control of Multi-joint Prosthetic Hand
Wołczowski, A. R., Głębocki, M., & Jakubiak, J. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-48944-5_22
Nakagawa, M., Sasao, K., Ishioka, T., Suzuki, M., & Hamaguchi, T. (2019) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000243
Elbow Disarticulation Amputation
Andrews, K. L., Carlsen, B. T., & Shives, T. C. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-34169-1.00120-0
FREKVENCIJSKO KODOVANJE VIBROTAKTILNE POVRATNE SPREGE
Bulatović, J. (2020) · Zbornik radova Fakulteta tehničkih nauka u Novom Sadu · doi:10.24867/11be07bulatovic
Wells, E. D. (2021) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r3-h59b-p194
Proportional and Multi-Stimulations Haptic Device for Active Upper Limbs Prosthetics Control
Benchabane, S. I., Saadia, N., Hina, M. D., & Ramdane-Chérif, A. (2021) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-78284-9_12
Opinions on noninvasive sensory feedback of upper limb prosthetic users
Smither, F. C., Andrews, K. L., Scrabeck, T. L., Lennon, R. J., & Zhao, K. D. (2022) · Prosthetics and Orthotics International · doi:10.1097/pxr.0000000000000160 · Cited by 2
“Surface texture 14 (10) 14 (10) 17 (12) 20 (15) 72 (53)”
Real-time vibrotactile pattern generation and identification using discrete event-driven feedback
Erbaş, İ., & Güçlü, B. (2023) · Somatosensory & Motor Research · doi:10.1080/08990220.2023.2175811 · Cited by 1
“Previous studies have shown that vibrotactile feedback can help regulating grasp force (Pylatiuk et al. 2006; Chatterjee et al. 2008; Saunders and Vijayakumar 2011; Witteveen et al. 2014).”
BackgroundMamidanna, P. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561808227
Design and Fabrication of Flexible Wearable Devices: a Review
Jahanshahi, A., & bidhendi, M. N. (2024) · Journal of Association of Electrical and Electronics Engineers · doi:10.61186/jiaeee.21.1.63
Hayashi, T., & Yoshimura, N. (2022) · Journal of Current Scientific Research · doi:10.14302/issn.2766-8681.jcsr-22-4400
Vers un contrôle sensori-moteur bio-inspiré des prothèses myoélectriques du membre supérieur
Guémann, M. (2019) · theses.fr (ABES) · doi:10.70675/258d8d05z8ac0z4098za529z537005e4fba0
Evaluation of a Virtual Box and Blocks Test (BBT) for Assessing Upper Limb Prosthetic Dexterity
Carlson, J. S., Surkin, J. A. W., & Gates, D. H. (2026) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob66782.2026.11681215 · Cited by 1
“For example, electrotactile [9], mechanotactile [10], or vibrotactile feedback [11] have been used to communicate prosthesis-related information, such as joint position or grasping force, by applying vibration or pressure to the user’s arm.”
Metadata
- Authors
- Pylatiuk, C., Kargov, A., & Schulz, S.
- Corresponding author
- Pylatiuk, Christian
- Venue
- JPO Journal of Prosthetics and Orthotics
- Published
- 2006-04
- Volume
- 18
- Issue
- 2
- Pages
- 57-61
- ISSN
- 1040-8800 (ISSN-L)
- OpenAlex
- W2053247083
- Cited by
- 156
- References
- 19
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 5 · 2022: 5 · 2021: 7 · 2020: 7 · 2019: 11 · 2018: 8 · 2017: 11 · 2016: 11 · 2015: 14 · 2014: 17 · 2013: 13 · 2012: 16
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- JPO Journal of Prosthetics and Orthotics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Keywords
- myoelectric prosthetic hand, force feedback, vibration feedback, piezoresistive force sensor, grip force control, feedback control, low-cost prosthetic design, hand dynamometer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.