Segmental bioelectrical impedance analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: The bioelectrical impedance analysis method is a non-invasive, rapid accurate and practical method for assessing body composition. During last decade evidence has been gathered that supports the use of this method to monitor hydration status. This review critically examines different approaches and applications of segmental bioelectrical impedance analysis in the healthy and clinical situations. RECENT FINDINGS: Segmental bioelectrical impedance analysis may be useful to assess appendicular lean body mass, to estimate muscle volume and to investigate possible relationships between muscle size and strength in a limited segment of the limb. The method may become a tool for the bedside detection of fluid accumulation in critical care. SUMMARY: This is a review of segmental bioelectrical impedance. The preponderance of the published applications of bioelectrical impedance analysis focused on applications in a healthy population and in the field indicate the validity of the methods. A short description of the set-up of the segmental method is also given. This review discusses the application of segmental bioelectrical impedance analysis in children in different ethnic populations, in clinical situations. We also examine the application of the method to assessing body composition, and monitoring rapid changes in internal fluid balance in the field of haemodialysis and during surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Deurenberg, P., Deurenberg-Yap, M., & Schouten, F. (2002) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601303 · Cited by 87
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
“This might explain the advantage of segmental BIA (trunk or limb BIA).(51) A greater variability of ECW:ICW ratio may be responsible for the lower accuracy of BIA and the greater contribution of weight to the unexplained variance of total FFM and FFMleg in anorexia nervosa(33) and cachexia.”
BackgroundInfluentialBioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Campa, F., Toselli, S., Mazzilli, M., Gobbo, L. A., & Coratella, G. (2021) · Nutrients · doi:10.3390/nu13051620 · Cited by 315
“These perplexities have pushed researchers to develop specific equations [24–26] or use alternative evaluation approaches [31,45,56,78,109,110].”
BackgroundMethodContemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Body composition: Why, when and for who?
Thibault, R., Genton, L., & Pichard, C. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2011.12.011 · Cited by 251
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“Depending on the device and whether the aim is to obtain whole-body or segmental measurements, adhesive electrodes may be placed in a standard wrist-ankle tetrapolar arrangement on the hand and the foot of one side of the body, on both sides of the body on both limbs using an 8-electrode arrangement, or on different s…”
Future lines of research on phase angle: Strengths and limitations
Bellido, D., García-García, C., Talluri, A., Lukaski, H. C., & García-Almeida, J. M. (2023) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-023-09803-7 · Cited by 209
“), skeletal muscle assessment in healthy subjects and individuals with altered muscle mass such as sarcopenia or cancer [25, 26].”
BackgroundAnalysis of Body Composition: A Critical Review of the Use of Bioelectrical Impedance Analysis
Mialich, M. S., Sicchieri, J. M. F., & Jordão, A. A. (2014) · doi:10.12691/ijcn-2-1-1 · Cited by 202
“In a detailed review, De Lorenzo and Andreoli [53] proposed that the trunk, with its large crosswise section, contributes as little as 10% of whole body impedance, which represents 50% of the entire body mass [54].”
BackgroundYamada, Y., Nishizawa, M., Uchiyama, T., Kasahara, Y., Shindo, M., Miyachi, M., & Tanaka, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14070809 · Cited by 190
“Bioelectrical impedance analysis (BIA) is inexpensive, easy to use, portable, and requires no radiation exposure [10-24].”
BackgroundHanamatsu, H., Ohnishi, S., Sakai, S., Yuyama, K., Mitsutake, S., Takeda, H., Hashino, S., & Igarashi, Y. (2014) · Nutrition & Diabetes · doi:10.1038/nutd.2014.38 · Cited by 184
Son, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Validity and accuracy of regional bioelectrical impedance devices to determine whole-body fatness
Lukaski, H. C., & Siders, W. A. (2003) · Nutrition · doi:10.1016/s0899-9007(03)00166-7 · Cited by 73
Differences between the sexes in athletes� body composition and lower limb bioimpedance values
Mascherini, G. (2017) · Muscles, Ligaments and Tendons Journal · doi:10.11138/mltj/2017.7.4.573 · Cited by 43
Integrated Total Body Composition and Localized Fat-Free Mass Assessment
Mascherini, G., Petri, C., & Galanti, G. (2015) · Sport Sciences for Health · doi:10.1007/s11332-015-0228-y · Cited by 39
“With the localized assessment being a vector evaluation, the parameters analyzed were Rz (X) and Xc (X), normalized by segment length [25] (L, X/m), not by height of subject [24]: Thigh: from great trochanter to joint space of the knee; Leg: from joint space of the knee to external malleolus.”
BackgroundMethodBody Composition During Pregnancy: Longitudinal Changes and Method Comparisons
Bosaeus, M., Andersson-Hall, U., Andersson, L., Karlsson, T., Ellegård, L., & Holmäng, A. (2020) · Reproductive Sciences · doi:10.1007/s43032-020-00141-6 · Cited by 28
Campa, F., Bongiovanni, T., Rossi, A., Cerullo, G., Casolo, A., Martera, G., Trecroci, A., Moro, T., & Paoli, A. (2023) · Journal of Translational Medicine · doi:10.1186/s12967-023-04795-z · Cited by 15
“Although the simplest way to analyse body composition is to consider body mass as the sum of fat mass and fat-free mass (FFM), the quantification of smallest FFM components allows for a higher accuracy through a compartmental-based assessment [3].”
Method
Metadata
- Authors
- Lorenzo, A. D., & Andreoli, A.
- Venue
- Current Opinion in Clinical Nutrition and Metabolic Care
- Published
- 2003-09
- Volume
- 6
- Issue
- 5
- Pages
- 551-555
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W1989951170
- Cited by
- 69
- References
- 2
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.