Task Force III: Target-organ damage, morbidity and mortality
The DOI matches its Crossref record.
Abstract
Objective To reach a consensus on ambulatory blood pressure (ABP) as a predictor of target-organ damage (TOD), morbidity and mortality. Method The members of task force III wrote this article in preparation for the Seventh International Consensus Conference (23–25 September 1999). This article was amended after the meeting to reflect the consensus reached at the conference. Points of consensus In most studies, TOD in essential hypertension was more closely associated with ABP than it was with clinic blood pressure, the mean weighted correlation coefficients for the relationship of left ventricular mass with blood pressure being 0.50/0.44 (24 h systolic/diastolic blood pressure) and 0.35/0.32 (clinic systolic/diastolic blood pressure), respectively. The above correlation coefficients vary among studies, possibly because of different standardizations of clinic blood pressure measurements and ways of selecting subjects, among other reasons. The closeness of the association between clinic blood pressure and left ventricular mass increases with the numbers of clinic measurements of blood pressure and visits to a clinic. Thus, the variance of left ventricular mass explained by ABP in addition to that explained by clinic blood pressure diminishes with the number of clinic blood pressure readings. The proportion of variability of left ventricular mass that is directly accounted for by the day-night difference in blood pressure is 15% at the most. Thus, the advantage of ABP over clinic blood pressure appears to be, at least in part, a result of the greater number of measurements over the 24 h. It might also depend, however, on the information offered by ambulatory blood pressure monitoring (ABPM) on daily-life variations in blood pressure. TOD appears to be more closely associated with ABP than it is with clinic blood pressure for the subjects with reproducible ABP tracings, but not for those with poorly reproducible tracings. The probability of developing sustained clinic hypertension at follow-up seems to be better predicted by clinic blood pressure on several occasions over a 6-month period than it is by ABP at baseline, although, when also ABPM is repeatedly performed at follow-up, its ability to predict clinical outcomes of hypertensive patients remains superior to that of repeated clinic blood pressure measurements. ABPM of the elderly appears feasible and is tolerated well. A blunted day-night fall in blood pressure ('non-dipping') seems to be harmful, while evidence regarding the potentially harmful effect of extreme dipping is still limited. Authors of the Syst-Eur study recently demonstrated the prognostic value of ambulatory systolic blood pressure and in particular, of night-time blood pressure, in assessing old subjects with isolated systolic hypertension. The assessment of variability of blood pressure has been shown to provide a further prediction of cardiovascular risk and the potentially prognostic value of beat-to-beat variability assessed non-invasively (using a Finapres or Portapres device) needs further study. In the published event-based studies, the prognostic value of ABP recorded during a single session was superior to that of clinic blood pressure. Since the authors of published event-based prognostic studies compared ABP with only a few clinic measurements of blood pressure, it is not known how many visits or measurements of blood pressure (and at what cost) would equate to a single session of ABPM in terms of prediction of cardiovascular events. ABPM might allow one to identify a subset with 'normal' ABP (white-coat or isolated clinic hypertension). Daytime ABP levels < 135 mmHg systolic and 85 mmHg diastolic can be defined as normal and values < 130/80 mmHg could be defined as optimal. Cardiovascular risk for subjects with normal ABP seems to be lower than that for those with abnormally high ABP. Long-term observational and intervention studies concerning subjects with white-coat hypertension are needed. Among subjects with abnormally high ABP, cardiovascular risk seems to be inversely associated with the day-night difference in blood pressure and directly associated with ambulatory pulse pressure. The potential additional prognostic value of self-measured blood pressure needs further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationMobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Twenty-four-hour ambulatory blood pressure in children with sleep-disordered breathing
Amin, R. S., Carroll, J. L., Jeffries, J. L., Grone, C., Bean, J. A., Chini, B., Bokulic, R., & Daniels, S. R. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200309-1305oc · Cited by 354
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Bliziotis, I. A., Destounis, A., & Stergiou, G. S. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283531eaf · Cited by 261
Metadata
- Authors
- Verdecchia, P., Clement, D., Fagard, R., Palatini, P., & Parati, G.
- Venue
- Blood Pressure Monitoring
- Published
- 1999-12
- Volume
- 4
- Issue
- 6
- Pages
- 303-318
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2082281669
- Cited by
- 74
- References
- 0
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Task Force III: Target-organ damage, morbidity and mortality. https://app.cochat.ai/papers/10.1097/00126097-199900460-00004
- The paper
- Verdecchia, P., Clement, D., Fagard, R., Palatini, P., & Parati, G. (1999). Task Force III: Target-organ damage, morbidity and mortality. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-199900460-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.