CoChat

Twenty-four-hour ambulatory blood pressure monitoring in atrial fibrillation

Olsen, Roy, Amlie, Aina, Omvik, Per · 2002 · Blood Pressure Monitoring
Cited by 29

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Due to large beat-to-beat blood pressure variation the use of 24-h ambulatory blood pressure monitoring in patients with atrial fibrillation has been questioned. METHODS: Repeatability and variability of 24-h ambulatory blood pressure (Accutraccer II or Diasys Integra), and daily blood pressure variation was examined in 42 patients aged 51-81 (median 73.5) years admitted for elective electrocardioversion of atrial fibrillation. RESULTS: Before cardioversion 24-h ambulatory systolic blood pressure was slightly lower and nocturnal blood pressure reduction was larger in the group of patients who achieved sinus rhythm than in the group who maintained atrial fibrillation (11.5/10.5 versus 4.1/4.7 mmHg; P < 0.05). No statistically significant change was observed in ambulatory blood pressure after cardioversion in any of the two groups. Blood pressure variability (SD/mean) was 10-14% both in patients with and without conversion to sinus rhythm. Coefficient of repeatability (2 SD of difference) was 13.6 mmHg (16.6%) for diastolic blood pressure and 30.2 mmHg (24.7%) for systolic blood pressure in patients with normalized heart rhythm and 17.0 and 29.0 mmHg (21.5 and 22.4%) in patients with maintained atrial fibrillation, respectively. CONCLUSION: Ambulatory blood pressure monitoring provides data with similar variability and repeatability in patients with atrial fibrillation as in subjects with normal cardiac rhythm. Twenty-four-hour ambulatory blood pressure measurement is applicable in atrial fibrillation in the same way as during sinus rhythm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200206000-00002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 29

Metadata

Authors
Olsen, R., Amlie, A., & Omvik, P.
Venue
Blood Pressure Monitoring
Published
2002-06
Volume
7
Issue
3
Pages
149-156
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2332242247
Cited by
29
References
1
FWCI
0.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Twenty-four-hour ambulatory blood pressure monitoring in atrial fibrillation. https://app.cochat.ai/papers/10.1097/00126097-200206000-00002
The paper
Olsen, R., Amlie, A., & Omvik, P. (2002). Twenty-four-hour ambulatory blood pressure monitoring in atrial fibrillation. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200206000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.